Angle-independent strain mapping in myocardial elastography - 2D strain tensor characterization and principal component imaging

被引:0
作者
Fung-Kee-Fung, SD [1 ]
Lee, WN [1 ]
Ingrassia, CM [1 ]
Costa, KD [1 ]
Konofagou, EE [1 ]
机构
[1] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
来源
2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 | 2005年
关键词
angle-independent; eigenvalue; elastography; finite-element analysis; myocardial; principal strain;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A current limitation of the implementation of myocardial elastography in a clinical setting is the difficulty of interpreting the one-dimensional strain maps due to varying strain values in the wall of the left ventricle (LV). In this paper, we demonstrate a robust angle-independent method for 2D myocardial elastography on simulated 2D ultrasonic images of a 3D finite-element analysis (FEA) model of the LV. Two FEA, a control and a regionally ischemic, canine left-ventricular models, were used and model states were obtained in increments and accumulated from end-diastole (ED) to end-systole (ES). Two-dimensional (21)) displacement in the myocardium. was estimated between ED to ES. These estimates were good approximations of the FEA solution (rms errors of 0.18 min for lateral displacement and 0.12 min for axial displacement). The 2D symmetric strain tensor was calculated from the displacements and angle-independent principal strains were obtained using eigenvalue decomposition of the strain tensor. Principal strains in the myocardium have been shown to approximate normal strains with respect to an anatomical coordinate system [5]. To test this angle-independence, displacements were obtained from two different orthogonally placed transducer locations. Principal strains were estimated from both locations and showed good correlation to the FEA solution. Rms errors between the FEA model and 2D elastography (2DE) estimation of principal strains from both transducer locations were 1.7% and 2.4% strain, respectively. Visualizing the transmural strain using principal strains greatly simplified their interpretation. Moreover, abnormal deformation of the ischemic region, which was difficult to observe with axial and lateral strains, was clearly visible in the principal strain images. In summary, the feasibility of 2D elastography estimation of myocardial displacement and strain was shown. In this paper, we propose the use of principal strains as a more useful tool in the visualization of abnormal wall motion and the detection of ischemia and other related heart diseases.
引用
收藏
页码:516 / 519
页数:4
相关论文
共 11 条
  • [1] A three-dimensional finite element method for large elastic deformations of ventricular myocardium .2. Prolate spheroidal coordinates
    Costa, KD
    Hunter, PJ
    Wayne, JS
    Waldman, LK
    Guccione, JM
    McCulloch, AD
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (04): : 464 - 472
  • [2] Two-dimensional ultrasonic strain rate measurement of the human heart in vivo
    D'hooge, J
    Konofagou, E
    Jamal, F
    Heimdal, A
    Barrios, L
    Bijnens, B
    Thoen, J
    Van de Werf, F
    Sutherland, G
    Suetens, P
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (02) : 281 - 286
  • [3] NONHOMOGENEOUS ANALYSIS OF EPICARDIAL STRAIN DISTRIBUTIONS DURING ACUTE MYOCARDIAL-ISCHEMIA IN THE DOG
    HASHIMA, AR
    YOUNG, AA
    MCCULLOCH, AD
    WALDMAN, LK
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (01) : 19 - 35
  • [4] A least-squares strain estimator for elastography
    Kallel, F
    Ophir, J
    [J]. ULTRASONIC IMAGING, 1997, 19 (03) : 195 - 208
  • [5] A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues
    Konofagou, E
    Ophir, J
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (08) : 1183 - 1199
  • [6] Myocardial elastography - A feasibility study in vivo
    Konofagou, EE
    D'Hooge, J
    Ophir, J
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (04) : 475 - 482
  • [7] Theoretical bounds on the estimation of transverse displacement, transverse strain and Poisson's ratio in elastography
    Konofagou, EE
    Varghese, T
    Ophir, J
    [J]. ULTRASONIC IMAGING, 2000, 22 (03) : 153 - 177
  • [8] Structural basis of regional dysfunction in acutely ischemic myocardium
    Mazhari, R
    Omens, JH
    Covell, JW
    McCulloch, AD
    [J]. CARDIOVASCULAR RESEARCH, 2000, 47 (02) : 284 - 293
  • [9] MEUNIER J, 1987, SPIE PATTERN RECOGNI, V768, P193
  • [10] A theoretical framework for performance characterization of elastography: The strain filter
    Varghese, T
    Ophir, J
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (01) : 164 - 172