The X-ray Microcalorimeter Spectrometer onboard of Athena

被引:8
|
作者
den Herder, J. W. [1 ]
Bagnali, D.
Bandler, S.
Barbera, M.
Barcons, X.
Barret, D.
Bastia, P.
Bisotti, M.
Boyce, K.
Cara, C.
Ceballos, M.
Corcione, L.
Cobo, B.
Colasanti, L.
de Plaa, J. [1 ]
DiPirro, M.
Doriese, W. B.
Ezoe, Y.
Fujimoto, R.
Gatti, F.
Gottardi, L. [1 ]
Guttridge, P.
den Hartog, R. [1 ]
Hepburn, I.
Kelley, R.
Irwin, K.
Ishisaki, Y.
Kilbourne, C.
de Korte, P. A. J. [1 ]
van der Kuur, J. [1 ]
Lotti, S.
Macculi, C.
Mitsuda, K.
Mineo, T.
Natalucci, L.
Ohashi, T.
Page, M.
Paltani, S.
Perinati, E.
Piro, L.
Pigot, C.
Porter, F. S.
Rauw, G.
Ravera, L.
Renotte, E.
Sauvageot, J-L.
Schmid, C.
Sciortino, S.
Shirron, P.
Takei, Y.
机构
[1] SRON Netherlands Inst Space Res, SRON, Sorbonnelaan 2, NL-3854 CA Utrecht, Netherlands
关键词
X-ray; missions; micro-calorimeter; Athena;
D O I
10.1117/12.924269
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
One of the instruments on the Advanced Telescope for High-Energy Astrophysics (Athena) which was one of the three missions under study as one of the L-class missions of ESA, is the X-ray Microcalorimeter Spectrometer (XMS). This instrument, which will provide high-spectral resolution images, is based on X-ray micro-calorimeters with Transition Edge Sensor (TES) and absorbers that consist of metal and semi-metal layers and a multiplexed SQUID readout. The array (32 x 32 pixels) provides an energy resolution of < 3 eV. Due to the large collection area of the Athena optics, the XMS instrument must be capable of processing high counting rates, while maintaining the spectral resolution and a low deadtime. In addition, an anti-coincidence detector is required to suppress the particle-induced background. Compared to the requirements for the same instrument on IXO, the performance requirements have been relaxed to fit into the much more restricted boundary conditions of Athena. In this paper we illustrate some of the science achievable with the instrument. We describe the results of design studies for the focal plane assembly and the cooling systems. Also, the system and its required spacecraft resources will be given.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] X-ray fluorescence spectrometer onboard Muses-C
    Okada, T
    Kato, M
    Fujimura, A
    Tsunemi, H
    Kitamoto, S
    SAMPLE RETURN MISSIONS TO SMALL BODIES, 2000, 25 (02): : 345 - 348
  • [22] Toward a 2-eV microcalorimeter x-ray spectrometer for Constellation-X
    Stahle, CK
    Bandler, SR
    Barbee, T
    Beeman, J
    Brekosky, RP
    Cabrera, B
    Cunningham, M
    Deiker, S
    Figueroa-Feliciano, E
    Finkbeiner, FM
    Frank, M
    Gendreau, KC
    Haller, E
    Hilton, GC
    Irwin, KD
    Kelley, RL
    Labov, SE
    Li, MJ
    Madden, N
    Martinis, JM
    McCammon, D
    Nam, S
    Porter, FS
    Schnopper, H
    Silver, EH
    Szymkowiak, AE
    Tucker, GS
    Walker, A
    Wollman, DA
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 82 - 93
  • [23] In-Orbit Performance of the Digital Electronics for the X-Ray Microcalorimeter Onboard the Hitomi Satellite
    Tsujimoto, M.
    Tashiro, M. S.
    Ishisaki, Y.
    Yamada, S.
    Seta, H.
    Mitsuda, K.
    Boyce, K. R.
    Eckart, M. E.
    Kilbourne, C. A.
    Leutenegger, M. A.
    Porter, F. S.
    Kelley, R. L.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2018, 193 (3-4) : 505 - 511
  • [24] In-Orbit Performance of the Digital Electronics for the X-Ray Microcalorimeter Onboard the Hitomi Satellite
    M. Tsujimoto
    M. S. Tashiro
    Y. Ishisaki
    S. Yamada
    H. Seta
    K. Mitsuda
    K. R. Boyce
    M. E. Eckart
    C. A. Kilbourne
    M. A. Leutenegger
    F. S. Porter
    R. L. Kelley
    Journal of Low Temperature Physics, 2018, 193 : 505 - 511
  • [25] TES-Based X-ray Microcalorimeter Performances Under AC Bias and FDM for Athena
    Akamatsu, H.
