Dental Implants with Conical Implant-Abutment Interface: Influence of the Conical Angle Difference on the Mechanical Behavior of the Implant

被引:22
作者
Aguirrebeitia, Josu [1 ]
Abasolo, Mikel [1 ]
Vallejo, Javier [1 ]
Ansola, Ruben [1 ]
机构
[1] Univ Basque Country, ETSI BILBAO, Dept Mech Engn, Bilbao 48013, Spain
关键词
conical angle difference; conical implant; finite element model; sensitivity study; FINITE-ELEMENT-ANALYSIS; IN-VITRO EVALUATION; BACTERIAL LEAKAGE; PROSTHESIS; COMPONENTS; SYSTEM; DOGS; FIT;
D O I
10.11607/jomi.2775
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Misfit in the conical implant-abutment interface plays an important role on the mechanical behavior of the implant when masticatory forces are applied. The origin of the misfit adopted in this work is a conical angle difference between implant and abutment, which can be due to a combination of design decisions and manufacturing tolerances. The goal of this work was to investigate the effects of the implant-abutment conical angle difference in the following mechanical features: interfacial microgap, preload loss on the bolt, stress level in the bone, and abutment removal force and/or torque. Materials and Methods: A simplified three-dimensional nonlinear monoparametric finite element model of an OsseoSpeed TX 4.5 S 9-mm implant (Astra Tech) with a tapered implant-abutment interface was built to evaluate the variability of the mechanical features cited above with the conical angle difference, keeping constant the overall geometry, load and boundary conditions, material properties, frictional behavior, and mesh structure. Results: As the conical angle difference increased, the following effects were observed: the microgap decreased and remained almost constant for values over a given positive angle difference, the stress level in the bone increased sensitively, the removal force and/or torque needed to separate the abutment from the implant varied slightly, and the bolt preload loss increased. Conclusions: In light of the results provided, the conical angle difference in the implant-abutment interface had a significant influence on the overall mechanical behavior of the implant. Among the four mechanical features considered, the interfacial microgap and the bone stress were demonstrated to be the most sensitive to the conical angle difference, and therefore the most relevant when selecting an optimum value in the design process of a conical interface.
引用
收藏
页码:E72 / E82
页数:11
相关论文
共 50 条
[31]   In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems [J].
Steinebrunner, L ;
Wolfart, S ;
Bössmann, K ;
Kern, M .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (06) :875-881
[32]   Systemic observation and measurement of microgap formation in dental implant-abutment connection interface under fatigue [J].
Mercan, Cigdem ;
Bulutsuz, Asli Gunay ;
Katiboglu, Ahmet Bulent .
MATERIALS TESTING, 2023, 65 (11) :1679-1685
[33]   The Role of Chlorhexidine on Endotoxin Penetration to the Implant-Abutment Interface (IAI) [J].
Koutouzis, Theofilos ;
Gadalla, Hana ;
Kettler, Zachary ;
Elbarasi, Amelsaad ;
Nonhoff, Joerg .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (03) :476-482
[34]   Bacterial Leakage in Implants With Different Implant-Abutment Connections: An In Vitro Study [J].
Assenza, Bartolomeo ;
Tripodi, Domenico ;
Scarano, Antonio ;
Perrotti, Vittoria ;
Piattelli, Adriano ;
Iezzi, Giovanna ;
D'Ercole, Simonetta .
JOURNAL OF PERIODONTOLOGY, 2012, 83 (04) :491-497
[35]   Leakage of Saliva Through the Implant-Abutment Interface: In Vitro Evaluation of Three Different Implant Connections Under Unloaded and Loaded Conditions [J].
do Nascimento, Cassio ;
Miani, Paola Kirsten ;
Pedrazzi, Vinicius ;
Goncalves, Reginaldo Bruno ;
Ribeiro, Ricardo Faria ;
Lapria Faria, Adriana Claudia ;
Macedo, Ana Paula ;
Albuquerque Junior, Rubens Ferreira de .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (03) :551-560
[36]   Influence of Methodologic Aspects on the Results of Implant-Abutment Interface Microleakage Tests: A Critical Review of In Vitro Studies [J].
da Silva-Neto, Joao Paulo ;
de Arruda Nobilo, Mauro Antonio ;
Amante Penatti, Mario Paulo ;
Simamoto, Paulo Cezar, Jr. ;
das Neves, Flavio Domingues .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (04) :793-800
[37]   Effect of the Coronal Wall Thickness of Dental Implants on the Screw Joint Stability in the Internal Implant-Abutment Connection [J].
Lee, Ji-Hye ;
Huh, Yoon-Hyuk ;
Park, Chan-Jin ;
Cho, Lee-Ra .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) :1058-1065
[38]   Effect of Implant-Abutment Connection Design on Load Bearing Capacity and Failure Mode of Implants [J].
Dittmer, Stephanie ;
Dittmer, Marc Philipp ;
Kohorst, Philipp ;
Jendras, Michael ;
Borchers, Lothar ;
Stiesch, Meike .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (07) :510-516
[39]   Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessment [J].
Torres, Jacques-Henri ;
Mechali, Michael ;
Romieu, Olivier ;
Tramini, Paul ;
Callas, Sylvie ;
Cuisinier, Frederic J. G. ;
Levallois, Bernard .
BIOMEDICAL ENGINEERING ONLINE, 2011, 10
[40]   Micro-leakage at the implant-abutment interface with different tightening torques in vitro [J].
da Silva-Neto, Joao Paulo ;
Prudente, Marcel Santana ;
Prado Naves Carneiro, Thiago de Almeida ;
de Arruda Nobilo, Mauro Antonio ;
Amante Penatti, Mario Paulo ;
das Neves, Flavio Domingues .
JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (05) :581-587