Influence of cage design on interbody fusion in a sheep cervical spine model

被引:60
|
作者
Kandziora, F [1 ]
Schollmeier, G [1 ]
Scholz, M [1 ]
Schaefer, J [1 ]
Scholz, A [1 ]
Schmidmaier, G [1 ]
Schröder, R [1 ]
Bail, H [1 ]
Duda, G [1 ]
Mittlmeier, T [1 ]
Haas, NP [1 ]
机构
[1] Humboldt Univ, Klinikum Charite, Strahlenklin & Poliklin, D-13353 Berlin, Germany
关键词
cervical spine; interbody cage; spinal fusion; sheep;
D O I
10.3171/spi.2002.96.3.0321
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The purpose of this study was to compare the characteristics of interbody fusion achieved using an autologous tricortical iliac crest bone graft with those of a cylinder- and a box-design cage in a sheep cervical spine model. This study was designed to determine whether there are differences between three interbody fusion procedures in: 1) ability to preserve postoperative distraction., 2) biomechanical stability, and 3) histological characteristics of intervertebral bone matrix formation. Methods. Twenty-four sheep underwent C3-4 discectomy and fusion in which the following were used: Group 1, autologous tricortical iliac crest bone graft (eight sheep); Group 2, titanium cylinder-design cage filled with autologous iliac crest bone graft (eight sheep); and Group 3, titanium box-design cage filled with autologous iliac crest graft (eight sheep). Radiography was performed pre- and postoperatively and after 1, 2, 4, 8, and 12 weeks. At the same time points, disc space height, intervertebral angle, and lordosis angle were measured. After 12 weeks. the sheep were killed, and fusion sites were evaluated by obtaining functional radiographs in flexion and extension, Quantitative computerized tomography scans were acquired to assess bone mineral density, bone mineral content, and bone callus volume. Biomechanical testing was performed in flexion, extension, axial rotation, and lateral bending. Stiffness, range of motion, neutral zone, and elastic zone were determined. Histomorphological and histomorphometric analyses were performed, and polychrome sequential labeling was used to determine the time frame of new bone formation. Over a 12-week period significantly higher values for disc space height and intervertebral angle were shown in cage-treated sheep than in those that received bone graft. Functional radiographic assessment revealed significantly lower residual flexion-extens ion movement in sheep with the cylinder cage-fixed spines than in those that received bone graft group. The cylinder-design cages showed significantly higher values for bone mineral content, bone callus content, and stiffness in axial rotation and lateral bending than the other cages or grafts. Histomorphometric evaluation and polychrome sequential labeling showed a more progressed bone matrix formation in the cylindrical cage group than in both other groups. Conclusions. Compared with the tricortical bone graft, both cages showed significantly better distractive properties. The cylindrical cage demonstrated a significantly higher biomechanical stiffness and an accelerated interbody fusion compared with the box-design cage and the tricortical bone graft, The differences in bone matrix formation within both cages were the result of the significantly lower stress shielding on the bone graft by the cylinder-design cage.
引用
收藏
页码:321 / 332
页数:12
相关论文
共 50 条
  • [41] An update of interbody cages for spine fusion surgeries: from shape design to materials
    Li, Guangshen
    Yang, Lei
    Wu, Gang
    Qian, Zhanyang
    Li, Haijun
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (12) : 977 - 989
  • [42] Porous interbody fusion cage design via topology optimization and biomechanical performance analysis
    Li, Nan
    Zhang, Yang
    Tang, Qiaohong
    Wang, Hongkun
    He, Da
    Yao, Yan
    Fan, Yubo
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (06) : 650 - 659
  • [43] A prospective randomized comparison of PEEK cage containing calcium sulphate or demineralized bone matrix with autograft in anterior cervical interbody fusion
    Xie, Youzhuan
    Li, Hua
    Yuan, Junjie
    Fu, Lingjie
    Yang, Jianwei
    Zhang, Pu
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (06) : 1129 - 1136
  • [44] Dose-dependent effects of combined IGF-I and TGF-β1 application in a sheep cervical spine fusion model
    F. Kandziora
    R. Pflugmacher
    M. Scholz
    J. Schäfer
    G. Schollmeier
    G. Schmidmaier
    G. Duda
    M. Raschke
    N. P. Haas
    European Spine Journal, 2003, 12 : 464 - 473
  • [45] Outcome analyses of interbody titanium cage fusion used in the anterior discectomy for cervical degenerative disc disease
    Hwang, SL
    Hwang, YF
    Lieu, AS
    Lin, CL
    Kuo, TH
    Su, YF
    Howng, SL
    Lee, KS
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (04): : 326 - 331
  • [46] Comparison of BMP-2 and combined IGF-I/TGF-β1 application in a sheep cervical spine fusion model
    Kandziora, F
    Pflugmacher, R
    Scholz, M
    Knispel, C
    Hiller, T
    Schollmeier, G
    Bail, H
    Schmidmaier, G
    Duda, G
    Raschke, M
    Haas, NP
    EUROPEAN SPINE JOURNAL, 2002, 11 (05) : 482 - 493
  • [47] Dose-dependent effects of combined IGF-I and TGF-β1 application in a sheep cervical spine fusion model
    Kandziora, F
    Pflugmacher, R
    Scholz, M
    Schäfer, J
    Schollmeier, G
    Schmidmaier, G
    Duda, G
    Raschke, M
    Haas, NP
    EUROPEAN SPINE JOURNAL, 2003, 12 (05) : 464 - 473
  • [48] Does interbody cage lordosis impact actual segmental lordosis achieved in minimally invasive lumbar spine fusion?
    Lovecchio, Francis C.
    Vaishnav, Avani S.
    Steinhaus, Michael E.
    Othman, Yahya A.
    Gang, Catherine Himo
    Iyer, Sravisht
    McAnany, Steven J.
    Albert, Todd J.
    Qureshi, Sheeraz A.
    NEUROSURGICAL FOCUS, 2020, 49 (03) : 1 - 8
  • [49] POSTERIOR LUMBAR INTERBODY FUSION USING THE RAY THREADED FUSION CAGE
    LECLERCQ, TA
    JOURNAL OF CLINICAL NEUROSCIENCE, 1995, 2 (02) : 129 - 131
  • [50] Lumbar fusion for lytic spondylolisthesis: Is an interbody cage necessary?
    Boktor, Joseph
    Ninan, Tishi
    Pockett, Rhys
    Collins, Iona
    Sultan, Ahmed
    Koptan, Wael
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2018, 9 (02) : 101 - 106