Development of a flickermeter for grid-connected wind turbines using a DSP-based prototyping system

被引:11
作者
Gherasim, C [1 ]
Croes, T [1 ]
Van den Keybus, J [1 ]
Driesen, J [1 ]
Belmans, RJM [1 ]
机构
[1] Catholic Univ Louvain, B-3001 Heverlee, Belgium
关键词
accelerated testing; flickermeter; grid simulation; power quality; wind turbine;
D O I
10.1109/TIM.2006.870117
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The measurement of one of the power-quality problems (flicker), which may arise due to the presence of wind-turbine generators, is presented. This paper focuses on the design of a complete fully digital flickermeter relying on an in-house-developed measurement system, which features a data-acquisition system, using a C6711 DSP-based starter kit (DSK) and a field programmable gate array (FPGA). To study flicker produced during the wind turbine's continuous operation, special attention is given to the simulation of the voltage fluctuations on a fictitious grid.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 10 条
[1]   VOLTAGE FLICKER MEASUREMENT AND ANALYSIS SYSTEM [J].
BISHOP, MT ;
DO, AV ;
MENDIS, SR .
IEEE COMPUTER APPLICATIONS IN POWER, 1994, 7 (02) :34-38
[2]   Digital algorithms for measurement of voltage flicker [J].
Chen, MT .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1997, 144 (02) :175-180
[3]  
Fallon C. M., 1996, P TRANSM DISTR C SEP, P31
[4]   DSP implementation of power measurements according to the IEEE trial-use standard 1459 [J].
Gherasim, C ;
Van den Keybus, J ;
Driesen, J ;
Belmans, R .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2004, 53 (04) :1086-1092
[5]   MEASUREMENT AND PREDICTION OF VOLTAGE FLICKER MAGNITUDE AND FREQUENCY [J].
GIRGIS, AA ;
STEPHENS, JW ;
MAKRAM, EB .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) :1600-1605
[6]  
*IEC, 2003, 6100415 IEC
[7]  
IEC, 2001, 6140021 IEC
[8]  
*JOING GROUP POW Q, CCU2CIGREC405CIRED
[9]  
SORENSEN P, 2001, TASK 2 POWER QUALITY
[10]  
VANDENKEYBUS J, 2003, THESIS KATHOLIEKE U