A contour-guided deformable image registration algorithm for adaptive radiotherapy

被引:38
作者
Gu, Xuejun [1 ,2 ,3 ]
Dong, Bin [1 ,2 ,4 ]
Wang, Jing [3 ]
Yordy, John [3 ]
Mell, Loren [1 ,2 ]
Jia, Xun [1 ,2 ]
Jiang, Steve B. [1 ,2 ]
机构
[1] Univ Calif San Diego, Ctr Adv Radiotherapy Technol, La Jolla, CA 92037 USA
[2] Univ Calif San Diego, Dept Radiat Med & Appl Sci, La Jolla, CA 92037 USA
[3] Univ Texas SW Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
[4] Univ Arizona, Dept Math, Tucson, AZ 85721 USA
关键词
CONE-BEAM CT; COMPUTED-TOMOGRAPHY IMAGES; RESPIRATORY MOTION; RADIATION-THERAPY; MULTI-INSTITUTION; DEMONS ALGORITHM; ACCURACY; SEGMENTATION; PROPAGATION; MODEL;
D O I
10.1088/0031-9155/58/6/1889
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In adaptive radiotherapy, deformable image registration is often conducted between the planning CT and treatment CT (or cone beam CT) to generate a deformation vector field (DVF) for dose accumulation and contour propagation. The auto-propagated contours on the treatment CT may contain relatively large errors, especially in low-contrast regions. A clinician's inspection and editing of the propagated contours are frequently needed. The edited contours are able to meet the clinical requirement for adaptive therapy; however, the DVF is still inaccurate and inconsistent with the edited contours. The purpose of this work is to develop a contour-guided deformable image registration (CG-DIR) algorithm to improve the accuracy and consistency of the DVF for adaptive radiotherapy. Incorporation of the edited contours into the registration algorithm is realized by regularizing the objective function of the original demons algorithm with a term of intensity matching between the delineated structures set pairs. The CG-DIR algorithm is implemented on computer graphics processing units (GPUs) by following the original GPU-based demons algorithm computation framework (Gu et al 2010 Phys Med Biol. 55 207-219). The performance of CG-DIR is evaluated on five clinical head-and-neck and one pelvic cancer patient data. It is found that compared with the original demons, CG-DIR improves the accuracy and consistency of the DVF, while retaining similar high computational efficiency.
引用
收藏
页码:1889 / 1901
页数:13
相关论文
共 35 条
[1]   4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis [J].
Boldea, Vlad ;
Sharp, Gregory C. ;
Jiang, Steve B. ;
Sarrut, David .
MEDICAL PHYSICS, 2008, 35 (03) :1008-1018
[2]   Accuracy of finite element model-based multi-organ deformable image registration [J].
Brock, KK ;
Sharpe, MB ;
Dawson, LA ;
Kim, SM ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (06) :1647-1659
[3]   RESULTS OF A MULTI-INSTITUTION DEFORMABLE REGISTRATION ACCURACY STUDY (MIDRAS) [J].
Brock, Kristy K. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (02) :583-596
[4]   Isotropic energies, filters and splines for vector field regularization [J].
Cachier, P ;
Ayache, N .
JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2004, 20 (03) :251-265
[5]  
Cachier P., 1999, RR3706 INRIA
[6]   Auto-propagation of contours for adaptive prostate radiation therapy [J].
Chao, Ming ;
Xie, Yaoqin ;
Xing, Lei .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) :4533-4542
[7]   An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing [J].
Ehrhardt, Jan ;
Werner, Rene ;
Saering, Dennis ;
Frenzel, Thorsten ;
Lu, Wei ;
Low, Daniel ;
Handels, Heinz .
MEDICAL PHYSICS, 2007, 34 (02) :711-721
[8]   Implementation and evaluation of various demons deformable image registration algorithms on a GPU [J].
Gu, Xuejun ;
Pan, Hubert ;
Liang, Yun ;
Castillo, Richard ;
Yang, Deshan ;
Choi, Dongju ;
Castillo, Edward ;
Majumdar, Amitava ;
Guerrero, Thomas ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01) :207-219
[9]   Medical image registration [J].
Hill, DLG ;
Batchelor, PG ;
Holden, M ;
Hawkes, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :R1-R45
[10]   A review of geometric transformations for nonrigid body registration [J].
Holden, Mark .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (01) :111-128