Optimal working state tracking method and experiments on inductive contactless power transmission system

被引:1
|
作者
Huo, Fangqiang [1 ]
Li, Yansong [1 ]
Wan, Jun [1 ]
Wang, Minhao [1 ]
Liu, Jun [1 ]
机构
[1] North China Elect Power Univ, Sch Elect & Elect Engn, Beijing 102206, Peoples R China
关键词
inductive power transmission; photovoltaic power systems; maximum power point trackers; digital control; power generation control; compensation; optimisation; perturbation techniques; optimal point; tracking accuracy; improved perturb-observe method; component drift parametric scanning; inductive contactless power transmission system; output voltage; reasonable working frequency band; optimal working state; traditional frequency tracking;
D O I
10.1049/iet-pel.2019.1248
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To address the problems of traditional frequency tracking, such as falling into a local optimum, oscillation near the optimal point, and contradiction between tracking speed and tracking accuracy, an improved perturb-observe method based on component drift parametric scanning is proposed. An inductive contactless power transmission system with LCC/S third-order compensation topology is employed as the research object. First, the relationships between the output voltage and frequency under component drift parametric scanning are given by theoretical deduction and calculation. Then, a reasonable working frequency band is intercepted, and the improved perturb-observe method (including start, end, step, and anti-death cycle judgement) is used to track the optimal working state adaptively. Finally, the correctness of the proposed theory and method was verified by simulations and physical experiments.
引用
收藏
页码:2562 / 2568
页数:7
相关论文
共 50 条
  • [1] Inductive coupler for contactless power transmission
    Sergeant, P.
    Van den Bossche, A.
    IET ELECTRIC POWER APPLICATIONS, 2008, 2 (01) : 1 - 7
  • [2] Frequency selection of an inductive contactless power transmission system for ocean observing
    Zhou, Jie
    Li, De-jun
    Chen, Ying
    OCEAN ENGINEERING, 2013, 60 : 175 - 185
  • [3] A New Maximum Inductive Power Transmission Capacity Tracking Method
    Ameri, Mohammad Hassan
    Varjani, Ali Yazdian
    Mohamadian, Mustafa
    JOURNAL OF POWER ELECTRONICS, 2016, 16 (06) : 2202 - 2211
  • [4] On Piecewise Control Method of Contactless Power Transmission System
    Chen Guodong
    Sun Yue
    Dai Xin
    Wang Zhihui
    PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 7, 2008, : 72 - 75
  • [5] Optimal Design of the Coupled Structure of Undersea Contactless Power Transmission System
    Gao, Qifeng
    Li, Zesong
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON INFORMATION SCIENCES, MACHINERY, MATERIALS AND ENERGY (ICISMME 2015), 2015, 126 : 1320 - 1324
  • [6] Optimal Operation Point Tracking Control for Inductive Power Transfer System
    Zhao, Tiefu
    Pahl, Birger
    Xu, Jun
    Wu, Bruce
    Nirantare, Prasanna
    Kothekar, Milind
    2015 IEEE WIRELESS POWER TRANSFER CONFERENCE (WPTC), 2015,
  • [7] Performance Analysis of an Inductive Contactless Power Transfer System
    Amirat, Yassine
    Feld, Gilles
    Auffret, Yves
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 3918 - 3923
  • [8] A Sensitivity Study on an Inductive Contactless Power Transfer System
    Sorbu, Ioana-Gabriela
    IEEE EUROCON 2015 - INTERNATIONAL CONFERENCE ON COMPUTER AS A TOOL (EUROCON), 2015, : 296 - 301
  • [9] Contactless inductive power pickup system for Maglev applications
    Song, BM
    Kratz, R
    Gurol, S
    CONFERENCE RECORD OF THE 2002 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2002, : 1586 - 1591
  • [10] A study on power transmission system using resonant frequency tracking method and contactless transformer with multiple primary winding
    Rho, Sung-Chan
    Kim, Soo-Hong
    Ahn, Young-Hoon
    Kim, Baik
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-4, 2007, : 1834 - 1838