Dual-mode detection and efficient annihilation of pathogenic bacteria based on the construction of a ratiometric electrochemiluminescent/electrochemical sensor

被引:10
作者
Shan, Xia [1 ,2 ]
Feng, Qiumei [1 ,3 ]
Yang, Jie [1 ]
Wang, Po [1 ,3 ]
机构
[1] Nanjing Univ, Sch Life Sci, State Key Lab Analyt Chem Life Sci, Nanjing 210023, Peoples R China
[2] Nantong Univ, Xinglin Coll, Nantong 226019, Peoples R China
[3] Jiangsu Normal Univ, Sch Chem & Mat Sci, Xuzhou 221116, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Staphylococcus aureu; Electrochemiluminescent/electrochemical sensor; Dual-mode detection; Two-step signal amplification; Antibacterial ability; GOLD NANOPARTICLES; NANOCLUSTERS;
D O I
10.1016/j.snb.2022.132633
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensitive, reliable, and selective detection of pathogenic bacteria is a key objective for the assessment of public health. Here, a ratiometric electrochemiluminescent/electrochemical (ECL/EC) sensor sensitized with a two-step signal amplification strategy was designed for the dual-mode detection of pathogenic bacteria. Target-induced releasing of multi-DNA strands, as the first-step amplification, transformed Staphylococcus aureus (S. aureus) into abundant intermediate DNA strands, which then hybridized with the block DNA (W). New splice sites were formed via hybridization of the releasing swing arm with EC indicator-labeled anchor DNA. With the introduction of nicking endonuclease, DNA walker was activated as the second-step amplification, yielding abundant single-stranded DNAs on the sensing interface. ECL emitter-labeled probe DNA was hybridized with the left DNAs, resulting in a significant increase in ECL/EC ratio value to achieve sensitive monitoring of S. aureus. Taking advantage of the two-step signal amplification strategy, this method exhibited a high sensitivity for S. aureus analysis with a low detection limit of 1 CFU/mL. Concurrently, this sensing strategy brought about satisfactory results for S. aureus assay when interfering bacterial strains and complex matrices appeared. Furthermore, aptamer encapsulated silver nanoclusters (aptamer-Ag NCs) exhibited striking bactericidal performance against S. aureus during the experiment, which opened a promising antifouling avenue to eliminate bacteria.
引用
收藏
页数:8
相关论文
共 41 条
[21]   DNA NANOTECHNOLOGY Self-assembly of genetically encoded DNA-protein hybrid nanoscale shapes [J].
Praetorius, Florian ;
Dietz, Hendrik .
SCIENCE, 2017, 355 (6331)
[22]   Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor [J].
Radi, AE ;
Sánchez, JLA ;
Baldrich, E ;
O'Sullivan, CK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (01) :117-124
[23]   Engineering of a Dual-Recognition Ratiometric Fluorescent Nanosensor with a Remarkably Large Stokes Shift for Accurate Tracking of Pathogenic Bacteria at the Single-Cell Level [J].
Shen, Yizhong ;
Wu, Tingting ;
Zhang, Yiyin ;
Ling, Na ;
Zheng, Libing ;
Zhang, Shao-Lin ;
Sun, Yidan ;
Wang, Xiaohong ;
Ye, Yingwang .
ANALYTICAL CHEMISTRY, 2020, 92 (19) :13396-13404
[24]   Ruthenium based antimicrobial theranostics - using nanoscopy to identify therapeutic targets and resistance mechanisms in Staphylococcus aureus [J].
Smitten, Kirsty L. ;
Fairbanks, Simon D. ;
Robertson, Craig C. ;
de la Serna, Jorge Bernardino ;
Foster, Simon J. ;
Thomas, James A. .
CHEMICAL SCIENCE, 2020, 11 (01) :70-79
[25]   Methods for the detection and identification of pathogenic bacteria: past, present, and future [J].
Varadi, Linda ;
Luo, Jia Lin ;
Hibbs, David E. ;
Perry, John D. ;
Anderson, Rosaleen J. ;
Orenga, Sylvain ;
Groundwater, Paul W. .
CHEMICAL SOCIETY REVIEWS, 2017, 46 (16) :4818-4832
[26]   Strongly emissive individual DNA-encapsulated Ag nanoclusters as single-molecule fluorophores [J].
Vosch, Tom ;
Antoku, Yasuko ;
Hsiang, Jung-Cheng ;
Richards, Chris I. ;
Gonzalez, Jose I. ;
Dickson, Robert M. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (31) :12616-12621
[27]   Ultrasensitive microfluidic immunosensor with stir bar enrichment for point-of-care test of Staphylococcus aureus in foods triggered by DNAzyme-assisted click reaction [J].
Wang, Jiaqi ;
Tan, Lei ;
Bi, Wenchao ;
Shen, Haoyu ;
Li, Dengfeng ;
Yu, Zhenzhong ;
Gan, Ning .
FOOD CHEMISTRY, 2022, 378
[28]   In Vivo High-resolution Ratiometric Fluorescence Imaging of Inflammation Using NIR-II Nanoprobes with 1550 nm Emission [J].
Wang, Shangfeng ;
Liu, Lu ;
Fan, Yong ;
El-Toni, Ahmed Mohamed ;
Alhoshan, Mansour Saleh ;
Li, Dandan ;
Zhang, Fan .
NANO LETTERS, 2019, 19 (04) :2418-2427
[29]   Comparative study of Pd@Pt nanozyme improved colorimetric N-ELISA for the paper-output portable detection of Staphylococcus aureus [J].
Wang, Xin ;
Zhang, Min ;
Pang, Xiaoxu ;
Huang, Kunlun ;
Yao, Zhiyi ;
Mei, Xiaohong ;
Cheng, Nan .
TALANTA, 2022, 247
[30]   DNA walker-mediated biosensor for target-triggered triple-mode detection of Vibrio parahaemolyticus [J].
Wei, Wenting ;
Lin, Han ;
Hao, Tingting ;
Wang, Sui ;
Hu, Yufang ;
Guo, Zhiyong ;
Luo, Xingyu .
BIOSENSORS & BIOELECTRONICS, 2021, 186