Biomechanical Properties of the Cornea Measured With the Dynamic Scheimpflug Analyzer in Young Healthy Adults

被引:5
|
作者
Lee, Hun [1 ,2 ]
Kang, David Sung Yong [3 ]
Ha, Byoung Jin [3 ]
Choi, Jin Young [2 ]
Kim, Eung Kweon [2 ,4 ]
Seo, Kyoung Yul [2 ]
Kim, Ha Yan [5 ]
Kim, Tae-im [2 ]
机构
[1] Catholic Kwandong Univ, Coll Med, Int St Marys Hosp, Dept Ophthalmol, Inchon, South Korea
[2] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul, South Korea
[3] Eyereum Eye Clin, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Corneal Dystrophy Res Inst, Dept Ophthalmol, Seoul, South Korea
[5] Yonsei Univ, Coll Med, Biostat Collaborat Unit, Seoul, South Korea
关键词
corneal biomechanical property; dynamic Scheimpflug analyzer; young healthy adults; normal value database; OCULAR RESPONSE ANALYZER; IN-SITU KERATOMILEUSIS; INTRAOCULAR-PRESSURE; CROSS-LINKING; NORMAL EYES; PARAMETERS; KERATOCONUS; NONCONTACT;
D O I
10.1097/ICO.0000000000001001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the biomechanical properties of the cornea using the dynamic Scheimpflug analyzer in young healthy adults. Methods: This prospective cross-sectional population study included 944 eyes of 472 participants aged 20 to 40 years. Participants underwent ophthalmic investigations, including evaluation of biomechanical properties of the cornea using the dynamic Scheimpflug analyzer, manifest refraction, and measurements of keratometric values by autokeratometry, intraocular pressure (IOP) by noncontact tonometer, central corneal thickness (CCT) by ultrasound, and white-to-white distance by Scheimpflug tomography. Statistical analyses included determination of the reference interval with a bootstrapping method, linear quantile mixed-effects model, and Spearman correlation analysis between the corneal biomechanical parameters and other variables (age, manifest refraction spherical equivalent, CCT, IOP, white-to-white, and keratometric values). Results: The 90% CIs of all corneal biomechanical parameters demonstrated that the ranges of the 90% CIs for the reference data were almost identical with and without bootstrapping. Quantile regression to determine the fifth, 50th, and 95th percentiles of each corneal biomechanical parameter supported the findings from the nonparametric method with the 90% CIs. Correlation analysis showed significant correlations between the parameters and variables, but there was a relatively high Spearman correlation coefficient in the case of the correlations with the CCT and IOP. Conclusions: Using data from a large population of young healthy adults, we developed a database of normal values for multiple corneal biomechanical parameters obtained from the dynamic Scheimpflug analyzer. We conclude that the biomechanical properties of the cornea are influenced by the CCT and IOP.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 43 条
  • [1] Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes
    Lee, Hun
    Kang, David Sung Yong
    Ha, Byoung Jin
    Choi, Jin Young
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Tae-im
    YONSEI MEDICAL JOURNAL, 2018, 59 (09) : 1115 - 1122
  • [2] Corneal Biomechanical Properties in Myopic Eyes Measured by a Dynamic Scheimpflug Analyzer
    Wang, Jingyi
    Li, Ying
    Jin, Yumei
    Yang, Xue
    Zhao, Chan
    Long, Qin
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [3] Effect of Prostaglandin Analogues on Corneal Biomechanical Parameters Measured With a Dynamic Scheimpflug Analyzer
    Yasukura, Yuichi
    Miki, Atsuya
    Maeda, Naoyuki
    Koh, Shizuka
    Nishida, Kohji
    JOURNAL OF GLAUCOMA, 2021, 30 (11) : 996 - 1000
  • [4] Corneal biomechanical properties after soft contact lens wear measured on a dynamic Scheimpflug analyzer: A before and after study
    Peyman, A.
    Ghoreishi, M.
    Hashemi-Estabragh, S-S
    Mirmohammadkhani, M.
    Mohammadinia, M.
    Pourazizi, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (03): : 391 - 396
  • [5] Effect of prostaglandin analogues on the biomechanical corneal properties in patients with open-angle glaucoma and ocular hypertension measured with dynamic scheimpflug analyzer
    Isabel Martinez-Sanchez, Marta
    Bolivar, Gema
    Sideroudi, Haris
    Teus, Miguel A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (12) : 3927 - 3933
  • [6] Corneal biomechanical properties in 3 corneal transplantation techniques with a dynamic Scheimpflug analyzer
    Maeda, Naoyuki
    Ueki, Ryotaro
    Fuchihata, Mutsumi
    Fujimoto, Hisataka
    Koh, Shizuka
    Nishida, Kohji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (06) : 483 - 489
  • [7] Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology
    He, Miao
    Ding, Hui
    He, Hong
    Zhang, Chi
    Liu, Liangping
    Zhong, Xingwu
    BMC OPHTHALMOLOGY, 2017, 17
  • [8] Factors Associated With Corneal Deformation Responses Measured With a Dynamic Scheimpflug Analyzer
    Miki, Atsuya
    Maeda, Naoyuki
    Ikuno, Yasushi
    Asai, Tomoko
    Hara, Chikako
    Nishida, Kohji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (01) : 538 - 544
  • [9] Assessment of corneal biomechanical parameters in healthy and keratoconic eyes using dynamic bidirectional applanation device and dynamic Scheimpflug analyzer
    Herber, Robert
    Ramm, Lisa
    Spoerl, Eberhard
    Raiskup, Frederik
    Pillunat, Lutz E.
    Terai, Naim
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 778 - 788
  • [10] Effect of prostaglandin analogues on the biomechanical corneal properties in patients with open-angle glaucoma and ocular hypertension measured with dynamic scheimpflug analyzer
    Marta Isabel Martínez-Sánchez
    Gema Bolívar
    Haris Sideroudi
    Miguel A. Teus
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 3927 - 3933