Biomechanical Properties of the Cornea Measured With the Dynamic Scheimpflug Analyzer in Young Healthy Adults

被引:5
|
作者
Lee, Hun [1 ,2 ]
Kang, David Sung Yong [3 ]
Ha, Byoung Jin [3 ]
Choi, Jin Young [2 ]
Kim, Eung Kweon [2 ,4 ]
Seo, Kyoung Yul [2 ]
Kim, Ha Yan [5 ]
Kim, Tae-im [2 ]
机构
[1] Catholic Kwandong Univ, Coll Med, Int St Marys Hosp, Dept Ophthalmol, Inchon, South Korea
[2] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul, South Korea
[3] Eyereum Eye Clin, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Corneal Dystrophy Res Inst, Dept Ophthalmol, Seoul, South Korea
[5] Yonsei Univ, Coll Med, Biostat Collaborat Unit, Seoul, South Korea
关键词
corneal biomechanical property; dynamic Scheimpflug analyzer; young healthy adults; normal value database; OCULAR RESPONSE ANALYZER; IN-SITU KERATOMILEUSIS; INTRAOCULAR-PRESSURE; CROSS-LINKING; NORMAL EYES; PARAMETERS; KERATOCONUS; NONCONTACT;
D O I
10.1097/ICO.0000000000001001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the biomechanical properties of the cornea using the dynamic Scheimpflug analyzer in young healthy adults. Methods: This prospective cross-sectional population study included 944 eyes of 472 participants aged 20 to 40 years. Participants underwent ophthalmic investigations, including evaluation of biomechanical properties of the cornea using the dynamic Scheimpflug analyzer, manifest refraction, and measurements of keratometric values by autokeratometry, intraocular pressure (IOP) by noncontact tonometer, central corneal thickness (CCT) by ultrasound, and white-to-white distance by Scheimpflug tomography. Statistical analyses included determination of the reference interval with a bootstrapping method, linear quantile mixed-effects model, and Spearman correlation analysis between the corneal biomechanical parameters and other variables (age, manifest refraction spherical equivalent, CCT, IOP, white-to-white, and keratometric values). Results: The 90% CIs of all corneal biomechanical parameters demonstrated that the ranges of the 90% CIs for the reference data were almost identical with and without bootstrapping. Quantile regression to determine the fifth, 50th, and 95th percentiles of each corneal biomechanical parameter supported the findings from the nonparametric method with the 90% CIs. Correlation analysis showed significant correlations between the parameters and variables, but there was a relatively high Spearman correlation coefficient in the case of the correlations with the CCT and IOP. Conclusions: Using data from a large population of young healthy adults, we developed a database of normal values for multiple corneal biomechanical parameters obtained from the dynamic Scheimpflug analyzer. We conclude that the biomechanical properties of the cornea are influenced by the CCT and IOP.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 43 条
  • [21] Dynamic Scheimpflug Ocular Biomechanical Parameters in Healthy and Medically Controlled Glaucoma Eyes
    Miki, Atsuya
    Yasukura, Yuichi
    Weinreb, Robert N.
    Yamada, Tomomi
    Koh, Shizuka
    Asai, Tomoko
    Ikuno, Yasushi
    Maeda, Naoyuki
    Nishida, Kohji
    JOURNAL OF GLAUCOMA, 2019, 28 (07) : 588 - 592
  • [22] Evaluation of corneal biomechanical properties using the ocular response analyzer and the dynamic Scheimpflug-Analyzer Corvis ST in high pressure and normal pressure open-angle glaucoma patients
    Ramm, Lisa
    Herber, Robert
    Lorenz, Georg
    Jasper, Carolin S.
    Pillunat, Lutz E.
    Pillunat, Karin R.
    PLOS ONE, 2023, 18 (01):
  • [23] A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
    Lopez-Munoz, Alfredo
    Lopez-Castano, Isabel
    Torres-Parejo, Ursula
    Garcia-Romera, Marta-C.
    LIFE-BASEL, 2023, 13 (12):
  • [24] Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based Tonometer
    Ali, Noor Q.
    Patel, Dipika V.
    McGhee, Charles N. J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) : 3651 - 3659
  • [25] Introduction of Two Novel Stiffness Parameters and Interpretation of Air Puff-Induced Biomechanical Deformation Parameters With a Dynamic Scheimpflug Analyzer
    Roberts, Cynthia J.
    Mahmoud, Ashraf M.
    Bons, Jeffrey P.
    Hossain, Arif
    Elsheikh, Ahmed
    Vinciguerra, Riccardo
    Vinciguerra, Paolo
    Ambrosio, Renato, Jr.
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (04) : 266 - +
  • [26] Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties
    Ambrosio, Renato, Jr.
    Ramos, Isaac
    Luz, Allan
    Faria, Fernando Correa
    Steinmueller, Andreas
    Krug, Matthias
    Belin, Michael W.
    Roberts, Cynthia Jane
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2013, 72 (02) : 99 - 102
  • [27] Correlations between corneal biomechanical properties measured with the Ocular Response Analyzer and ICare rebound tonometry
    Martins Jorge, Jorge Manuel
    Gonzalez-Meijome, Jose M.
    Queiros, Antonio
    Fernandes, Paulo
    Parafita, Manuel A.
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 442 - 448
  • [28] Dynamic Scheimpflug Analyzer (Corvis ST) for measurement of corneal biomechanical parameters. A praxis-related overview
    Herber, R.
    Terai, N.
    Pillunat, K. R.
    Raiskup, F.
    Pillunat, L. E.
    Spoerl, E.
    OPHTHALMOLOGE, 2018, 115 (08): : 635 - 643
  • [29] Measurement of Corneal Biomechanical Properties using Corneal Visualisation Scheimpflug Technology and Ocular Response Analyser in Healthy Saudi Female Adults: A Cross-sectional Study
    Maqsood, Farah
    Aldossari, Noura
    Al Matrafi, Menwah
    Amina, Musarat
    Bawazir, Maram m
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (12) : NC1 - NC6
  • [30] Evaluation of Corneal Biomechanical Properties Measured by Ocular Response Analyzer in Eyes with Pterygium
    Kara, Necip
    Baz, Okkes
    Bozkurt, Ercument
    Yazici, Ahmet Taylan
    Demirok, Ahmet
    Yilmaz, Omer Faruk
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (02): : 94 - 97