Optimisation of reactive power compensation of HVAC cable in off-shore wind power plant

被引:13
作者
Zhu Guiping [1 ]
Dui Xiaowei [1 ]
Zhang Chen [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
关键词
HVDC;
D O I
10.1049/iet-rpg.2014.0375
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
High voltage AC (HVAC) transmission system is preferred to be used in off-shore wind power plant which is located within 40km from the seashore. Capacitance of HVAC cables is naturally higher than that of overhead lines, and it should be properly compensated. P model of three-core XLPE cable which is widely used in off-shore wind power plant was applied in the paper. Based on this model, impacts of reactive power compensation on HVAC transmission system, including capacity and location of compensation equipment, were analyzed and simulated then. Research showed that inductive compensation at off-shore side of the cable is more effective to decrease power loss along the cable and increase its transmission capacity than that at onshore side, while the latter is more appropriate to improve the power factor at onshore access point of the wind power plant to grid. Compensation capacity was optimized to realize the best economy with designated certain parameters of HVAC system by Sequential Quadratic Programming (SQP) method. Finally by SQP costs of 35kV and 220kV HVAC transmission system were compared, critical distance and transmission capacity of these two systems adoption were found. These results can be a reference of HVAC transmission system design of off-shore wind power plant.
引用
收藏
页码:857 / 863
页数:7
相关论文
共 7 条
[1]  
[Anonymous], 1926, Bell Syst Tech J, DOI DOI 10.1002/J.1538-7305.1926.TB00122.X
[2]  
Benato R., 2012, PERFORMANCE PLANNING
[3]   Comparative Evaluation of the HVDC and HVAC Links Integrated in a Large Offshore Wind Farm-An Actual Case Study in Taiwan [J].
Chou, Chih-Ju ;
Wu, Yuan-Kang ;
Han, Gia-Yo ;
Lee, Ching-Yin .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (05) :1639-1648
[4]  
Lin L., 2012, ENERGY TECHNOL EC, V24, P66
[5]   Loss evaluation of HVAC and HVDC transmission solutions for large offshore wind farms [J].
Negra, N. Barberis ;
Todorovic, J. ;
Ackermann, T. .
ELECTRIC POWER SYSTEMS RESEARCH, 2006, 76 (11) :916-927
[6]  
Xiaowei D., 2014, ADV MAT RES, V986-987, P433, DOI [10.4028/www.scientific.net/AMR.986-987.433, DOI 10.4028/WWW.SCIENTIFIC.NET/AMR.986-987.433]
[7]  
Yongfu S., 2005, COAST ENG, V24, P48