Noninvasive continuous arterial pressure monitoring with Clearsight during awake carotid endarterectomy A prospective observational study

被引:20
作者
Noto, Alberto [1 ,2 ]
Sanfilippo, Filippo [3 ]
De Salvo, Giovanni [2 ]
Crimi, Claudia [4 ]
Benedetto, Filippo [5 ]
Watson, Ximena [6 ]
Cecconi, Maurizio [7 ]
David, Antonio [2 ]
机构
[1] CNR, IPCF, Inst Chem & Phys Proc, Messina, Italy
[2] Univ Messina, AOU G Martino, Dept Anaesthesia & Intens Care, Messina, Italy
[3] ISMETT Ist Mediterraneo Trapianti & Terapie Ad Al, IRCCS, Dept Anaesthesia & Intens Care, Palermo, Italy
[4] Univ Catania, AOU Policlin Vittorio Emanuele, Dept Resp Med, Catania, Italy
[5] Univ Messina, AOU G Martino, Dept Vasc Surg, Messina, Italy
[6] St Helier & Epsom Hosp, Dept Anaesthesia & Intens Care, London, England
[7] St Georges Univ Hosp NHS Fdn Trust, Dept Intens Care Med, London, England
关键词
CARDIAC-OUTPUT; BLOOD-PRESSURE; INVASIVE MEASUREMENTS; LOCAL-ANESTHESIA; DEVICE; VALIDATION; PRECISION; AGREEMENT; NEXFIN; RISK;
D O I
10.1097/EJA.0000000000000938
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND Continuous noninvasive blood pressure (CNBP) measurement using the volume-clamp method is a less invasive alternative compared with invasive intra-arterial monitoring for awake patients during carotid endarterectomy (CEA) under regional anaesthesia. OBJECTIVE We investigated the agreement of blood pressure (BP) recorded with invasive and CNBP methods during awake CEA. DESIGN A prospective observational study for assessing agreement with Bland-Altman plots, agreement-tolerability indices (ATI), concordance and interchangeability. SETTING Azienda Ospedaliera Universitaria G. Martino, Messina, a University tertiary referral centre in Italy. PATIENTS In 30 consecutive patients, we recorded continuously ipsilateral invasive and noninvasive BPs, from 3 min before carotid cross-clamping to 5 min after unclamping. MAIN OUTCOME MEASURES Primary outcome was bias, 95% limits of agreement, ATI, concordance and interchangeability for mean arterial pressure (MAP). Secondary outcomes were agreements for systolic arterial pressure and diastolic arterial pressure. Tracking of changes was assessed with four-quadrant polar plots and the trend interchangeability method. Optimal bias was defined as 5 mmHg or less. RESULTS A total of 2672 invasive and CNBP paired measurements (93% of overall data) were analysed, with a median of 92 readings per patient [IQR 76 to 100]. Mean (SD) bias for MAP, systolic arterial pressure and DAP were -6.8 (6.7), -3.0 (9.7) and -9.0 (5.4) mmHg, respectively. The ATIs were 0.88, 0.95 and 0.71, respectively, where ATI of 1.0 or less and at least 2.0 defined acceptable, marginal and unacceptable agreements. The four-quadrant plot analysis for beat-to-beat differences showed concordance rates of 97.3%, 99.98% and 96.4%, respectively. Polar plot analysis showed 95% limits of agreement of -3 to 3, -2 to 2 and -2 to 2 mmHg respectively. Trend interchangeability method showed an interchangeability rate of 95% for MAP. CONCLUSION During CEA performed under regional anaesthesia, CNBP offers a less invasive approach for BP monitoring. We found acceptable agreement for MAP defined by an ATI of 0.88 and an excellent 95% global interchangeability rate. A suboptimal bias of 7 mmHg was found with CNBP for MAP.
引用
收藏
页码:144 / 152
页数:9
相关论文
共 45 条
[1]   Anesthetic type and hospital outcomes after carotid endarterectomy from the Vascular Quality Initiative database [J].
Aridi, Hanaa Dakour ;
Paracha, Nawar ;
Nejim, Besma ;
Locham, Satinderjit ;
Malas, Mahmoud B. .
JOURNAL OF VASCULAR SURGERY, 2018, 67 (05) :1419-1428
[2]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[3]   Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations [J].
Brzezinski, Marek ;
Luisetti, Thomas ;
London, Martin J. .
ANESTHESIA AND ANALGESIA, 2009, 109 (06) :1763-1781
[4]   Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output [J].
Cecconi, Maurizio ;
Rhodes, Andrew ;
Poloniecki, Jan ;
Della Rocca, Giorgio ;
Grounds, R. Michael .
CRITICAL CARE, 2009, 13 (01)
[5]  
Columb MO., 2008, CURR ANAESTH CRIT CA, V19, P328, DOI DOI 10.1016/J.CACC.2008.07.001
[6]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[7]   A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output [J].
Critchley, Lester A. ;
Lee, Anna ;
Ho, Anthony M. -H. .
ANESTHESIA AND ANALGESIA, 2010, 111 (05) :1180-1192
[8]   Stroke from carotid endarterectomy: When and how to reduce perioperative stroke rate? [J].
de Borst, GJ ;
Moll, FL ;
van de Pavoordt, HDWM ;
Mauser, HW ;
Kelder, JC ;
Ackerstaff, RGA .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2001, 21 (06) :484-489
[9]   2014 ESC Guidelines on the diagnosis and treatment of aortic diseases [J].
Erbel, Raimund ;
Aboyans, Victor ;
Boileau, Catherine ;
Bossone, Eduardo ;
Di Bartolomeo, Roberto ;
Eggebrecht, Holger ;
Evangelista, Arturo ;
Falk, Volkmar ;
Frank, Herbert ;
Gaemperli, Oliver ;
Grabenwoeger, Martin ;
Haverich, Axel ;
Iung, Bernard ;
Manolis, Athanasios John ;
Meijboom, Folkert ;
Nienaber, Christoph A. ;
Roffi, Marco ;
Rousseau, Herve ;
Sechtem, Udo ;
Sirnes, Per Anton ;
von Allmen, Regula S. ;
Vrints, Christiaan J. M. .
EUROPEAN HEART JOURNAL, 2014, 35 (41) :2873-U93
[10]   Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery [J].
Fischer, M. O. ;
Avram, R. ;
Carjaliu, I. ;
Massetti, M. ;
Gerard, J. L. ;
Hanouz, J. L. ;
Fellahi, J. L. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (04) :514-521