Experimental study on thermal performance of the tunnel with active heating system in cold region

被引:0
作者
Ma, Chengjin [1 ]
Yang, Runlin [1 ]
Zhang, Shuai [1 ]
机构
[1] Univ Sci & Technol Beijing, Sch Civil & Resource Engn, Dept Civil Engn, Beijing 100083, Peoples R China
来源
PROCEEDINGS OF THE 2017 3RD INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT SCIENCE AND MATERIALS (IFEESM 2017) | 2017年 / 120卷
关键词
tunnel; thermal effect; experimental study; cold region;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the cold region, the seasonal freezing and thawing for the pore water in the rock or the soil are very likely to occur repeatedly. Engineering practices show that: in the service period, more than 80% of the tunnels have different degrees of frost damage. Hence, the frost-resisting problem must be taken into account. In this paper, the Jinzhangzi tunnel was chosen as a target project and a serious of the thermal tests were carried out. Experimental result the proposed heating system can suppress occurence of the frost damage for the target tunnel.
引用
收藏
页码:271 / 274
页数:4
相关论文
共 8 条
[1]  
Chen X.B., 2011, FREEZING EFFECT FDN, P10
[2]  
Jia Xiangjun, 1999, FOREIGN HIGHWAYS, V19, P51
[3]  
The Institute of Environmental and Engineering research national key Laboratory of frozen soil engineering, 2000, CAS, V10, P241
[4]  
The People's Republic of China industry standards, 2005, COD DES RAILW TUNN
[5]  
Wu Z., 2003, TUNNEL ENG COLD REGI
[6]  
Xu Yunzu, 2010, FROZEN SOIL PHYS, P1
[7]  
Zhang Z., 2004, Modern Tunnel. Technol., V41, P1
[8]  
Zhou Youwu, 2000, CHINESE FROZEN SOIL, P55