Simultaneous intracranial EEG-fMRI in humans: Protocol considerations and data quality

被引:51
|
作者
Carmichael, D. W. [1 ,2 ]
Vulliemoz, S. [2 ,3 ,4 ]
Rodionov, R. [2 ]
Thornton, J. S. [5 ]
McEvoy, A. W. [6 ]
Lemieux, L. [2 ]
机构
[1] UCL Inst Child Hlth, Imaging & Biophys Unit, London WC1N 1EH, England
[2] UCL Inst Neurol, Dept Clin & Expt Epilepsy, London WC1E 6BT, England
[3] Univ Hosp, Dept Neurol, Epilepsy Unit, CH-1211 Geneva 14, Switzerland
[4] Univ Geneva, CH-1211 Geneva 14, Switzerland
[5] Natl Hosp Neurol & Neurosurg, Lysholm Dept Neuroradiol, London WC1N 3BG, England
[6] Natl Hosp Neurol & Neurosurg, Victor Horsley Dept Neurosurg, London WC1N 3BG, England
基金
瑞士国家科学基金会; 英国医学研究理事会;
关键词
EEG-fMRI; Intracranial EEG; Functional MRI; fMRI; Data quality; icEEG-fMRI; Electrophysiology; BOLD; Simultaneous EEG and fMRI; BOLD SENSITIVITY LOSSES; FUNCTIONAL MRI; ARTIFACT; SAFETY;
D O I
10.1016/j.neuroimage.2012.05.056
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We have recently performed simultaneous intracranial EEG and fMRI recordings (icEEG-fMRI) in patients with epilepsy. In this technical note, we examine limited thermometric data for potential electrode heating during our protocol and found that heating was <= 0.1 degrees C in-vitro at least 10 fold less than in-vivo limits. We quantify EEG quality, which can be degraded by MRI scanner-induced artefacts, and fMRI image (gradient echo echo-planar imaging: GE-EPI) signal quality around the electrodes, which can be degraded by electrode interactions with B1 (radiofrequency) and B0 (static) magnetic fields. We recorded EEG outside and within the MRI scanner with and without scanning. EEG quality was largely preserved during scanning and in particular heartbeat-related artefacts were small compared to epileptic events. To assess the GE-EPI signal reduction around the electrodes, we compared image signal intensity along paths into the brain normal to its surface originating from the individual platinum-iridium electrode contacts. GE-EPI images were obtained at 1.5 T with an echo time (TE) of 40 ms and repetition time (TR) of 3000 ms and a slice thickness of 2.5 mm. We found that GE-EPI signal intensity reduction was confined to a 10 mm radius and that it was reduced on average by less than 50% at 5 mm from the electrode contacts. The GE-EPI image signal reduction also varied with electrode orientation relative to the MRI scanner axes; in particular, cortical grid contacts with a normal along the scanner's main magnetic field (Be) axis have higher artefact levels relative to those with a normal perpendicular to the z-axis. This suggests that the artefacts were predominantly susceptibility-related rather than due to B1 interactions. This information can be used to guide interpretation of results of icEEG-fMRI experiments proximal to the electrodes, and to optimise artefact reduction strategies. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 50 条
  • [1] Data quality in fMRI and simultaneous EEG-fMRI
    Ihalainen, Toni
    Kuusela, Linda
    Turunen, Sampsa
    Heikkinen, Sami
    Savolainen, Sauli
    Sipila, Outi
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (01) : 23 - 31
  • [2] Feasibility of simultaneous intracranial EEG-fMRI in humans: A safety study
    Carmichael, David W.
    Thornton, John S.
    Rodionov, Roman
    Thornton, Rachel
    McEvoy, Andrew W.
    Ordidge, Roger J.
    Allen, Philip J.
    Lemieux, Louis
    NEUROIMAGE, 2010, 49 (01) : 379 - 390
  • [3] Quality of EEG in simultaneous EEG-fMRI for epilepsy
    Bénar, CG
    Aghakhani, Y
    Wang, YH
    Izenberg, A
    Al-Asmi, A
    Dubeau, F
    Gotman, J
    CLINICAL NEUROPHYSIOLOGY, 2003, 114 (03) : 569 - 580
  • [4] SIMULTANEOUS INTRACRANIAL EEG-fMRI IN PATIENTS WITH EPILEPSY
    Carmichael, D.
    Vulliemoz, S.
    Rosenkranz, K.
    Diehl, B.
    Walker, M.
    Rodionov, R.
    McEvoy, A.
    Lemieux, L.
    EPILEPSIA, 2010, 51 : 17 - 18
  • [5] Simultaneous EEG-fMRI
    Ritter, Petra
    Villringer, Arno
    NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 2006, 30 (06): : 823 - 838
  • [6] Intracranial EEG-fMRI analysis of focal epileptiform discharges in humans
    Cunningham, Cameron B. J.
    Goodyear, Bradley G.
    Badawy, Radwa
    Zaamout, Fateh
    Pittman, Daniel J.
    Beers, Craig A.
    Federico, Paolo
    EPILEPSIA, 2012, 53 (09) : 1636 - 1648
  • [7] Mapping Epileptic Networks Using Simultaneous Intracranial EEG-fMRI
    Chaudhary, Umair J.
    Centeno, Maria
    Carmichael, David W.
    Diehl, Beate
    Walker, Matthew C.
    Duncan, John S.
    Lemieux, Louis
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [8] Feasibility of an intracranial EEG-fMRI protocol at 3 T: Risk assessment and image quality
    Boucousis, Shannon M.
    Beers, Craig A.
    Cunningham, Cameron J. B.
    Gaxiola-Valdez, Ismael
    Pittman, Daniel J.
    Goodyear, Bradley G.
    Federico, Paolo
    NEUROIMAGE, 2012, 63 (03) : 1237 - 1248
  • [9] HIPPOCAMPAL ACTIVATION IN SIMULTANEOUS INTRACRANIAL EEG-fMRI: A CASE REPORT
    Pugnaghi, M.
    Chaudhary, U. J.
    Rodionov, R.
    Diehl, B.
    Mc Evoy, A.
    Walker, M.
    Duncan, J. S.
    Carmichael, D. W.
    Lemieux, L.
    EPILEPSIA, 2011, 52 : 179 - 180
  • [10] Ordinal patterns in epileptic brains: Analysis of intracranial EEG and simultaneous EEG-fMRI
    Rummel, C.
    Abela, E.
    Hauf, M.
    Wiest, R.
    Schindler, K.
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2013, 222 (02): : 569 - 585