    Gottardi, L.
    de Vries, C. P.
    Adams, J. S.
    Bandler, S. R.
    Bruijn, M. P.
    Chervenak, J. A.
    Eckart, M. E.
    Finkbeiner, F. M.
    Gao, J. R.
    den Herder, J. -W.
    den Hartog, R.
    Hoevers, H.
    Kelley, R. E.
    Khosropanah, P.
    Kilbourne, C. A.
    van der Kuur, J.
    Lee, S. -J.
    van den Linden, A. J.
    Porter, F. S.
    Ravensberg, K.
    Sadleir, J. E.
    Smith, S. J.
    Suzuki, T.
    Wassell, E. J.
    Kiviranta, M.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2016, 184 (1-2) : 436 - 442
  • [26] TES-Based X-ray Microcalorimeter Performances Under AC Bias and FDM for Athena
    H. Akamatsu
    L. Gottardi
    C. P. de Vries
    J. S. Adams
    S. R. Bandler
    M. P. Bruijn
    J. A. Chervenak
    M. E. Eckart
    F. M. Finkbeiner
    J. R. Gao
    J.-W. den Herder
    R. den Hartog
    H. Hoevers
    R. E. Kelley
    P. Khosropanah
    C. A. Kilbourne
    J. van der Kuur
    S.-J. Lee
    A. J. van den Linden
    F. S. Porter
    K. Ravensberg
    J. E. Sadleir
    S. J. Smith
    T. Suzuki
    E. J. Wassell
    M. Kiviranta
    Journal of Low Temperature Physics, 2016, 184 : 436 - 442
  • [27] A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science
    Doriese, W. B.
    Abbamonte, P.
    Alpert, B. K.
    Bennett, D. A.
    Denison, E. V.
    Fang, Y.
    Fischer, D. A.
    Fitzgerald, C. P.
    Fowler, J. W.
    Gard, J. D.
    Hays-Wehle, J. P.
    Hilton, G. C.
    Jaye, C.
    McChesney, J. L.
    Miaja-Avila, L.
    Morgan, K. M.
    Joe, Y. I.
    O'Neil, G. C.
    Reintsema, C. D.
    Rodolakis, F.
    Schmidt, D. R.
    Tatsuno, H.
    Uhlig, J.
    Vale, L. R.
    Ullom, J. N.
    Swetz, D. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (05):
  • [28] Monitoring of The Solar Activity with X-Ray Spectrometer onboard of the Yarilo CubeSat
    Dyatkov, S. Yu
    Pertsov, A. A.
    Erkhova, N. F.
    Kirichenko, A. S.
    Tenenbaum, S. M.
    XLIV ACADEMIC SPACE CONFERENCE: DEDICATED TO THE MEMORY OF ACADEMICIAN S.P. KOROLEV AND OTHER OUTSTANDING RUSSIAN SCIENTISTS - PIONEERS OF SPACE EXPLORATION, 2021, 2318
  • [29] Fabrication of an X-ray microcalorimeter with an electrodeposited X-ray microabsorber
    Kudo, H
    Sato, H
    Nakamura, T
    Arakawa, T
    Goto, E
    Shoji, S
    Homma, T
    Osaka, T
    Mitsuda, K
    Fujimoto, R
    Iyomoto, N
    Audley, MD
    Miyazaki, T
    Oshima, T
    Yamazaki, M
    Futamoto, K
    Takei, Y
    Ishisaki, Y
    Kagei, T
    Hiroike, T
    Ohashi, T
    Yamasaki, NY
    Kushino, A
    Kuroda, Y
    Onishi, M
    Goto, M
    LOW TEMPERATURE DETECTORS, 2002, 605 : 235 - 238
  • [30] Mechanical Cryocooler Noise Observed in the Ground Testing of the Resolve X-ray Microcalorimeter Onboard XRISM
    Imamura, R.
    Awaki, H.
    Tsujimoto, M.
    Yamada, S.
    Porter, F. S.
    Kilbourne, C. A.
    Kelley, R. L.
    Takei, Y.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2023, 211 (5-6) : 426 - 433