Hybrid biosensor for simultaneous electrochemical and thermometric detection

被引:6
|
作者
Xie, B
Tang, XJ
Wollenberger, U
Johansson, G
Gorton, L
Scheller, F
Danielsson, B
机构
[1] LUND UNIV,DEPT ANALYT CHEM,S-22100 LUND,SWEDEN
[2] UNIV POTSDAM,DEPT ANALYT BIOCHEM,MAX DELBRUCK CTR,D-13122 BERLIN,GERMANY
关键词
hybrid biosensor; electrochemical; thermal; catechol; tyrosinase;
D O I
10.1080/00032719708001729
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simultaneous detection of multiple signals for common biochemical/electrochemical reactions is a challenging area of research for comparative studies. Based on our previous work with electrochemically assisted thermal biosensors, a hybrid biosensor has been developed for the simultaneous monitoring of the electrochemically generated current and the thermal signal produced in association with enzymatic catalysis. The sensor combined the two measurement principles of electrochemical regeneration of substrate and flow injection biocalorimetry. The enzyme column was constructed of a platinum foil in electrical contact with a poly (pyrrole)-coated reticulated vitreous carbon (RVC) matrix onto which tyrosinase was immobilized. The column functioned as enzyme reactor, working electrode and thermally sensitive element together with the thermistors. Catechol was oxidized by tyrosinase to form 1,2-benzoquinone which was subsequently regenerated electrochemically on the electrode surface. The primary heat production developed by the enzyme reaction could be measured calorimetrically. At the same time, the electrochemical reduction of 1,2-benzoquinone generated a current that was detected by the working electrode (enzyme column). Preliminary results showed good correlation of the two signals at both high and low oxygen concentrations in the buffer. A linear range between 12.5 and 250 mu M catechol was obtained for the enzyme reaction. The sensitivity of the thermal measurement system was significantly enhanced by the recycling of catechol. The hybrid sensor provides a useful tool for comparative studies.
引用
收藏
页码:2141 / 2158
页数:18
相关论文
共 50 条
  • [1] Electrical, electrochemical, and thermometric sensors for the detection of explosives
    Buryakov, I. A.
    Buryakov, T. I.
    Matsayev, V. T.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (03) : 234 - 242
  • [2] Electrical, electrochemical, and thermometric sensors for the detection of explosives
    I. A. Buryakov
    T. I. Buryakov
    V. T. Matsayev
    Journal of Analytical Chemistry, 2016, 71 : 234 - 242
  • [3] Fabrication of an Electrochemical Biosensor Array for Simultaneous Detection of L-Glutamate and Acetylcholine
    Deng, Yan
    Wang, Wei
    Ma, Chao
    Li, Zhiyang
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2013, 9 (08) : 1378 - 1382
  • [4] Pretreatment-free detection of diazepam in beverages based on a thermometric biosensor
    Xu, Ning
    Bai, Jialei
    Peng, Yuan
    Qie, Zhiwei
    Liu, Zengshan
    Tang, Hongzhi
    Liu, Chao
    Gao, Zhixian
    Ning, Baoan
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 504 - 512
  • [5] Electrochemical Biosensor for Detection of Bioagents
    Svabenska, Eva
    Kovar, David
    Krajicek, Vit
    Pribyl, Jan
    Skladal, Petr
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (12): : 5968 - 5979
  • [6] Design and development of electrochemical biosensor for the simultaneous detection of melamine and urea in adulterated milk samples
    Ezhilan, Madeswari
    Gumpu, Manju Bhargavi
    Ramachandra, Bhat Lakshmishri
    Nesakumar, Noel
    Babu, K. Jayanth
    Krishnan, Uma Maheswari
    Rayappan, John Bosco Balaguru
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 1283 - 1292
  • [7] Integrated biosensor for simultaneous detection by surface plasmon resonance and Faradaic electrochemical impedance spectroscopy
    Hong, Brandon
    Sun, Alexander
    Pang, Lin
    Venkatesh, A. G.
    Hall, Drew
    Fainman, Yeshaiahu
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,
  • [8] Flexible Nanostructured NiS-Based Electrochemical Biosensor for Simultaneous Detection of DNA Nucleobases
    Gaikwad, Prajakta N.
    Desai, Trishala R.
    Ghosh, Souradyuti
    Gurnani, Chitra
    ACS OMEGA, 2024,
  • [9] Simultaneous detection of sepsis host response biomarkers in whole blood using electrochemical biosensor
    Tanak, Ambalika S.
    Sardesai, Abha
    Muthukumar, Sriram
    Prasad, Shalini
    BIOENGINEERING & TRANSLATIONAL MEDICINE, 2022, 7 (03)
  • [10] Simultaneous Detection of Purine Bases on Cu2O Nanoparticles Based Electrochemical Biosensor
    Chomoucka, Jana
    Prasek, Jan
    Businova, Petra
    Drbohlavova, Jana
    Pekarek, Jan
    Hrdy, Radim
    Hubalek, Jaromir
    Trnkova, Libuse
    2012 IEEE SENSORS PROCEEDINGS, 2012, : 1208 - 1211