Mini invasive hemodynamic monitoring: from arterial pressure to cardiac output

被引:0
作者
Della Rocca, Giorgio [1 ]
Cecconi, Maurizio [1 ]
Costa, Maria Gabriella [1 ]
机构
[1] Univ Udine, Sch Med, Dept Anesthesia & Intens Care Med, I-33100 Udine, Italy
关键词
cardiac output; arterial pressure; stroke volume variation; pulse pressure variation;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To evaluate the Cardiac Output (CO) the standard invasive pulmonary artery catheter (PAC) is considered today the gold standard. The major criticism to the PAC is that its level of invasiveness is not supported by an improvement in patient's outcome. The interest to lesser and lesser invasive techniques is high. Therefore, the alternative techniques have been recently developed. Cardiac Output can be monitored continuously by different devices that analyze the arterial waveform to track changes in stroke volume (SV) and CO. The analysis of the arterial pressure wave to determine cardiac output is classified as Pulse Contour analysis or Pulse Pressure Analysis. Starting from a similar principle three main devices are now available on the market, with different algorithms and features: center dot PiCCO System (Pulsion Medical System, Munich, Germany) center dot LiDCO (TM) plus System (LidCO, Cambridge, UK) center dot Flotrac technology and Vigileo Monitor (Edwards Lifesciences, Irvine, CA, USA). The algorithm used by all these devices has been also implemented even with the analysis of the variation of stroke volume (SW) and of the pulse pressure (PPV). SW and PPV represent the variation of stroke volume and of the pulse pressure during the respiratory cycle. In sedated ventilated patients these indexes have proven to predict the response to a fluid challenge. A high variation (> 10-12%) identifies with good sensitivity and specificity responders and not responders.
引用
收藏
页码:7 / 9
页数:3
相关论文
共 50 条
[31]   Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output [J].
Vasdev, Sumit ;
Chauhan, Sandeep ;
Choudhury, Minati ;
Hote, Millind P. ;
Malik, Madhur ;
Kiran, Usha .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) :115-120
[32]   Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output [J].
Sumit Vasdev ;
Sandeep Chauhan ;
Minati Choudhury ;
Millind P. Hote ;
Madhur Malik ;
Usha Kiran .
Journal of Clinical Monitoring and Computing, 2012, 26 :115-120
[33]   Noninvasive and Minimally Invasive Cardiac Output Monitoring A Nursing Perspective [J].
Berndsen, Michelle .
DIMENSIONS OF CRITICAL CARE NURSING, 2022, 41 (03) :121-123
[34]   Role of cardiac output in mediating arterial blood pressure oscillations [J].
OLeary, DS ;
Woodbury, DJ .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 1996, 271 (03) :R641-R646
[35]   Cardiac output monitoring by pressure recording analytical method in cardiac surgery [J].
Giomarelli, P ;
Biagioli, B ;
Scolletta, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) :515-520
[36]   A Deep Learning Method for Intraoperative Age-agnostic and Disease-specific Cardiac Output Monitoring from Arterial Blood Pressure [J].
Yang, Hyun-Lim ;
Lee, Hyung-Chul ;
Jung, Chul-Woo ;
Kim, Min-Soo .
2020 IEEE 20TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE 2020), 2020, :662-666
[37]   Evaluation of the FloTrac Uncalibrated Continuous Cardiac Output System for Perioperative Hemodynamic Monitoring After Subarachnoid Hemorrhage [J].
Mutoh, Tatsushi ;
Ishikawa, Tatsuya ;
Nishino, Kyoko ;
Yasui, Nobuyuki .
JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2009, 21 (03) :218-225
[38]   Techniques for Non-Invasive Monitoring of Arterial Blood Pressure [J].
Meidert, Agnes S. ;
Saugel, Bernd .
FRONTIERS IN MEDICINE, 2018, 4
[39]   Cardiac output by Modelflow® method from intra-arterial and fingertip pulse pressure profiles [J].
Kenfack, MA ;
Lador, F ;
Licker, M ;
Moia, C ;
Tam, E ;
Capelli, C ;
Morel, D ;
Ferretti, G .
CLINICAL SCIENCE, 2004, 106 (04) :365-369
[40]   Pressure to perform: Is cardiac output estimation from arterial waveforms good enough for routine use? [J].
Gardner, Reed M. ;
Beale, Richard J. .