Evaluation of PET texture features with heterogeneous phantoms: complementarity and effect of motion and segmentation method

被引:33
作者
Carles, M. [1 ,2 ]
Torres-Espallardo, I. [1 ]
Alberich-Bayarri, A. [1 ]
Olivas, C. [1 ]
Bello, P. [1 ]
Nestle, U. [2 ]
Marti-Bonmati, L. [1 ]
机构
[1] Hosp Univ & Politecn La Fe, Valencia 46026, Spain
[2] Univ Hosp Freiburg, D-79106 Freiburg, Germany
关键词
heterogeneous phantoms; retrospectively gated PET/CT; texture features; effect of respiratory motion; CELL LUNG-CANCER; F-18-FDG PET; FDG-PET; RESPIRATORY MOTION; GATED PET; IMPACT; IMAGES; RADIOMICS; VARIABILITY; DELINEATION;
D O I
10.1088/1361-6560/62/2/652
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A major source of error in quantitative PET/CT scans of lung cancer tumors is respiratory motion. Regarding the variability of PET texture features (TF), the impact of respiratory motion has not been properly studied with experimental phantoms. The primary aim of this work was to evaluate the current use of PET texture analysis for heterogeneity characterization in lesions affected by respiratory motion. Twenty-eight heterogeneous lesions were simulated by a mixture of alginate and 18F-fluoro-2-deoxy-D-glucose (FDG). Sixteen respiratory patterns were applied. Firstly, the TF response for different heterogeneous phantoms and its robustness with respect to the segmentation method were calculated. Secondly, the variability for TF derived from PET image with (gated, G-) and without (ungated, U-) motion compensation was analyzed. Finally, TF complementarity was assessed. In the comparison of TF derived from the ideal contour with respect to TF derived from 40%-threshold and adaptive-threshold PET contours, 7/8 TF showed strong linear correlation (LC) (p < 0.001, r > 0.75), despite a significant volume underestimation. Independence of lesion movement (LC in 100% of the combined pairs of movements, p < 0.05) was obtained for 1/8 TF with U-image (width of the volume-activity histogram, WH) and 4/8 TF with G-image (WH and energy (ENG), local-homogeneity (LH) and entropy (ENT), derived from the co-ocurrence matrix). Their variability in terms of the coefficient of variance (CV) resulted in CV (WH) = 0.18 on the U-image and CV(WH) = 0.24, CV(ENG) = 0.15, CV(LH) = 0.07 and CV(ENT) = 0.06 on the G-image. Apart from WH (r > 0.9, p < 0.001), not one of these TF has shown LC with C-max. Complementarity was observed for the TF pairs: ENG-LH, CONT (contrast)-ENT and LHENT. In conclusion, the effect of respiratory motion should be taken into account when the heterogeneity of lung cancer is quantified on PET/CT images. Despite inaccurate volume delineation, TF derived from 40% and COA contours could be reliable for their prognostic use. The TF that exhibited simultaneous added value and independence of lesion movement were ENG and ENT computed from the G-image. Their use is therefore recommended for heterogeneity quantification of lesions affected by respiratory motion.
引用
收藏
页码:652 / 668
页数:17
相关论文
共 40 条
[1]  
Bowen R, 2008, INT J RADIAT ONCOL, V70, P1229
[2]   The Effect of Small Tumor Volumes on Studies of Intratumoral Heterogeneity of Tracer Uptake [J].
Brooks, Frank J. ;
Grigsby, Perry W. .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (01) :37-42
[3]   Tumor Texture Analysis in PET: Where Do We Stand? [J].
Buvat, Irene ;
Orlhac, Fanny ;
Soussan, Michael .
JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (11) :1642-1644
[4]   A prospective investigation into the clinical impact of 4D-PET/CT in the characterisation of solitary pulmonary nodules [J].
Callahan, Jason ;
Kron, Tomas ;
Schneider, Michal E. ;
Hicks, Rodney J. .
CANCER IMAGING, 2014, 14 :24
[5]   Feasibility of a semi-automated contrast-oriented algorithm for tumor segmentation in retrospectively gated PET images: phantom and clinical validation [J].
Carles, Montserrat ;
Fechter, Tobias ;
Nemer, Ursula ;
Nanko, Norbert ;
Mix, Michael ;
Nestle, Ursula ;
Schaefer, Andrea .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (24) :9227-9251
[6]   Impact of 4D-18FDG-PET/CT imaging on target volume delineation in SBRT patients with central versus peripheral lung tumors. Multi-reader comparative study [J].
Chirindel, Alin ;
Adebahr, Sonja ;
Schuster, Daniel ;
Schimek-Jasch, Tanja ;
Schanne, Daniel H. ;
Nemer, Ursula ;
Mix, Michael ;
Meyer, Philipp ;
Grosu, Anca-Ligia ;
Brunner, Thomas ;
Nestle, Ursula .
RADIOTHERAPY AND ONCOLOGY, 2015, 115 (03) :335-341
[7]   The precision of textural analysis in 18F-FDG-PET scans of oesophageal cancer [J].
Doumou, Georgia ;
Siddique, Musib ;
Tsoumpas, Charalampos ;
Goh, Vicky ;
Cook, Gary J. .
EUROPEAN RADIOLOGY, 2015, 25 (09) :2805-2812
[8]   A programmable motion phantom for quality assurance of motion management in radiotherapy [J].
Dunn, L. ;
Kron, T. ;
Johnston, P. N. ;
McDermott, L. N. ;
Taylor, M. L. ;
Callahan, J. ;
Franich, R. D. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) :93-100
[9]   Exploring feature-based approaches in PET images for predicting cancer treatment outcomes [J].
El Naqa, I. ;
Grigsby, P. W. ;
Apte, A. ;
Kidd, E. ;
Donnelly, E. ;
Khullar, D. ;
Chaudhari, S. ;
Yang, D. ;
Schmitt, M. ;
Laforest, Richard ;
Thorstad, W. L. ;
Deasy, J. O. .
PATTERN RECOGNITION, 2009, 42 (06) :1162-1171
[10]  
Erdi YE, 1997, CANCER, V80, P2505, DOI 10.1002/(SICI)1097-0142(19971215)80:12+<2505::AID-CNCR24>3.3.CO