Biomechanical Properties of the Cornea Measured With the Dynamic Scheimpflug Analyzer in Young Healthy Adults

被引:5
作者
Lee, Hun [1 ,2 ]
Kang, David Sung Yong [3 ]
Ha, Byoung Jin [3 ]
Choi, Jin Young [2 ]
Kim, Eung Kweon [2 ,4 ]
Seo, Kyoung Yul [2 ]
Kim, Ha Yan [5 ]
Kim, Tae-im [2 ]
机构
[1] Catholic Kwandong Univ, Coll Med, Int St Marys Hosp, Dept Ophthalmol, Inchon, South Korea
[2] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul, South Korea
[3] Eyereum Eye Clin, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Corneal Dystrophy Res Inst, Dept Ophthalmol, Seoul, South Korea
[5] Yonsei Univ, Coll Med, Biostat Collaborat Unit, Seoul, South Korea
关键词
corneal biomechanical property; dynamic Scheimpflug analyzer; young healthy adults; normal value database; OCULAR RESPONSE ANALYZER; IN-SITU KERATOMILEUSIS; INTRAOCULAR-PRESSURE; CROSS-LINKING; NORMAL EYES; PARAMETERS; KERATOCONUS; NONCONTACT;
D O I
10.1097/ICO.0000000000001001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the biomechanical properties of the cornea using the dynamic Scheimpflug analyzer in young healthy adults. Methods: This prospective cross-sectional population study included 944 eyes of 472 participants aged 20 to 40 years. Participants underwent ophthalmic investigations, including evaluation of biomechanical properties of the cornea using the dynamic Scheimpflug analyzer, manifest refraction, and measurements of keratometric values by autokeratometry, intraocular pressure (IOP) by noncontact tonometer, central corneal thickness (CCT) by ultrasound, and white-to-white distance by Scheimpflug tomography. Statistical analyses included determination of the reference interval with a bootstrapping method, linear quantile mixed-effects model, and Spearman correlation analysis between the corneal biomechanical parameters and other variables (age, manifest refraction spherical equivalent, CCT, IOP, white-to-white, and keratometric values). Results: The 90% CIs of all corneal biomechanical parameters demonstrated that the ranges of the 90% CIs for the reference data were almost identical with and without bootstrapping. Quantile regression to determine the fifth, 50th, and 95th percentiles of each corneal biomechanical parameter supported the findings from the nonparametric method with the 90% CIs. Correlation analysis showed significant correlations between the parameters and variables, but there was a relatively high Spearman correlation coefficient in the case of the correlations with the CCT and IOP. Conclusions: Using data from a large population of young healthy adults, we developed a database of normal values for multiple corneal biomechanical parameters obtained from the dynamic Scheimpflug analyzer. We conclude that the biomechanical properties of the cornea are influenced by the CCT and IOP.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 43 条
  • [31] Effect of mydriasis induced by topical 0.5% tropicamide instillation on the corneal biomechanical properties in healthy individuals measured by ocular response analyzer
    Oltulu, Refik
    Satirtav, Gunhal
    Altunkaya, Orhan
    Bitirgen, Gulfidan
    Okka, Mehmet
    CUTANEOUS AND OCULAR TOXICOLOGY, 2015, 34 (01) : 35 - 37
  • [32] Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry
    Pedersen, Iben Bach
    Bak-Nielsen, Sashia
    Vestergaard, Anders Hojslet
    Ivarsen, Anders
    Hjortdal, Jesper
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (08) : 1329 - 1335
  • [33] Effect of accelerated corneal crosslinking combined with transepithelial photorefractive keratectomy on dynamic corneal response parameters and biomechanically corrected intraocular pressure measured with a dynamic Scheimpflug analyzer in healthy myopic patients
    Lee, Hun
    Roberts, Cynthia J.
    Ambrosio, Renato, Jr.
    Elsheikh, Ahmed
    Kang, David Sung Yong
    Kim, Tae-im
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (07) : 937 - 945
  • [34] Evaluation of Corneal Biomechanical Properties Measured By Ocular Response Analyzer in Cases with Rheumatoid Arthritis
    Altinkaynak, Hasan
    Kara, Necip
    Baz, Okkes
    Celik, Yonca Cagatay
    Bozkurt, Ercument
    Yazici, Ahmet Taylan
    Demirok, Ahmet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (03): : 167 - 170
  • [35] Evaluation of corneal biomechanical properties in glaucoma and control patients by dynamic Scheimpflug corneal imaging technology
    Coste, V.
    Schweitzer, C.
    Paya, C.
    Touboul, D.
    Korobelnik, J. -F.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2015, 38 (06): : 504 - 513
  • [36] Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry
    Iben Bach Pedersen
    Sashia Bak-Nielsen
    Anders Højslet Vestergaard
    Anders Ivarsen
    Jesper Hjortdal
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1329 - 1335
  • [37] Changes in Biomechanical Properties of the Cornea and Intraocular Pressure After Myopic Laser In Situ Keratomileusis Using a Femtosecond Laser for Flap Creation Determined Using Ocular Response Analyzer and Goldmann Applanation Tonometry
    Shin, Jonghoon
    Kim, Tae Won
    Park, Soo Jeong
    Yoon, Min
    Lee, Ji Woong
    JOURNAL OF GLAUCOMA, 2015, 24 (03) : 195 - 201
  • [38] The Relationship Between Serum Biochemical Variables and Corneal Biomechanics Measured by Corvis ST Among Healthy Young Adults
    Li, Dan-Lin
    Liu, Min-Xin
    Zheng, Ya-Jie
    Qin, Yu
    Ma, Rong
    Liang, Gang
    Pan, Chen-Wei
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2025, 14 (02):
  • [40] Assessment of intraocular pressure measured by Reichert Ocular Response Analyzer, Goldmann Applanation Tonometry, and Dynamic Contour Tonometry in healthy individuals
    Ouyang, Ping-Bo
    Li, Cong-Yi
    Zhu, Xiao-Hua
    Duan, Xuan-Chu
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (01) : 102 - 107