Estimation of human core temperature from sequential heart rate observations

被引:105
|
作者
Buller, Mark J. [1 ,4 ]
Tharion, William J. [1 ]
Cheuvront, Samuel N. [1 ]
Montain, Scott J. [1 ]
Kenefick, Robert W. [1 ]
Castellani, John [1 ]
Latzka, William A. [1 ]
Roberts, Warren S. [2 ]
Richter, Mark [3 ]
Jenkins, Odest Chadwicke [4 ]
Hoyt, Reed W. [1 ]
机构
[1] USA, Environm Med Res Inst, Natick, MA 01760 USA
[2] Def Sci & Technol Org, Melbourne, Vic, Australia
[3] Marine Corps Syst Command, Quantico, VA 22135 USA
[4] Brown Univ, Dept Comp Sci, Providence, RI 02912 USA
关键词
core body temperature; Kalman filter model; latent variable; core temperature surrogate; non-invasive sensors; HUMAN THERMOREGULATION; BODY-TEMPERATURE; STRAIN INDEX; EXERCISE; MODEL; HYPERHYDRATION; ESOPHAGEAL; PREDICTION; SIMULATION; BLADDER;
D O I
10.1088/0967-3334/34/7/781
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Core temperature (CT) in combination with heart rate (HR) can be a good indicator of impending heat exhaustion for occupations involving exposure to heat, heavy workloads, and wearing protective clothing. However, continuously measuring CT in an ambulatory environment is difficult. To address this problem we developed a model to estimate the time course of CT using a series of HR measurements as a leading indicator using a Kalman filter. The model was trained using data from 17 volunteers engaged in a 24 h military field exercise (air temperatures 24-36 degrees C, and 42%-97% relative humidity and CTs ranging from 36.0-40.0 degrees C). Validation data from laboratory and field studies (N = 83) encompassing various combinations of temperature, hydration, clothing, and acclimation state were examined using the Bland-Altman limits of agreement (LoA) method. We found our model had an overall bias of -0.03 +/- 0.32 degrees C and that 95% of all CT estimates fall within +/- 0.63 degrees C (> 52 000 total observations). While the model for estimating CT is not a replacement for direct measurement of CT (literature comparisons of esophageal and rectal methods average LoAs of +/- 0.58 degrees C) our results suggest it is accurate enough to provide practical indication of thermal work strain for use in the work place.
引用
收藏
页码:781 / 798
页数:18
相关论文
共 50 条
  • [1] Estimation of core body temperature from skin temperature, heat flux, and heart rate using a Kalman filter
    Welles, Alexander P.
    Xu, Xiaojiang
    Santee, William R.
    Looney, David P.
    Buller, Mark J.
    Potter, Adam W.
    Hoyt, Reed W.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 99 : 1 - 6
  • [2] Estimation of metabolic energy expenditure from core temperature using a human thermoregulatory model
    Welles, Alexander P.
    Buller, Mark J.
    Looney, David P.
    Rumpler, William V.
    Gribok, Andrei V.
    Hoyt, Reed W.
    JOURNAL OF THERMAL BIOLOGY, 2018, 72 : 44 - 52
  • [3] Validity of heart rate derived core temperature estimation during simulated firefighting tasks
    Agostinelli, Philip J.
    Linder, Braxton A.
    Frick, Katherine A.
    Bordonie, Nicholas C.
    Neal, Frances K.
    Sefton, JoEllen M.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [4] Estimation of melatonin level and core body temperature: heart rate and heart rate variability as circadian rhythm markers
    Eo, Yun Jae
    Park, Jingyu
    Kim, Seohyeon
    Lee, Keyong Nam
    Lee, Seung Min
    Kim, Dae Hwan
    Kim, Changwook
    Do, Young Rag
    BIOLOGICAL RHYTHM RESEARCH, 2022, 53 (11) : 1735 - 1752
  • [5] Comparisons of Core Temperature Between a Telemetric Pill and Heart Rate Estimated Core Temperature in Firefighters
    Pearson, Stephen J.
    Highlands, Brian
    Jones, Rebecca
    Matthews, Martyn J.
    SAFETY AND HEALTH AT WORK, 2022, 13 (01) : 99 - 103
  • [6] Individualized estimation of human core body temperature using noninvasive measurements
    Laxminarayan, Srinivas
    Rakesh, Vineet
    Oyama, Tatsuya
    Kazman, Josh B.
    Yanovich, Ran
    Ketko, Itay
    Epstein, Yoram
    Morrison, Shawnda
    Reifman, Jaques
    JOURNAL OF APPLIED PHYSIOLOGY, 2018, 124 (06) : 1387 - 1402
  • [7] Estimation of core body temperature by near-infrared imaging of vein diameter change in the dorsal hand
    Shourav, Mohiuddin Khan
    Salsabila, Syifa
    Lee, Joo-Young
    Kim, Jung Kyung
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (08) : 4700 - 4712
  • [8] Real-time human core temperature estimation methods and their application in the occupational field: A systematic review
    Falcone, Tiziana
    Cordella, Francesca
    Molinaro, Vincenzo
    Zollo, Loredana
    Del Ferraro, Simona
    MEASUREMENT, 2021, 183
  • [9] A real-time biphasic Kalman filter-based model for estimating human core temperature from heart rate measurements for application in the occupational field
    Falcone, Tiziana
    Del Ferraro, Simona
    Molinaro, Vincenzo
    Zollo, Loredana
    Lenzuni, Paolo
    FRONTIERS IN PUBLIC HEALTH, 2024, 12
  • [10] Ingestible pill for heart rate and core temperature measurement in cattle
    Martinez, Angel
    Schoenig, Scott
    Andresen, Daniel
    Warren, Steve
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 710 - 713