Application of synchrotron x-ray microtomography to investigate ductile fracture in Al alloys

被引:33
作者
Qian, L [1 ]
Toda, H
Uesugi, K
Kobayashi, T
Ohgaki, T
Kobayashi, M
机构
[1] Toyohashi Univ Technol, Dept Prod Syst, Toyohashi, Aichi 4418580, Japan
[2] Japan Synchrotron Radiat Res Inst, Sayo, Hyogo 6795198, Japan
[3] Toyohashi Univ Technol, Dept Prod Syst, Toyohashi, Aichi 4418580, Japan
基金
日本学术振兴会;
关键词
D O I
10.1063/1.2142081
中图分类号
O59 [应用物理学];
学科分类号
摘要
The in situ high-resolution synchrotron x-ray computed microtomography has been applied to visualize and quantify the ductile fracture process of a notched Al alloy specimen. The three-dimensional (3D) investigation reveals that voids are nucleated, grow and coalesce more easily near the notch front and in the central region of the sample. These voids are mainly associated with Si particles in the eutectic (EU) phase. The 3D packing architecture of particles in the EU region, and the 3D morphology of alpha phase are also visualized. The feasibility of this technique highlights the potential of its application in the field of micromechanics-based fracture. (c) 2005 American Institute of Physics.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 22 条
  • [11] Three dimensional morphology of cementite precipitates
    Kral, MV
    Spanos, G
    [J]. SCRIPTA MATERIALIA, 1997, 36 (08) : 875 - 882
  • [12] Microstructural characterization of electron beam-physical vapor deposition thermal barrier coatings through high-resolution computed microtomography
    Kulkarni, A
    Herman, H
    DeCarlo, F
    Subramanian, R
    [J]. METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2004, 35A (07): : 1945 - 1952
  • [13] Fracture behaviour and fracture toughness of ductile closed-cell metallic foams
    Motz, C
    Pippan, R
    [J]. ACTA MATERIALIA, 2002, 50 (08) : 2013 - 2033
  • [14] HIGH-ENERGY HIGH-RESOLUTION MONOCHROMATIC X-RAY COMPUTED-TOMOGRAPHY USING THE PHOTON FACTORY VERTICAL WIGGLER BEAMLINE
    NAGATA, Y
    YAMAJI, H
    HAYASHI, K
    KAWASHIMA, K
    HYODO, K
    KAWATA, H
    ANDO, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) : 615 - 618
  • [15] Quantitative assessment of liquid Ga penetration into an aluminium alloy by high-resolution X-ray tomography
    Ohgaki, T
    Toda, H
    Sinclair, I
    Buffière, JY
    Ludwig, W
    Kobayashi, T
    Niinomi, M
    Akahori, T
    [J]. MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2005, 406 (1-2): : 261 - 267
  • [16] OHGAKI T, UNPUB PHILOS MAG
  • [17] In-situ observations of fracture processes in 0.6 μm and 9.5 μm SiCP/6061Al composites
    Qian, LH
    Toda, H
    Morita, S
    Kobayashi, T
    Wang, ZG
    [J]. MATERIALS TRANSACTIONS, 2005, 46 (01) : 34 - 41
  • [18] X-ray computed microtomography of internal damage in fiber reinforced polymer matrix composites
    Schilling, PJ
    Karedla, BPR
    Tatiparthi, AK
    Verges, MA
    Herrington, PD
    [J]. COMPOSITES SCIENCE AND TECHNOLOGY, 2005, 65 (14) : 2071 - 2078
  • [19] X-ray microtomography of materials
    Stock, SR
    [J]. INTERNATIONAL MATERIALS REVIEWS, 1999, 44 (04) : 141 - 164
  • [20] A 3D measurement procedure for internal local crack driving forces via synchrotron X-ray microtomography
    Toda, H
    Sinclair, I
    Buffière, JY
    Maire, E
    Khor, KH
    Gregson, P
    Kobayashi, T
    [J]. ACTA MATERIALIA, 2004, 52 (05) : 1305 - 1317