Comparison of Advanced Control Techniques for Grid Side Converter of Doubly-Fed Induction Generator Back-to-Back Converters to Improve Power Quality Performance During Unbalanced Voltage Dips

被引:33
作者
Baggu, Murali M. [1 ]
Chowdhury, Badrul H. [2 ]
Kimball, Jonathan W. [3 ]
机构
[1] GE Global Res Ctr, Schenectady, NY 12309 USA
[2] Missouri Univ Sci & Technol, Rolla, MO 65409 USA
[3] Univ Illinois, Champaign, IL 61801 USA
基金
美国国家科学基金会;
关键词
Back-to-back pulsewidth modulation (PWM) converters; current control; direct power control (DPC); doubly-fed induction generator (DFIG); sequence domain control (SDC); voltage dip; voltage source converters (VSCs); PWM CONVERTER; WIND TURBINE; DFIG;
D O I
10.1109/JESTPE.2014.2359205
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A doubly-fed induction generator grid side converter is studied under voltage disturbances. During voltage dips, conventional current control techniques involving the decoupling of d-q axis in the synchronous reference frame (SRF) exhibits oscillations in the stiff dc link voltage, as well as in the active and reactive power outputs of the voltage source converter (VSC). To mitigate the oscillations, an advanced control technique called the sequence domain control (SDC) is evaluated. This approach implements individual controllers in the positive and negative sequence domains and demonstrates stabilization of the dc link voltage to a greater extent during a disturbance, but is more sluggish than the conventional control. An innovative control technique called direct power control (DPC) is also investigated. This control achieves active and reactive power stability with simple active and reactive power control variables replacing the traditional current control loops. The DPC technique is verified using a prototype in the laboratory. A modified DPC algorithm combining the benefits of DPC and SDC to eliminate the current harmonics created by DPC during system disturbances is introduced. The benefits of the proposed controllers are compared using a simulation of voltage dip on a VSC based on the IEC-61400-21 standard.
引用
收藏
页码:516 / 524
页数:9
相关论文
共 21 条
[1]  
[Anonymous], 60 ANN C PROT REL EN
[2]  
[Anonymous], 2008, IEC 61400-21
[3]  
Baggu M. M., 2009, THESIS MISSOURI U SC
[4]  
Baggu M. M., 2007, P PES GEN M TAMP FL, P1
[5]   Direct Power Control of Doubly-Fed Generator Based Wind Turbine Converters to Improve Low Voltage Ride-Through during System Imbalance [J].
Baggu, Murali M. ;
Watson, Luke D. ;
Kimball, Jonathan W. ;
Chowdhury, Badrul H. .
2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, :2121-2125
[6]   Extended Direct Power Control of a Three-Level Neutral Point Clamped Voltage Source Inverter with Unbalanced Voltages [J].
Eloy-Garcia, Joaquin ;
Arnaltes, Santiago ;
Rodriguez-Amenedo, Jose Luis .
2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, :3396-3400
[7]  
Enjeti P. N., 1993, IEEE Transactions on Power Electronics, V8, P493, DOI 10.1109/63.261020
[8]   Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions [J].
Hu, Jia-bing ;
He, Yi-kang ;
Xu, Lie .
JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2008, 9 (12) :1731-1740
[9]  
Kim HS, 1998, IEEE POWER ELECTRON, P503, DOI 10.1109/PESC.1998.701945
[10]   An Improved Control Method for a DFIG in a Wind Turbine under an Unbalanced Grid Voltage Condition [J].
Lee, Sol-Bin ;
Lee, Kyo-Beum ;
Lee, Dong-Choon ;
Kim, Jang-Mok .
JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2010, 5 (04) :614-622