Mini invasive hemodynamic monitoring: from arterial pressure to cardiac output

被引:0
作者
Della Rocca, Giorgio [1 ]
Cecconi, Maurizio [1 ]
Costa, Maria Gabriella [1 ]
机构
[1] Univ Udine, Sch Med, Dept Anesthesia & Intens Care Med, I-33100 Udine, Italy
关键词
cardiac output; arterial pressure; stroke volume variation; pulse pressure variation;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To evaluate the Cardiac Output (CO) the standard invasive pulmonary artery catheter (PAC) is considered today the gold standard. The major criticism to the PAC is that its level of invasiveness is not supported by an improvement in patient's outcome. The interest to lesser and lesser invasive techniques is high. Therefore, the alternative techniques have been recently developed. Cardiac Output can be monitored continuously by different devices that analyze the arterial waveform to track changes in stroke volume (SV) and CO. The analysis of the arterial pressure wave to determine cardiac output is classified as Pulse Contour analysis or Pulse Pressure Analysis. Starting from a similar principle three main devices are now available on the market, with different algorithms and features: center dot PiCCO System (Pulsion Medical System, Munich, Germany) center dot LiDCO (TM) plus System (LidCO, Cambridge, UK) center dot Flotrac technology and Vigileo Monitor (Edwards Lifesciences, Irvine, CA, USA). The algorithm used by all these devices has been also implemented even with the analysis of the variation of stroke volume (SW) and of the pulse pressure (PPV). SW and PPV represent the variation of stroke volume and of the pulse pressure during the respiratory cycle. In sedated ventilated patients these indexes have proven to predict the response to a fluid challenge. A high variation (> 10-12%) identifies with good sensitivity and specificity responders and not responders.
引用
收藏
页码:7 / 9
页数:3
相关论文
共 50 条
  • [21] New aspects of minimally invasive cardiac output monitoring
    Hofer, Christoph K.
    Schmid, Ursina M.
    Zollinger, Andreas
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2012, 47 (02): : 102 - 108
  • [22] Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis
    Lu, Zhenwei
    Mukkamala, Ramakrishna
    JOURNAL OF APPLIED PHYSIOLOGY, 2006, 101 (02) : 598 - 608
  • [23] Arterial pressure based cardiac output in the septic patient
    C Slagt
    S van Bennekom
    J Beute
    M Hoeksema
    T Turk
    J Mulder
    R Perez
    Critical Care, 10 (Suppl 1):
  • [24] Hemodynamic profiles of arterial hypertension with ambulatory blood pressure monitoring
    Aristizabal-Ocampo, Dagnovar
    Alvarez-Montoya, Diego
    Madrid-Munoz, Camilo
    Fallon-Giraldo, Simon
    Gallo-Villegas, Jaime
    HYPERTENSION RESEARCH, 2023, 46 (06) : 1482 - 1492
  • [25] Invasive Hemodynamic Monitoring
    Magder, Sheldon
    CRITICAL CARE CLINICS, 2015, 31 (01) : 67 - +
  • [27] Monitoring: from cardiac output monitoring to echocardiography
    Jozwiak, Mathieu
    Monnet, Xavier
    Teboul, Jean-Louis
    CURRENT OPINION IN CRITICAL CARE, 2015, 21 (05) : 395 - 401
  • [28] Anesthetics management of a renal angiomyolipoma using pulse pressure variation and non-invasive cardiac output monitoring: A case report
    Jeon, Woo Jae
    Shin, Woo Jong
    Yoon, Young Joon
    Park, Chan Woo
    Shim, Jae Hang
    Cho, Sang Yun
    WORLD JOURNAL OF CLINICAL CASES, 2022, 10 (24) : 8656 - 8661
  • [29] Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery
    Hofhuizen, C. M.
    Lemson, J.
    Hemelaar, A. E. A.
    Settels, J. J.
    Schraa, O.
    Singh, S. K.
    van der Hoeven, J. G.
    Scheffer, G. J.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (04) : 493 - 500
  • [30] Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output
    Vasdev, Sumit
    Chauhan, Sandeep
    Choudhury, Minati
    Hote, Millind P.
    Malik, Madhur
    Kiran, Usha
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) : 115 - 120