Lineal energy and radiation quality in radiation therapy: model calculations and comparison with experiment

被引:56
作者
Lindborg, L. [1 ]
Hultqvist, M. [2 ]
Tedgren, A. Carlsson [3 ,4 ]
Nikjoo, H. [1 ]
机构
[1] Karolinska Inst, Dept Oncol Pathol, Radiat Biophys Grp, SE-17176 Stockholm, Sweden
[2] Stockholm Univ, Dept Phys, SE-17177 Stockholm, Sweden
[3] Linkoping Univ, Fac Hlth Sci, Dept Med & Hlth Sci IMH, SE-58185 Linkoping, Sweden
[4] Swedish Radiat Safety Author, SE-17116 Stockholm, Sweden
关键词
VARIANCE-COVARIANCE METHOD; NEUTRON THERAPY; ION; MICRODOSIMETRY; BEAMS; RBE; ELECTRONS; NANODOSIMETRY; SPECIFICATION; RADIOTHERAPY;
D O I
10.1088/0031-9155/58/10/3089
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Microdosimetry is a recommended method for characterizing radiation quality in situations when the biological effectiveness under test is not well known. In such situations, the radiation beams are described by their lineal energy probability distributions. Results from radiobiological investigations in the beams are then used to establish response functions that relate the lineal energy to the relative biological effectiveness (RBE). In this paper we present the influence of the size of the simulated volume on the relation to the clinical RBE values (or weighting factors). A single event probability distribution of the lineal energy is approximated by its dose average lineal energy ((y) over bar (D)) which can be measured or calculated for volumes from a few micrometres down to a few nanometres. The clinical RBE values were approximated as the ratio of the alpha-values derived from the LQ-relation. Model calculations are presented and discussed for the SOBP of a C-12 ion (290 MeV u(-1)) and the reference Co-60 gamma therapy beam. Results were compared with those for a conventional x-ray therapy beam, a 290 MeV proton beam and a neutron therapy beam. It is concluded that for a simulated volume of about 10 nm, the alpha-ratio increases approximately linearly with the (y) over bar (D)-ratio for all the investigated beams. The correlation between y and alpha provides the evidence to characterize a radiation therapy beam by the lineal energy when, for instance, weighting factors are to be estimated.
引用
收藏
页码:3089 / 3105
页数:17
相关论文
共 51 条
[1]  
[Anonymous], 1970, Report 16
[2]   DOSE-EFFECT RELATIONS FOR TUMOR-CONTROL AND COMPLICATION RATE AFTER FAST-NEUTRON THERAPY FOR PELVIC TUMORS [J].
BATTERMANN, JJ ;
HART, GAM ;
BREUR, K .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (646) :899-904
[3]   THE VARIANCE-COVARIANCE METHOD - MICRODOSIMETRY IN TIME-VARYING LOW DOSE-RATE RADIATION-FIELDS [J].
BRECKOW, J ;
WENNING, A ;
ROOS, H ;
KELLERER, AM .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1988, 27 (04) :247-259
[4]   The linear-quadratic model is an appropriate methodology for determining isoeffective doses at large doses per fraction [J].
Brenner, David J. .
SEMINARS IN RADIATION ONCOLOGY, 2008, 18 (04) :234-239
[5]   Applications of amorphous track models in radiation biology [J].
Cucinotta, FA ;
Nikjoo, H ;
Goodhead, DT .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1999, 38 (02) :81-92
[6]   Microdosimetric investigation at the therapeutic proton beam facility of CATANA [J].
De Nardo, L ;
Moro, D ;
Colautti, P ;
Conte, V ;
Tornielli, G ;
Cuttone, G .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :681-686
[7]   Microdosimetric evaluation of secondary particles in a phantom produced by carbon 290 MeV/nucleon ions at HIMAC [J].
Endo, Satoru ;
Takada, Masashi ;
Onizuka, Yoshihiko ;
Tanaka, Kenichi ;
Maeda, Naoko ;
Ishikawa, Masayori ;
Miyahara, Nobuyuki ;
Hayabuchi, Naofumi ;
Shizuma, Kiyoshi ;
Hoshi, Masaharu .
JOURNAL OF RADIATION RESEARCH, 2007, 48 (05) :397-406
[8]   EXPERIMENTAL LIMITATIONS IN MICRODOSIMETRY MEASUREMENTS USING THE VARIANCE TECHNIQUE [J].
FORSBERG, B ;
LINDBORG, L .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1981, 19 (02) :125-135
[9]   Calculation of stopping power ratios for carbon ion dosimetry [J].
Geithner, O ;
Andreo, P ;
Sobolevsky, N ;
Hartmann, G ;
Jäkel, O .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (09) :2279-2292
[10]   Heavy ion RBE and microdosimetric spectra [J].
Gerlach, R ;
Roos, H ;
Kellerer, AM .
RADIATION PROTECTION DOSIMETRY, 2002, 99 (1-4) :413-418