Technical principles of dual source CT

被引:367
作者
Petersilka, Martin [1 ]
Bruder, Herbert [1 ]
Krauss, Bernhard [1 ]
Stierstorfer, Karl [1 ]
Flohr, Thomas G. [1 ,2 ]
机构
[1] Siemens Hlth Care, Forchheim, Germany
[2] Univ Tubingen, Dept Diagnost Radiol, Tubingen, Germany
关键词
Computed tomography; Dual source; Cardiac CT; Thoracic CT; Dual energy CT; Low dose;
D O I
10.1016/j.ejrad.2008.08.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
During the past years, multi-detector row CT (MDCT) has evolved into clinical practice with a rapid increase of the number of detector slices. Today's 64 slice CT systems allow whole-body examinations with sub-millimeter resolution in short scan times. As an alternative to adding even more detector slices, we describe the system concept and design of a CT scanner with two X-ray tubes and two detectors (mounted on a CT gantry with a mechanical offset of 90 degrees) that has the potential to overcome limitations of conventional MDCT systems, such as temporal resolution for cardiac imaging. A dual source CT (DSCT) scanner provides temporal resolution equivalent to a quarter of the gantry rotation time, independent of the patient's heart rate (83 ms at 0.33 s rotation time). In addition to the benefits for cardiac scanning, it allows to go beyond conventional CT imaging by obtaining dual energy information if the two tubes are operated at different voltages. Furthermore, we discuss how both acquisition systems can be used to add the power reserve of two X-ray tubes for long scan ranges and obese patients. Finally, future advances of DSCT are highlighted. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:362 / 368
页数:7
相关论文
共 26 条
  • [1] Bruder H, 2006, P SOC PHOTO-OPT INS, V6142, P1
  • [2] Coronary arterial calcium screening: Ready for prime time
    Flamm, SD
    [J]. RADIOLOGY, 1998, 208 (03) : 571 - 572
  • [3] Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    Flohr, T
    Ohnesorge, B
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 907 - 923
  • [4] Performance evaluation of a 64-slice CT system with z-flying focal spot
    Flohr, T
    Stierstorfer, K
    Raupach, R
    Ulzheimer, S
    Bruder, H
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12): : 1803 - 1810
  • [5] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [6] Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot
    Flohr, TG
    Stierstorfer, K
    Ulzheimer, S
    Bruder, H
    Primak, AN
    McCollough, CH
    [J]. MEDICAL PHYSICS, 2005, 32 (08) : 2536 - 2547
  • [7] Xenon ventilation CT using a dual-source dual-energy technique: dynamic ventilation abnormality in a child with bronchial atresia
    Goo, Hyun Woo
    Chae, Eun Jin
    Seo, Joon Beom
    Hong, Soo-Jong
    [J]. PEDIATRIC RADIOLOGY, 2008, 38 (10) : 1113 - 1116
  • [8] Graser A, EUR RADIOL IN PRESS
  • [9] Graser A, RADIOLOGY IN PRESS
  • [10] Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience
    Graser, Anno
    Johnson, Thorsten R. C.
    Bader, Markus
    Staehler, Michael
    Haseke, Nicolas
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Stief, Christian G.
    Becker, Christoph R.
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (02) : 112 - 119