Quantitative assessment of regional cerebral blood flow by dynamic susceptibility contrast-enhanced MRI, without the need for arterial blood signals

被引:7
作者
Enmi, Jun-ichiro [1 ]
Kudomi, Nobuyuki [2 ]
Hayashi, Takuya [3 ]
Yamamoto, Akihide [1 ]
Iguchi, Satoshi [1 ]
Moriguchi, Tetsuaki [1 ]
Hori, Yuki [1 ]
Koshino, Kazuhiro [1 ]
Zeniya, Tsutomu [1 ]
Shah, Nadim Jon [4 ,5 ]
Yamada, Naoaki [6 ]
Iida, Hidehiro [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr, Res Inst, Dept Invest Radiol, Suita, Osaka 5658565, Japan
[2] Kagawa Univ, Fac Med, Dept Med Phys, Miki, Kagawa 7610793, Japan
[3] RIKEN, Ctr Mol Imaging Sci, Funct Probe Res Lab, Chuo Ku, Kobe, Hyogo 6500047, Japan
[4] Forschungszentrum Julich, Med Imaging Phys, Inst Neurosci & Med 4, D-52425 Julich, Germany
[5] Rhein Westfal TH Aachen, JARA, Fac Med, Dept Neurol, D-52074 Aachen, Germany
[6] Natl Cerebral & Cardiovasc Ctr, Dept Radiol, Suita, Osaka 5658565, Japan
关键词
POSITRON-EMISSION-TOMOGRAPHY; INPUT FUNCTION ESTIMATION; MONTE-CARLO METHOD; PERFUSION MRI; MAGNETIC-RESONANCE; BOLUS-TRACKING; METABOLIC-RATE; QUANTIFICATION; DECONVOLUTION; SYSTEM;
D O I
10.1088/0031-9155/57/23/7873
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI), an arterial input function (AIF) is usually obtained from a time-concentration curve (TCC) of the cerebral artery. This study was aimed at developing an alternative technique for reconstructing AIF from TCCs of multiple brain regions. AIF was formulated by a multi-exponential function using four parameters, and the parameters were determined so that the AIF curves convolved with a model of tissue response reproduced the measured TCCs for 20 regions. Systematic simulations were performed to evaluate the effects of possible error sources. DSC-MRI and positron emission tomography (PET) studies were performed on 14 patients with major cerebral artery occlusion. Cerebral blood flow (CBF) images were calculated from DSC-MRI data, using our novel method alongside conventional AIF estimations, and compared with those from O-15-PET. Simulations showed that the calculated CBF values were sensitive to variations in the assumptions regarding cerebral blood volume. Nevertheless, AIFs were reasonably reconstructed for all patients. The difference in CBF values between DSC-MRI and PET was -2.2 +/- 7.4 ml/100 g/min (r = 0.55, p < 0.01) for our method, versus -0.2 +/- 8.2 ml/100 g/min (r = 0.47, p = 0.01) for the conventional method. The difference in the ratio of affected to unaffected hemispheres between DSC-MRI and PET was 0.07 +/- 0.09 (r = 0.82, p < 0.01) for our method, versus 0.07 +/- 0.09 (r = 0.83, p < 0.01) for the conventional method. The contrasts in CBF images from our method were the same as those from the conventional method. These findings suggest the feasibility of assessing CBF without arterial blood signals.
引用
收藏
页码:7873 / 7892
页数:20
相关论文
共 48 条
[41]  
Vonken EPA, 1999, MAGN RESON MED, V41, P343, DOI 10.1002/(SICI)1522-2594(199902)41:2<343::AID-MRM19>3.0.CO
[42]  
2-T
[43]   Improved deconvolution of perfusion MRI data in the presence of bolus delay and dispersion [J].
Willats, Lisa ;
Connelly, Alan ;
Calamante, Fernando .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) :146-156
[44]   Effects of tracer arrival time on flow estimates in MR perfusion-weighted imaging [J].
Wu, O ;
Ostergaard, L ;
Koroshetz, WJ ;
Schwamm, LH ;
O'Donnell, J ;
Schaefer, PW ;
Rosen, BR ;
Weisskoff, RM ;
Sorensen, AG .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) :856-864
[45]   Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix [J].
Wu, O ;
Ostergaard, L ;
Weisskoff, RM ;
Benner, T ;
Rosen, BR ;
Sorensen, AG .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :164-174
[46]   REDUCTION IN REGIONAL CEREBRAL METABOLIC-RATE OF OXYGEN DURING HUMAN AGING [J].
YAMAGUCHI, T ;
KANNO, I ;
UEMURA, K ;
SHISHIDO, F ;
INUGAMI, A ;
OGAWA, T ;
MURAKAMI, M ;
SUZUKI, K .
STROKE, 1986, 17 (06) :1220-1228
[47]   Estimating the arterial input function using two reference tissues in dynamic contrast-enhanced MRI studies: Fundamental concepts and simulations [J].
Yang, C ;
Karczmar, GS ;
Medved, M ;
Stadler, WM .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) :1110-1117
[48]   Multiple reference tissue method for contrast agent arterial input function estimation [J].
Yang, Cheng ;
Karczmar, Gregory S. ;
Medved, Milica ;
Stadler, Walter M. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) :1266-1275