Simultaneous intracranial EEG-fMRI in humans: Protocol considerations and data quality

被引:51
作者
Carmichael, D. W. [1 ,2 ]
Vulliemoz, S. [2 ,3 ,4 ]
Rodionov, R. [2 ]
Thornton, J. S. [5 ]
McEvoy, A. W. [6 ]
Lemieux, L. [2 ]
机构
[1] UCL Inst Child Hlth, Imaging & Biophys Unit, London WC1N 1EH, England
[2] UCL Inst Neurol, Dept Clin & Expt Epilepsy, London WC1E 6BT, England
[3] Univ Hosp, Dept Neurol, Epilepsy Unit, CH-1211 Geneva 14, Switzerland
[4] Univ Geneva, CH-1211 Geneva 14, Switzerland
[5] Natl Hosp Neurol & Neurosurg, Lysholm Dept Neuroradiol, London WC1N 3BG, England
[6] Natl Hosp Neurol & Neurosurg, Victor Horsley Dept Neurosurg, London WC1N 3BG, England
基金
瑞士国家科学基金会; 英国医学研究理事会;
关键词
EEG-fMRI; Intracranial EEG; Functional MRI; fMRI; Data quality; icEEG-fMRI; Electrophysiology; BOLD; Simultaneous EEG and fMRI; BOLD SENSITIVITY LOSSES; FUNCTIONAL MRI; ARTIFACT; SAFETY;
D O I
10.1016/j.neuroimage.2012.05.056
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We have recently performed simultaneous intracranial EEG and fMRI recordings (icEEG-fMRI) in patients with epilepsy. In this technical note, we examine limited thermometric data for potential electrode heating during our protocol and found that heating was <= 0.1 degrees C in-vitro at least 10 fold less than in-vivo limits. We quantify EEG quality, which can be degraded by MRI scanner-induced artefacts, and fMRI image (gradient echo echo-planar imaging: GE-EPI) signal quality around the electrodes, which can be degraded by electrode interactions with B1 (radiofrequency) and B0 (static) magnetic fields. We recorded EEG outside and within the MRI scanner with and without scanning. EEG quality was largely preserved during scanning and in particular heartbeat-related artefacts were small compared to epileptic events. To assess the GE-EPI signal reduction around the electrodes, we compared image signal intensity along paths into the brain normal to its surface originating from the individual platinum-iridium electrode contacts. GE-EPI images were obtained at 1.5 T with an echo time (TE) of 40 ms and repetition time (TR) of 3000 ms and a slice thickness of 2.5 mm. We found that GE-EPI signal intensity reduction was confined to a 10 mm radius and that it was reduced on average by less than 50% at 5 mm from the electrode contacts. The GE-EPI image signal reduction also varied with electrode orientation relative to the MRI scanner axes; in particular, cortical grid contacts with a normal along the scanner's main magnetic field (Be) axis have higher artefact levels relative to those with a normal perpendicular to the z-axis. This suggests that the artefacts were predominantly susceptibility-related rather than due to B1 interactions. This information can be used to guide interpretation of results of icEEG-fMRI experiments proximal to the electrodes, and to optimise artefact reduction strategies. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 17 条
  • [1] Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction
    Allen, PJ
    Polizzi, G
    Krakow, K
    Fish, DR
    Lemieux, L
    [J]. NEUROIMAGE, 1998, 8 (03) : 229 - 239
  • [2] A method for removing imaging artifact from continuous EEG recorded during functional MRI
    Allen, PJ
    Josephs, O
    Turner, R
    [J]. NEUROIMAGE, 2000, 12 (02) : 230 - 239
  • [3] Artifacts in magnetic resonance imaging from metals
    Bennett, LH
    Wang, PS
    Donahue, MJ
    [J]. JOURNAL OF APPLIED PHYSICS, 1996, 79 (08) : 4712 - 4714
  • [4] Carmichael D.W., 2008, P INT M ISMRM TOR, P1061
  • [5] Carmichael D, 2010, EEG-FMRI: PHYSIOLOGICAL BASIS, TECHNIQUE AND APPLICATIONS, P173, DOI 10.1007/978-3-540-87919-0_10
  • [6] Functional MRI with active, fully implanted, deep brain stimulation systems: Safety and experimental confounds
    Carmichael, David W.
    Pinto, Serge
    Limousin-Dowsey, Patricia
    Thobois, Stephane
    Allen, Philip J.
    Lemieux, Louis
    Yousry, Tarek
    Thornton, John S.
    [J]. NEUROIMAGE, 2007, 37 (02) : 508 - 517
  • [7] Feasibility of simultaneous intracranial EEG-fMRI in humans: A safety study
    Carmichael, David W.
    Thornton, John S.
    Rodionov, Roman
    Thornton, Rachel
    McEvoy, Andrew W.
    Ordidge, Roger J.
    Allen, Philip J.
    Lemieux, Louis
    [J]. NEUROIMAGE, 2010, 49 (01) : 379 - 390
  • [8] Safety of Localizing Epilepsy Monitoring Intracranial Electroencephalograph Electrodes Using MRI: Radiofrequency-Induced Heating
    Carmichael, David W.
    Thornton, John S.
    Rodionov, Roman
    Thornton, Rachel
    McEvoy, Andrew
    Allen, Philip J.
    Lemieux, Louis
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (05) : 1233 - 1244
  • [9] Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI Imaging
    Deichmann, R
    Josephs, O
    Hutton, C
    Corfield, DR
    Turner, R
    [J]. NEUROIMAGE, 2002, 15 (01) : 120 - 135
  • [10] Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia
    Dewhirst, MW
    Viglianti, BL
    Lora-Michiels, M
    Hanson, M
    Hoopes, PJ
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2003, 19 (03) : 267 - 294