CMS Pixel status

被引:3
|
作者
Gaz, Alessandro [1 ]
机构
[1] Univ Colorado, Boulder, CO 80309 USA
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2013年 / 731卷
基金
英国科学技术设施理事会;
关键词
CMS; Pixel; Silicon detector; Performance;
D O I
10.1016/j.nima.2013.04.001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The core of the CMS experiment is a three layers Pixel detector. Installed in 2008, the CMS Pixel system is essential for track seeding and reconstruction of secondary vertices. The Pixel detector was designed for a peak luminosity of 10(34) cm(-2) s(-1). In this contribution we summarize the operational experience of the first three years of collisions at the LHC. We present the measured performance evolution as the instantaneous luminosity delivered increased by several orders of magnitude, including dynamic data-losses, efficiency and resolution. The focus is on operational parameters, online calibrations and an overview of the challenges encountered to present. (C) 2013 CERN. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:13 / 17
页数:5
相关论文
共 50 条
  • [1] Status of the CMS pixel project
    Uplegger, Lorenzo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 596 (01): : 63 - 65
  • [2] Status of the CMS Pixel detector
    Kotlinski, D.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [3] The status of the CMS forward pixel detector
    Tan, Ping
    Particles and Nuclei, 2006, 842 : 1076 - 1078
  • [4] Status and Plan for The Upgrade of The CMS Pixel Detector
    Lu, Rong-Shyang
    NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2016, 273 : 1029 - 1033
  • [5] Status of the CMS Phase I pixel detector upgrade
    Spannagel, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 831 : 71 - 75
  • [6] Radiation hardness of CMS pixel barrel modules
    Rohe, T.
    Bean, A.
    Erdmann, W.
    Kastli, H-C
    Khalatyan, S.
    Meier, B.
    Radicci, V.
    Sibille, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 624 (02): : 414 - 418
  • [7] Performance of irradiated CMS forward pixel detector
    Taroni, S.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 585 - 589
  • [8] The CMS pixel luminosity telescope
    Kornmayer, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 304 - 306
  • [9] Overview and present status of the CMS Phase 1 pixel upgrade
    Lipinski, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 27 - 29
  • [10] Sensor development for the CMS pixel detector
    Bolla, G
    Bortoletto, D
    Horisberger, R
    Kaufmann, R
    Rohe, T
    Roy, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (1-2): : 89 - 99