Highly sensitive hydrogen peroxide sensor based on a glassy carbon electrode modified with platinum nanoparticles on carbon nanofiber heterostructures

被引:23
|
作者
Yang, Yang [1 ]
Fu, Renzhong [1 ]
Yuan, Jianjun [1 ]
Wu, Shiyuan [1 ]
Zhang, Jialiang [1 ]
Wang, Haiying [1 ]
机构
[1] Changshu Inst Technol, Dept Chem, Jiangsu Lab Adv Funct Mat, Changshu 215500, Peoples R China
基金
中国国家自然科学基金;
关键词
Platinum nanoparticles; Heterostructure; Carbon nanofiber; H2O2; sensor; Hydrogen peroxide; GLUCOSE; COMPOSITE; POLYACRYLONITRILE; PERFORMANCE; BIOSENSOR; ELECTROCATALYST; FABRICATION; CATALYST; H2O2;
D O I
10.1007/s00604-015-1558-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We are presenting a sensor for hydrogen peroxide (H2O2) that is based on the use of a heterostructure composed of Pt nanoparticles (NPs) and carbon nanofibers (CNFs). High-density Pt NPs were homogeneously loaded onto a three-dimensional nanostructured CNF matrix and then deposited in a glassy carbon electrode (GCE). The resulting sensor synergizes the advantages of the conducting CNFs and the nanoparticle catalyst. The porous structure of the CNFs also favor the high-density immobilization of the NPs and the diffusion of water-soluble molecules, and thus assists the rapid catalytic oxidation of H2O2. If operated at a working voltage of -0.2 V (vs. Ag/AgCl), the modified GCE exhibits a linear response to H2O2 in the 5 mu M to 15 mM concentration range (total analytical range: 5 mu M to 100 mM), with a detection limit of 1.7 mu M (at a signal-to-noise ratio of 3). The modified GCE is not interfered by species such as uric acid and glucose. Its good stability, high selectivity and good reproducibility make this electrode a valuable tool for inexpensive amperometric sensing of H2O2.
引用
收藏
页码:2241 / 2249
页数:9
相关论文
共 50 条
  • [1] Highly sensitive hydrogen peroxide sensor based on a glassy carbon electrode modified with platinum nanoparticles on carbon nanofiber heterostructures
    Yang Yang
    Renzhong Fu
    Jianjun Yuan
    Shiyuan Wu
    Jialiang Zhang
    Haiying Wang
    Microchimica Acta, 2015, 182 : 2241 - 2249
  • [2] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Wang, Ai-Jun
    Zhang, Pei-Pei
    Li, Yong-Fang
    Feng, Jiu-Ju
    Dong, Wen-Ju
    Liu, Xue-Yan
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 31 - 37
  • [3] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jin, Jiayi
    Wu, Wenqin
    Min, Hui
    Wu, Huimin
    Wang, Shengfu
    Ding, Yu
    Yang, Shuijin
    MICROCHIMICA ACTA, 2017, 184 (05) : 1389 - 1396
  • [4] A sensitive nonenzymatic hydrogen peroxide sensor using cadmium oxide nanoparticles/multiwall carbon nanotube modified glassy carbon electrode
    Butwong, Nutthaya
    Zhou, Lin
    Ng-Eontae, Wittaya
    Burakham, Rodjana
    Moore, Eric
    Srijaranai, Supalax
    Luong, John H. T.
    Glennon, Jeremy D.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 717 : 41 - 46
  • [5] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [6] Fabrication of CaTiO3 modified glassy carbon electrode-based hydrogen peroxide sensor
    Ahmad, Khursheed
    Niyitanga, Theophile
    Pathak, Aarti
    Khan, Rais Ahmad
    Khan, Mohd Quasim
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2024, 21 (08) : 2147 - 2157
  • [7] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Ai-Jun Wang
    Pei-Pei Zhang
    Yong-Fang Li
    Jiu-Ju Feng
    Wen-Ju Dong
    Xue-Yan Liu
    Microchimica Acta, 2011, 175 : 31 - 37
  • [8] An ultra-sensitive non-enzymatic hydrogen peroxide sensor based on SiO2-APTES supported Au nanoparticles modified glassy carbon electrode
    Bayram, Lutfullah
    Guler, Muhammet
    PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2019, 29 (04) : 390 - 396
  • [9] An Amperometric Sensitive Hydrogen Peroxide Sensor Based on a Silver Nanoparticle-Doped Polyimide-Modified Glassy Carbon Electrode
    Chen, Lin
    Wang, Yue
    Ban, Hao
    Yu, Simin
    Tao, Dongping
    Hu, Zhizhi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11): : 10961 - 10972
  • [10] A Novel Hydrogen Peroxide Sensor Based on Multiwalled Carbon Nanotubes/Poly(pyrocatechol violet)-Modified Glassy Carbon Electrode
    Fang, Bin
    Zhang, Na
    Zhang, Wei
    Gu, Aixia
    Wang, Guangfeng
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 112 (06) : 3488 - 3493