Development of dynamic three-dimensional multi-pinhole gamma camera

被引:4
作者
Takemoto, Hisato [1 ]
Watanabe, Kenichi [1 ]
Kawarabayashi, Jun [1 ]
Iguchi, Tetsuo [1 ]
Uritani, Akira [1 ]
机构
[1] Nagoya Univ, Grad Sch Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
multi-pinhole collimator; gamma camera; imaging plate; flat panel detector; dynamic 3-D imaging; ML-EM; SPECT; medical diagnosis;
D O I
10.3327/jnst.43.344
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this paper we propose a dynamic 3-D gamma camera consisting of multi-pinhole collimators and flat panel detectors. Through simulation studies on various pinhole configurations we determined that from a spatial and time resolution consideration, pinhole collimators with a 60 degrees opening angle achieved acceptable dynamic 3-D imaging results. With regard to basic system performance, we estimated that the spatial and time resolution exceeds 3.5 mm and 4 s, respectively, for a small animal injected with Tc-99m with an activity of 37 MBq. In addition, from further experiments we concluded that the proposed system would be acceptable and practical as a dynamic 3-D imager for nuclear medicine applications although position calibration concerns require further study.
引用
收藏
页码:344 / 347
页数:4
相关论文
共 7 条
[1]   PINHOLE COLLIMATION FOR ULTRA-HIGH-RESOLUTION, SMALL-FIELD-OF-VIEW SPECT [J].
JASZCZAK, RJ ;
LI, JY ;
WANG, HL ;
ZALUTSKY, MR ;
COLEMAN, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :425-437
[2]   Performance evaluation of A-SPECT: A high resolution desktop pinhole SPECT system for imaging small animals [J].
McElroy, DP ;
MacDonald, LR ;
Beekman, FJ ;
Wang, YC ;
Patt, BE ;
Iwanczyk, JS ;
Tsui, BMW ;
Hoffman, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2139-2147
[3]   An investigation of coded aperture imaging for small animal SPECT [J].
Meikle, SR ;
Fulton, RR ;
Eberl, S ;
Dahlbom, M ;
Wong, KP ;
Fulham, MJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :816-821
[4]   Flat panel detectors - closing the (digital) gap in chest and skeletal radiology [J].
Reiff, KJ .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) :125-131
[5]   High-resolution SPECT using multipinhole collimation [J].
Schramm, NU ;
Ebel, G ;
Engeland, U ;
Schurrat, T ;
Béhé, M ;
Behr, TM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) :315-320
[6]  
Shepp L A, 1982, IEEE Trans Med Imaging, V1, P113, DOI 10.1109/TMI.1982.4307558
[7]   Development of three-dimensional gamma camera with imaging plates and multi-pinhole collimators [J].
Yamamura, N ;
Uritani, A ;
Watanabe, K ;
Kawarabayashi, J ;
Iguchi, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2) :577-581