Turbulent flow chromatography in bioanalysis: a review

被引:70
作者
Couchman, Lewis [1 ]
机构
[1] Kings Coll Hosp London, Toxicol Unit, Dept Clin Biochem, London SE5 9RS, England
关键词
turbulent flow chromatography; TurboFlow; LC-MS; MS; high-throughput; automated sample preparation; TANDEM MASS-SPECTROMETRY; SOLID-PHASE EXTRACTION; THROUGHPUT QUANTITATIVE BIOANALYSIS; CONGENITAL ADRENAL-HYPERPLASIA; LYSOSOMAL STORAGE DISORDERS; LIQUID-CHROMATOGRAPHY; ONLINE EXTRACTION; HUMAN PLASMA; SAMPLE PREPARATION; DIRECT-INJECTION;
D O I
10.1002/bmc.2769
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
With advances in fast chromatography techniques, and highly sensitive and selective detection methods such as tandem mass spectrometry, very high-throughput bioanalytical methods can now be easily developed. The bottleneck of the analytical process then becomes the sample preparation, which it is now realized is crucial to the robust operation of the analytical system, especially for quantitative assays. Turbulent flow liquid chromatography was developed in the late 1990s, and combines size exclusion and traditional stationary phase column chemistry to separate macromolecules, such as proteins, from smaller molecules and analytes of interest in biological fluids. By definition, the process is very rapid, and the instrumentation and software have been developed for fully automated, on-line extraction of neat biological fluids. This work aims to review the chromatographic theory of turbulent flow chromatography and illustrate, using examples from recent literature, the application of this technique to a range of analytes from a number of different biological matrices. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:892 / 905
页数:14
相关论文
共 120 条
[1]   Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[2]  
[Anonymous], 2001, Guidance for Industry: Bioanalytical Method Validation
[3]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[4]  
2-Z
[5]  
Belsey SL, 2012, CLIN TOXICOL, V50, P283
[6]   High-throughput chromatographic approaches to liquid chromatographic/tandem mass spectrometric bioanalysis to support drug discovery and development [J].
Berna, MJ ;
Ackermann, BL ;
Murphy, AT .
ANALYTICA CHIMICA ACTA, 2004, 509 (01) :1-9
[7]   Quick screening of priority β-agonists in urine using automated TurboFlow™-LC/Exactive mass spectrometry [J].
Bernsmann, T. ;
Fuerst, P. ;
Godula, M. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (10) :1352-1363
[8]  
Birch MA, 2012, CLIN TOXICOL, V50, P282
[9]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO
[10]  
2-0