Survey on the indoor air of the underground space

被引:0
|
作者
Qu, GL [1 ]
Yue, LJ [1 ]
Min, YQ [1 ]
Ma, GH [1 ]
Li, FR [1 ]
机构
[1] Inst Chem Def, Beijing 102205, Peoples R China
关键词
the indoor air of the underground space; formaldehyde; benzene; toluene; xylene; volatile organic compounds;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The volatile organic compounds (VOCs) in different underground spaces were surveyed, the results showed that more than 60 kinds of VOCs were ubiquitous. On this basis, aiming at the underground marks, the hotels, the parks, the offices and the subway, the further quantitative analysis was processed. The quantitative analysis results indicated that organic compounds such as formaldehyde, benzene, toluene and xylene etc. were the major pollutants in the underground space. According to the limit concentration of formaldehyde, benzene, toluene and xylene in the Quality Standards of Indoor Air (GB/T18883-2002)([i]) which is issued by the Chinese National Quality Intendance Quarantine Agency, Sanitation Office, National Environment Protection Agency on November 19th 2002 and. implemented on March 1st 2003, the order of the concentrations of formaldehyde is the underground mark, the office, the park, the hotel in turn, the formaldehyde's concentrations of the park and the hotel are close. But all of the analysis results have not exceeded the limit concentration. The concentrations of benzene in the surveyed underground space are not exceed the standards except the parks, the rate of superscale is 75%. The superscale rates of toluene are 7% in subway, 83% in the parks, 84% in the underground marks and 0% in the hotels and offices respectively. The superscale rates of xylene are 11% in the underground mark, 42% in the park and 0% in the hotel, subway and office respectively. It can be concluded that the air quality of underground hotels, offices, subway are better, the contamination of the underground marks and the parks are severity, the series compounds of benzene are the main contaminations in the parks.
引用
收藏
页码:957 / 965
页数:9
相关论文
共 50 条
  • [1] Data-driven prediction model of indoor air quality in an underground space
    Kim, Min Han
    Kim, Yong Su
    Lim, JungJin
    Kim, Jeong Tai
    Sung, Su Whan
    Yoo, ChangKyoo
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2010, 27 (06) : 1675 - 1680
  • [2] Data-driven prediction model of indoor air quality in an underground space
    Min Han Kim
    Yong Su Kim
    JungJin Lim
    Jeong Tai Kim
    Su Whan Sung
    ChangKyoo Yoo
    Korean Journal of Chemical Engineering, 2010, 27 : 1675 - 1680
  • [3] Indoor air quality assessment in an underground parking facility
    El Fadel, M
    Alameddine, I
    Kazopoulo, M
    Hamdan, M
    Nasrallah, R
    INDOOR AND BUILT ENVIRONMENT, 2001, 10 (3-4) : 179 - 184
  • [4] Investigation of Indoor Air Quality in the Underground Shopping Mall
    Yang, Jia
    Wu, Xiangsheng
    Chan, K. T.
    Yang, Xiaofeng
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [5] Field study method for indoor air of linear underground facilities
    Lushin, Kirill
    Plyushchenko, Natalia
    Ananyev, Aleksey
    5TH INTERNATIONAL SCIENTIFIC CONFERENCE INTEGRATION, PARTNERSHIP AND INNOVATION IN CONSTRUCTION SCIENCE AND EDUCATION, 2016, 86
  • [6] A Hygienic Survey of the Environment of Underground Space and Buildings
    YUE LIN
    BiomedicalandEnvironmentalSciences, 1989, (03) : 282 - 286
  • [7] Automatic Parking Space Detection and Tracking for Underground and Indoor Environments
    Suhr, Jae Kyu
    Jung, Ho Gi
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (09) : 5687 - 5698
  • [8] Applied Research on the Decorative Materials in Indoor Underground Public Space
    Fan, Wei
    Liu, Wenjin
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 5099 - +
  • [9] Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station
    Yim, Bongbeen
    Lee, Kyusung
    Kim, Jooin
    Hong, Hyunsu
    Kim, Jangwon
    Jo, Kyung-Ho
    Jung, Eulgyu
    Kim, Inkyu
    An, Yeonsun
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2014, 30 (03) : 233 - 244
  • [10] A survey of indoor air quality in public facilities
    Kim, YS
    Roh, YM
    Hong, SC
    Lee, CM
    Jun, HJ
    Kim, JC
    Cho, JH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 833 - 836