Determination and quantitation of sulfonylurea and urea herbicides in water samples using liquid chromatography with electrospray ionization mass spectrometric detection

被引:81
作者
Ayano, E
Kanazawa, H
Ando, M
Nishimura, T
机构
[1] Natl Inst Hlth Sci, Div Environm Chem, Setagaya Ku, Tokyo 1588501, Japan
[2] Kyoritsu Coll Pharmaceut Sci, Minato Ku, Tokyo 1058512, Japan
关键词
sulfonylurea herbicides; urea herbicides; LC-ESI-MS; SPE; water samples;
D O I
10.1016/j.aca.2003.11.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multianalyte method has been developed for the confirmation and quantitation of five sulfonylureas, bensulfuron-methyl, imazosulfuron, pyrazosulfuron-ethyl, flazasulfuron and halosulfuron-methyl, and for three ureas, siduron, dymron (daimuron) and diuron (DCMU) in water. Samples were extracted from water by off-line solid-phase extraction (SPE) with a polystyrene polymer cartridge (PS2), an ODS C-18-bonded silica cartridge (C 18) and an N-vinylpyrrolidone polymer cartridge (Oasis). Analyte determination and quantitation were performed by liquid chromatography with mass spectrometry (LC-MS). Extraction efficiency experiments demonstrated the ability of this method to extract sulfonylureas and ureas from water samples. Confirmatory analysis was carried out by LC-electrospray mass spectrometry (LC-ESI-MS) instrumentation equipped with a single-quadrupole mass filter. MS data acquisition was performed by a single or two-ion selected ion monitoring (SIM) program. It is required for confirmation that LC-MS retention times of the analytes are within 1% of the retention times of the standards, and that the molecular ion or characteristic fragment ion is present for each analyte. Fragment ions from distinctive structures must be obtained to identify and characterize specific herbicide molecules. These were obtained by controlled decomposition of sulfonylurea and urea adduct ions after suitably adjusting the electrical field in the desolvation chamber. The eight herbicides were also measured in fortified pure water (water purified by a milli-Q system), tap water and river water. Average recoveries of the eight analytes from water samples were in the range of 70-120% with relative standard deviations (R.S.D.s) of <20%. The limit of quantitation (LOQ) for each of the eight herbicides was between 10 and 100 ng l(-1). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 29 条
[1]   TRACE RESIDUE ANALYSIS OF THE HERBICIDE CHLORSULFURON IN SOIL BY GAS-CHROMATOGRAPHY ELECTRON-CAPTURE DETECTION [J].
AHMAD, I ;
CRAWFORD, G .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1990, 38 (01) :138-141
[2]   APPLICATION OF A TRIASULFURON ENZYME-IMMUNOASSAY TO THE ANALYSIS OF INCURRED RESIDUES IN SOIL AND WATER SAMPLES [J].
BRADY, JF ;
TURNER, J ;
SKINNER, DH .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (09) :2542-2547
[3]   Kinetics and hydrolysis mechanism of triasulfuron [J].
Braschi, I ;
Calamai, L ;
Cremonini, MA ;
Fusi, P ;
Gessa, C ;
Pantani, O ;
Pusino, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (11) :4495-4499
[4]   Degradation of thifensulfuron methyl in soil: Role of microbial carboxyesterase activity [J].
Brown, HM ;
Joshi, MM ;
Van, AT ;
Carski, TH ;
Dulka, JJ ;
Patrick, MC ;
Reiser, RW ;
Livingston, RS ;
Doughty, J .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (03) :955-961
[5]   Trace analysis of sulfonylurea herbicides in water: Extraction and purification by a Carbograph 4 cartridge, followed by liquid chromatography with UV detection, and confirmatory analysis by an electrospray mass detector [J].
DiCorcia, A ;
Crescenzi, C ;
Samperi, R ;
Scappaticcio, L .
ANALYTICAL CHEMISTRY, 1997, 69 (14) :2819-2826
[6]   DETERMINATION OF THE SULFONYLUREA HERBICIDES CHLORSULFURON AND METSULFURON-METHYL IN SOIL, WATER AND PLANT-MATERIAL BY GAS-CHROMATOGRAPHY OF THEIR PENTAFLUOROBENZYL DERIVATIVES [J].
COTTERILL, EG .
PESTICIDE SCIENCE, 1992, 34 (03) :291-296
[7]   IDENTIFICATION OF MICROBIAL AND RAT METABOLITES OF TRIFLUSULFURON METHYL, A NEW SUGAR-BEET HERBICIDE [J].
DIETRICH, RF ;
REISER, RW ;
STIEGLITZ, B .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (02) :531-536
[8]   DETECTION AND QUANTITATION OF SULFONYLUREA HERBICIDES IN SOIL AT THE PPB LEVEL BY CAPILLARY ELECTROPHORESIS [J].
DINELLI, G ;
VICARI, A ;
BRANDOLINI, V .
JOURNAL OF CHROMATOGRAPHY A, 1995, 700 (1-2) :201-207
[9]   USE OF CAPILLARY ELECTROPHORESIS FOR DETECTION OF METSULFURON AND CHLORSULFURON IN TAP WATER [J].
DINELLI, G ;
VICARI, A ;
CATIZONE, P .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (05) :742-746
[10]   Hydrolytic dissipation of four sulfonylurea herbicides [J].
Dinelli, G ;
Vicari, A ;
Bonetti, A ;
Catizone, P .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (05) :1940-1945