Determination of Glucose and Cholesterol Using a Novel Optimized Luminol- CuO Nanoparticles-H2O2 Chemiluminescence Method by Box-Behnken Design

被引:13
作者
Chaichi, Mohammad Javad [1 ]
Ehsani, Mahjoobeh [1 ]
机构
[1] Univ Mazandaran, Fac Chem, Babol Sar, Iran
关键词
Luminol chemiluminescence; Box-Behnken design; Glucose; Cholesterol; CuO nanoparticles; GOLD NANOPARTICLES; INJECTION ANALYSIS; HYDROGEN-PEROXIDE; NAFION FILM; BIOSENSOR; SENSOR; LUMINESCENCE; CHEMISTRY; MECHANISM; ELECTRODE;
D O I
10.1007/s10895-015-1566-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a simple, rapid and sensitive luminol-CuO nanoparticles-H2O2 chemiluminescence (CL) method has been proposed for determination of glucose and cholesterol in plasma. Response surface methodology (RSM) based on Box-Behnken design (BBD) was used to optimize the most important operating variables (solution pH effect and the CL reagents concentration) of luminol CL system. In optimum conditions, it was found that CuO nanoparticles (NPs) could enhance the CL intensity and the method sensitivity towards evaluation of trace amount of glucose and cholesterol. Under the optimal conditions, there is a good linear relationship between the luminol-CuO NPs - H2O2 relative CL intensity and the concentration over the range of 1.2 x 10(-6)-1.0 x 10(-3) M (R (2) = 0.9991) for glucose and 2.5 x 10(-5)-CuO NPs7.17 x 10(-3) M (R (2) = 0.9968) for cholesterol and with a 3 sigma detection limit of 7.1 x 10(-7) and 6.4 x 10(-6) M, respectively. The relative standard deviations (RSD) < 3.3% were obtained.
引用
收藏
页码:861 / 870
页数:10
相关论文
共 54 条
[1]   Recent developments and applications of chemiluminescence sensors [J].
Aboul-Enein, HY ;
Stefan, RI ;
van Staden, JF ;
Zhang, XR ;
Garcia-Campana, AM ;
Baeyens, WRG .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2000, 30 (04) :271-289
[2]  
Adinarayana K, 2002, J PHARM PHARM SCI, V5, P281
[3]  
Albreacht HO, 1928, Z PHYS CHEM-STOCH VE, V136, P321
[4]  
Alexander LF, 1954, XRAY DIFRACTION PROC
[5]   Advances in analytical methods to study cholesterol metabolism: the determination of serum noncholesterol sterols [J].
Andrade, Isabel ;
Santos, Lelita ;
Ramos, Fernando .
BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (10) :1234-1242
[6]   Effect of eluent composition and pH and chemiluminescent reagent pH on ion chromatographic selectivity and luminol-based chemiluminescence detection of Co2+, Mn2+ and Fe2+ at trace levels [J].
Badocco, Denis ;
Pastore, Paolo ;
Favaro, Gabriella ;
Macca, Carlo .
TALANTA, 2007, 72 (01) :249-255
[7]   An electrochemical multienzymatic biosensor for determination of cholesterol [J].
Bongiovanni, C ;
Ferri, T ;
Poscia, A ;
Varalli, M ;
Santucci, R ;
Desideri, A .
BIOELECTROCHEMISTRY, 2001, 54 (01) :17-22
[8]  
Box GEP., 1960, Technometrics, V2, P455, DOI [10.1080/00401706.1960.10489912, DOI 10.1080/00401706.1960.10489912, 10.2307/1266454]
[9]  
BRETT AMCFO, 1992, BIOELECTROCH BIOENER, V28, P105
[10]   Macroporous ordered silica foam for glucose oxidase immobilisation and direct electrochemical biosensing [J].
Cao, Xiaodong ;
Sun, Yuxue ;
Ye, Yongkang ;
Li, Ying ;
Ge, Xiaoguang .
ANALYTICAL METHODS, 2014, 6 (05) :1448-1454