Irish X-ray departments demonstrate varying levels of adherence to European guidelines on good radiographic technique

被引:18
作者
Brennan, PC [1 ]
Johnston, D [1 ]
机构
[1] UCD Sch Diagnost Imaging, Dublin 4, Ireland
关键词
D O I
10.1259/bjr.75.891.750243
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Commission of European Communities (CEC) publication "European Guidelines oil Quality Criteria for Diagnostic Radiographic Images" includes examples of good radiographic technique for a number of common X-ray examinations. If these guidelines are followed, compliance with dose and image quality criteria as specified in the CEC document should be demonstrated. Studies in England, Germany and Greece have shown that a number of X-ray departments are not using optimum techniques. The aim of this study is to demonstrate the level of adherence to CEC guidelines in Irish hospitals 3-4 years following publication of the above document. 16 hospitals were randomly chosen and the following details on technique and equipment were recorded for chest, abdomen, pelvis and lumbar spine examinations of standard sized patients: tube potential, focus-to-film distance, automatic exposure control (AEC), film-screen combination, X-ray tube filtration and secondary radiation grid. Varying levels of adherence to the guidelines were evident depending on the parameter being investigated, with no hospital demonstrating 100% compliance and no hospital demonstrating 100% non-compliance. For all parameters, with the exception of AEC use, the majority of hospitals exhibited non-adherence for at least one projection. The results suggest that if hospitals in Ireland observe the straightforward examples of good radiographic technique described in the CEC publication, significant reductions in collective dose can be achieved.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 18 条
[1]  
Brennan P. C., 1998, RADIOGRAPHY, V4, P251
[2]  
Commission of the European Communities, 1996, EUR GUID QUAL CRIT D
[3]   Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals [J].
Johnston, DA ;
Brennan, PC .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (868) :396-402
[4]   IMPLEMENTATION OF A PROGRAM FOR REDUCTION OF RADIOGRAPHIC DOSES AND RESULTS ACHIEVED THROUGH INCREASES IN TUBE POTENTIAL [J].
MARTIN, CJ ;
DARRAGH, CL ;
MCKENZIE, GA ;
BAYLISS, AP .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (783) :228-233
[5]  
MCNEIL EA, 1995, RADIAT PROT DOSIM, V57, P437
[6]   Dose reduction in a paediatric X-ray department following optimization of radiographic technique [J].
Mooney, R ;
Thomas, PS .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (848) :852-860
[7]  
MOORES BM, 1989, QUALITY CRITERIA DIA, P271
[9]  
*NRPB, 1992, PHYS SCI MED
[10]   Estimation of doses received by patients undergoing radiological examinations in Greece [J].
Papageorgiou, E ;
Vardalaki, E ;
Hourdakis, CJ ;
Dimitriou, P .
RADIATION PROTECTION DOSIMETRY, 2001, 93 (01) :31-41