Survey on the indoor air of the underground space

被引:0
|
作者
Qu, GL [1 ]
Yue, LJ [1 ]
Min, YQ [1 ]
Ma, GH [1 ]
Li, FR [1 ]
机构
[1] Inst Chem Def, Beijing 102205, Peoples R China
关键词
the indoor air of the underground space; formaldehyde; benzene; toluene; xylene; volatile organic compounds;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The volatile organic compounds (VOCs) in different underground spaces were surveyed, the results showed that more than 60 kinds of VOCs were ubiquitous. On this basis, aiming at the underground marks, the hotels, the parks, the offices and the subway, the further quantitative analysis was processed. The quantitative analysis results indicated that organic compounds such as formaldehyde, benzene, toluene and xylene etc. were the major pollutants in the underground space. According to the limit concentration of formaldehyde, benzene, toluene and xylene in the Quality Standards of Indoor Air (GB/T18883-2002)([i]) which is issued by the Chinese National Quality Intendance Quarantine Agency, Sanitation Office, National Environment Protection Agency on November 19th 2002 and. implemented on March 1st 2003, the order of the concentrations of formaldehyde is the underground mark, the office, the park, the hotel in turn, the formaldehyde's concentrations of the park and the hotel are close. But all of the analysis results have not exceeded the limit concentration. The concentrations of benzene in the surveyed underground space are not exceed the standards except the parks, the rate of superscale is 75%. The superscale rates of toluene are 7% in subway, 83% in the parks, 84% in the underground marks and 0% in the hotels and offices respectively. The superscale rates of xylene are 11% in the underground mark, 42% in the park and 0% in the hotel, subway and office respectively. It can be concluded that the air quality of underground hotels, offices, subway are better, the contamination of the underground marks and the parks are severity, the series compounds of benzene are the main contaminations in the parks.
引用
收藏
页码:957 / 965
页数:9
相关论文
共 50 条
  • [21] Indoor Air Quality Survey of Nail Salons in Boston
    Laura J. Goldin
    Liza Ansher
    Ariana Berlin
    Jenny Cheng
    Deena Kanopkin
    Anna Khazan
    Meda Kisivuli
    Molly Lortie
    Emily Bunker Peterson
    Laura Pohl
    Sam Porter
    Vivian Zeng
    Tiffany Skogstrom
    Matt A. Fragala
    Theodore A. Myatt
    James H. Stewart
    Joseph G. Allen
    Journal of Immigrant and Minority Health, 2014, 16 : 508 - 514
  • [22] Indoor Air Quality Survey of Nail Salons in Boston
    Goldin, Laura J.
    Ansher, Liza
    Berlin, Ariana
    Cheng, Jenny
    Kanopkin, Deena
    Khazan, Anna
    Kisivuli, Meda
    Lortie, Molly
    Peterson, Emily Bunker
    Pohl, Laura
    Porter, Sam
    Zeng, Vivian
    Skogstrom, Tiffany
    Fragala, Matt A.
    Myatt, Theodore A.
    Stewart, James H.
    Allen, Joseph G.
    JOURNAL OF IMMIGRANT AND MINORITY HEALTH, 2014, 16 (03) : 508 - 514
  • [23] INDOOR AIR-POLLUTION BY SMOKE CONSTITUENTS - A SURVEY
    TRIEBIG, G
    ZOBER, MA
    PREVENTIVE MEDICINE, 1984, 13 (06) : 570 - 581
  • [24] INDOOR AIR-POLLUTION VIA A SPACE HEATER
    ENGELBERG, AL
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1984, 251 (07): : 958 - 959
  • [25] Impact of kerosene space heaters on indoor air quality
    Hanoune, B.
    Carteret, M.
    CHEMOSPHERE, 2015, 134 : 581 - 587
  • [26] An Measurement and Analysis of Public Space Indoor Air Quality
    Liang Shuang
    Chen Jing
    Wang Yali
    ZhaoXiang
    Chen Jing
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [27] A review on characteristics and mitigation strategies of indoor air quality in underground subway stations
    Yang, Junbin
    Fan, Xianwang
    Zhang, Huan
    Zheng, Wandong
    Ye, Tianzhen
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 869
  • [28] Advances in research for underground buildings: Energy, thermal comfort and indoor air quality
    Yu, Jia
    Kang, Yanming
    Zhai, Zhiqiang
    ENERGY AND BUILDINGS, 2020, 215
  • [29] Investigation of Indoor Air Quality and Staff Satisfaction in Underground Buildings in Xi'an, China
    Zhang, Xin
    Fan, Yuesheng
    Yu, Wanqing
    Wang, Huan
    Zhao, Feilong
    Tao, Haitao
    Fu, Zeming
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2021, 30 (04): : 3365 - 3373
  • [30] Effect of platform screen doors on the indoor air environment of an underground subway station
    Han, Hwataik
    Lee, Jun-Yong
    Jang, Kyung-Jin
    INDOOR AND BUILT ENVIRONMENT, 2015, 24 (05) : 672 - 681