Electrochemical sensor for enzymatic lactate detection based on laser-scribed graphitic carbon modified with platinum, chitosan and lactate oxidase

被引:38
作者
Madden, Julia [1 ]
Vaughan, Eoghan [1 ]
Thompson, Michael [2 ]
O' Riordan, Alan [1 ]
Galvin, Paul [1 ]
Iacopino, Daniela [1 ]
Teixeira, Sofia Rodrigues [1 ]
机构
[1] Univ Coll Cork, Tyndall Natl Inst, Cork, Ireland
[2] Univ Toronto, Dept Chem, Toronto, ON, Canada
基金
爱尔兰科学基金会; 欧盟地平线“2020”;
关键词
Laser scribed graphitic carbon; Electrochemical biosensors; Lactate oxidase; Lactate sensing; Bendable substrates; CYCLIC VOLTAMMETRY; BLOOD LACTATE; ELECTRODES; BIOSENSOR;
D O I
10.1016/j.talanta.2022.123492
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed a flexible laser scribed graphitic carbon based lactate biosensor fabricated using a low cost 450 nm laser. We demonstrated a facile fabrication method involving electrodeposition of platinum followed by two casting steps for modification with chitosan and lactate oxidase. The biosensor demonstrated chronoamperometric lactate detection within a linear range from 0.2 mM to 3 mM, (R-2 > 0.99), with a limit of detection of 0.11 mM and a sensitivity of 35.8 mu A/mM/cm(2). The biosensor was successful in performing up to 10 consecutive measurements (one after the other) indicating good working stability (RSD <5%). Concerning storage stability, there was no decrease in signal response after 30 days of storage at 4 degrees C. Additionally, we demonstrate enzymatic lactate detection whilst the flexible polyimide substrates were fixed at a curvature (K) of 0.14 mm 1. No noticeable change in signal response was observed in comparison to calibrations obtained at a curvature of 0 mm 1, signifying potential opportunities for sensor attachment or integration with oral-care products such as mouth swabs. Both laser scribed graphitic carbon and Ag/AgCl modified-laser scribed graphitic carbon were successful as reference electrodes for chronoamperometric lactate measurements. Furthermore, using a three-electrode configuration on polyimide, lactate detection in both artificial saliva and sterile human serum samples was achieved for two spiked concentrations (0.5 mM and 1 mM).
引用
收藏
页数:8
相关论文
共 39 条
[21]   Highly Efficient Laser Scribed Graphene Electrodes for On-Chip Electrochemical Sensing Applications [J].
Nayak, Pranati ;
Kurra, Narendra ;
Xia, Chuan ;
Alshareef, Husam N. .
ADVANCED ELECTRONIC MATERIALS, 2016, 2 (10)
[22]   THEORY AND APPLICATION OF CYCLIC VOLTAMMETRY FOR MEASUREMENT OF ELECTRODE REACTION KINETICS [J].
NICHOLSON, RS .
ANALYTICAL CHEMISTRY, 1965, 37 (11) :1351-+
[23]   Investigation of Flexible Arrayed Lactate Biosensor Based on Copper Doped Zinc Oxide Films Modified by Iron-Platinum Nanoparticles [J].
Nien, Yu-Hsun ;
Kang, Zhi-Xuan ;
Su, Tzu-Yu ;
Ho, Chih-Sung ;
Chou, Jung-Chuan ;
Lai, Chih-Hsien ;
Kuo, Po-Yu ;
Lai, Tsu-Yang ;
Dong, Zhe-Xin ;
Chen, Yung-Yu ;
Huang, Yu-Hao .
POLYMERS, 2021, 13 (13)
[24]  
Oprescu Stephanie N., GEODERMA, V23, P100993, DOI [10.1016/j.isci.2020.100993, DOI 10.1016/J.GEODERMA.2020.114704]
[25]   Microscale Biosensor Array Based on Flexible Polymeric Platform toward Lab-on-a-Needle: Real-Time Multiparameter Biomedical Assays on Curved Needle Surfaces [J].
Park, Jaeho ;
Sempionatto, Juliane R. ;
Kim, Jayoung ;
Jeong, Yongrok ;
Gu, Jimin ;
Wang, Joseph ;
Park, Inkyu .
ACS SENSORS, 2020, 5 (05) :1363-1373
[26]   Printed, Flexible Lactate Sensors: Design Considerations Before Performing On-Body Measurements [J].
Payne, Margaret E. ;
Zamarayeva, Alla ;
Pister, Veronika, I ;
Yamamoto, Natasha A. D. ;
Arias, Ana Claudia .
SCIENTIFIC REPORTS, 2019, 9 (1)
[27]   Development of a disposable biosensor for lactate monitoring in saliva [J].
Petropoulos, Konstantinos ;
Piermarini, Silvia ;
Bernardini, Sergio ;
Palleschi, Giuseppe ;
Moscone, Danila .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 237 :8-15
[28]  
RANDLES JEB, 1948, T FARADAY SOC, V44, P327, DOI 10.1039/tf9484400327
[29]   Micromachined sensor for lactate monitoring in saliva [J].
Schabmueller, CGJ ;
Loppow, D ;
Piechotta, G ;
Schütze, B ;
Albers, J ;
Hintsche, R .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (09) :1770-1776
[30]  
Segarra Marta, ENERGY BUILDINGS, V44, P393, DOI [10.1001/jama.2020.17025, DOI 10.1016/J.ENBUILD.2020.109964, 10.1016/j.tins.2020.12.002]