Monitoring biomolecule concentrations in tissue using a wearable droplet microfluidic-based sensor

被引:121
作者
Nightingale, Adrian M. [1 ]
Leong, Chi Leng [1 ,2 ]
Burnish, Rachel A. [3 ]
Hassan, Sammer-ul [1 ]
Zhang, Yu [1 ]
Clough, Geraldine F. [4 ]
Boutelle, Martyn G. [2 ]
Voegeli, David [5 ,6 ]
Niu, Xize [1 ]
机构
[1] Univ Southampton, Fac Engn & Phys Sci, Southampton SO17 1BJ, Hants, England
[2] Imperial Coll London, Dept Bioengn, South Kensington, London SW7 2AZ, England
[3] Univ Hosp Southampton NHS Fdn Trust, Crit Care Anaesthesia & Perioperat Med Res Unit, Tremona Rd, Southampton SO16 6YD, Hants, England
[4] Univ Southampton, Fac Med, Southampton SO17 1BJ, Hants, England
[5] Univ Southampton, Fac Environm & Life Sci, Southampton SO17 1BJ, Hants, England
[6] Univ Winchester, Dept Sport Exercise & Hlth, Winchester SO22 4NR, Hants, England
基金
英国工程与自然科学研究理事会;
关键词
MICRODIALYSIS PROBE; SEGMENTED FLOW; GLUCOSE; BIOSENSORS; INJECTION; OXIDASE; DEVICES; SYSTEM; BLOOD; CHIP;
D O I
10.1038/s41467-019-10401-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Knowing how biomarker levels vary within biological fluids over time can produce valuable insight into tissue physiology and pathology, and could inform personalised clinical treatment. We describe here a wearable sensor for monitoring biomolecule levels that combines continuous fluid sampling with in situ analysis using wet-chemical assays (with the specific assay interchangeable depending on the target biomolecule). The microfluidic device employs a droplet flow regime to maximise the temporal response of the device, using a screw-driven push-pull peristaltic micropump to robustly produce nanolitre-sized droplets. The fully integrated sensor is contained within a small (palm-sized) footprint, is fully autonomous, and features high measurement frequency (a measurement every few seconds) meaning deviations from steady-state levels are quickly detected. We demonstrate how the sensor can track perturbed glucose and lactate levels in dermal tissue with results in close agreement with standard off-line analysis and consistent with changes in peripheral blood levels.
引用
收藏
页数:12
相关论文
共 74 条
[61]   How Minimally Invasive is Microdialysis Sampling? A Cautionary Note for Cytokine Collection in Human Skin and other Clinical Studies [J].
Stenken, Julie A. ;
Church, Martin K. ;
Gill, Carolyn A. ;
Clough, Geraldine F. .
AAPS JOURNAL, 2010, 12 (01) :73-78
[62]   Design of microfluidic channel geometries for the control of droplet volume, chemical concentration, and sorting [J].
Tan, YC ;
Fisher, JS ;
Lee, AI ;
Cristini, V ;
Lee, AP .
LAB ON A CHIP, 2004, 4 (04) :292-298
[63]   A low cost and high throughput magnetic bead-based immuno-agglutination assay in confined droplets [J].
Teste, Bruno ;
Ali-Cherif, Anais ;
Viovy, Jean Louis ;
Malaquin, Laurent .
LAB ON A CHIP, 2013, 13 (12) :2344-2349
[65]   Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry [J].
Tüdos, AJ ;
Besselink, GAJ ;
Schasfoort, RBM .
LAB ON A CHIP, 2001, 1 (02) :83-95
[66]   Dripping to jetting transitions in coflowing liquid streams [J].
Utada, Andrew S. ;
Fernandez-Nieves, Alberto ;
Stone, Howard A. ;
Weitz, David A. .
PHYSICAL REVIEW LETTERS, 2007, 99 (09)
[67]   Improved temporal resolution for in vivo microdialysis by using segmented flow [J].
Wang, Meng ;
Roman, Gregory T. ;
Schultz, Kristin ;
Jennings, Colin ;
Kennedy, Robert T. .
ANALYTICAL CHEMISTRY, 2008, 80 (14) :5607-5615
[68]   Microfluidic Chip for High Efficiency Electrophoretic Analysis of Segmented Flow from a Microdialysis Probe and in Vivo Chemical Monitoring [J].
Wang, Meng ;
Roman, Gregory T. ;
Perry, Maura L. ;
Kennedy, Robert T. .
ANALYTICAL CHEMISTRY, 2009, 81 (21) :9072-9078
[69]   Biosensors for real-time in vivo measurements [J].
Wilson, GS ;
Gifford, R .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2388-2403
[70]   Characterization of implantable biosensor membrane biofouling [J].
Wisniewski, N ;
Moussy, F ;
Reichert, WM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7) :611-621