Thermal Ageing Effect on the Failure Time of Oil-Paper Insulation at Combined AC-DC Voltage

被引:0
|
作者
Tao, Fengbo [1 ]
Li, Jiansheng [1 ]
Wei, Chao [1 ]
Li, Yuanlong [2 ]
Zhang, Jing [2 ]
机构
[1] Jiangsu Elect Power Co, Res Inst, Power Equipment Condit Assessment Ctr, Nanjing, Jiangsu, Peoples R China
[2] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Sch Elect Engn, Chongqing, Peoples R China
来源
2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC) | 2016年
关键词
converter transformer; oil-paper insulation; combined AC-DC voltage; thermal aging; breakdown voltage; failure time; ELECTRICAL BREAKDOWN; STRENGTH;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The oil-paper insulation of converter transformer withstands a long time electrical aging by combined AC-DC voltage and thermal aging during operation. The aging failure mode of converter transformers insulation exhibits a great difference with that of AC transformers. In this paper, a set of accelerated thermal aging experiments at 130 degrees C were designed, oil-paper specimens were aged for 5, 10, 20 and 35 days, respectively. The unaged oil-paper specimens were also prepared for comparison. The breakdown voltage and failure time of oil-paper specimens of different aging times at AC and combined AC-DC voltage were measured, respectively. The relationship between the failure time and aging time is obtained by using Weibull analysis method. The experiment results show that the breakdown voltage of oil-paper specimens all decrease not much with the increase of thermal aging time. The oil-paper specimens have a longer failure time at combined AC-DC voltage compared with that at AC voltage.
引用
收藏
页码:284 / 287
页数:4
相关论文
共 50 条
  • [1] Surface flashover characteristics of oil-paper insulation under combined AC-DC voltage
    Zhou, Yuanxiang
    Jin, Fubao
    Sun, Qinghua
    Sha, Yanchao
    Huang, Meng
    PROCEEDINGS OF THE 2013 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2013), VOLS 1 AND 2, 2013, : 1005 - 1008
  • [2] The Electric Field Distribution in Oil-paper Insulation under Combined AC-DC Voltage
    Wu, Hao
    Li, ChengRong
    Qi, Bo
    Zhao, XiaoLin
    Lv, JinZhuang.
    Zhao, LinJie
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 1097 - 1101
  • [3] Partial Discharge Characteristics in Oil-paper Insulation under Combined AC-DC Voltage
    Sha, Yanchao
    Zhou, Yuanxiang
    Li, Jinzhong
    Wang, Jianyi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) : 1529 - 1539
  • [4] Effect of DC component on characteristics of surface discharge process in oil-paper insulation under combined AC-DC voltage
    Jin, Fubao
    Zhou, Yuanxiang
    Li, Guangfan
    Huang, Meng
    Liu, Zehong
    Huang, Jianwen
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (09): : 3082 - 3090
  • [5] Measurement and simulation of partial discharge in oil-paper insulation under the combined AC-DC voltage
    Sha, Yanchao
    Zhou, Yuanxiang
    Zhang, Ling
    Huang, Meng
    Jin, Fubao
    JOURNAL OF ELECTROSTATICS, 2013, 71 (03) : 540 - 546
  • [6] Characteristics of the surface discharge process in oil-paper insulation under combined AC-DC voltage
    Jin, Fubao
    Zhou, Yuanxiang
    Liu, Zehong
    Huang, Meng
    Lu, Licheng
    Sha, Yanchao
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (06): : 1965 - 1973
  • [7] Influence of Aging on Creepage Discharge Characteristics of Oil-Paper Insulation Under AC-DC Combined Voltage
    Jin Fubao
    Zhou Yuanxiang
    Liang Bin
    IEEE ACCESS, 2021, 9 : 49016 - 49024
  • [8] Surface Flashover Phenomenon of Aged Oil-paper Insulation Induced by DC Voltage Preloading Under the Combined AC-DC Voltage
    Jin F.
    Zhou Y.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (10): : 4421 - 4428
  • [9] Effect of Electric-Field Components on the Flashover Characteristics of Oil-Paper Insulation Under Combined AC-DC Voltage
    Jin, Fubao
    Zhou, Yuanxiang
    IEEE ACCESS, 2023, 11 : 556 - 563
  • [10] Influence of Temperature on Developing Process of Surface Flashover in Oil-Paper Insulation under Combined AC-DC Voltage
    Zhou, Yuanxiang
    Jin, Fubao
    Huang, Meng
    Sha, Yanchao
    Zhang, Ling
    Huang, Jianwen
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 486 - 489