Recipient corneal thickness and visual outcome after Descemet's stripping automated endothelial keratoplasty

被引:14
作者
Ivarsen, Anders [1 ]
Hjortdal, Jesper [1 ]
机构
[1] Aarhus Univ Hosp, Dept Ophthalmol, DK-8000 Aarhus C, Denmark
关键词
GRAFT THICKNESS; GLYCOSAMINOGLYCANS; ACUITY; POLYSACCHARIDES; TRANSPARENCY; DYSTROPHY; MEMBRANE; EDEMA;
D O I
10.1136/bjophthalmol-2013-304042
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Descemet's stripping automated endothelial keratoplasty (DSAEK) is widely performed for endothelial failure. Unfortunately, the visual outcome is often mediocre and the underlying cause unclear. This study examines whether corneal light scatter and recipient corneal thickness (RCT) influence the visual outcome after DSAEK. Methods Patients attending clinical control after DSAEK were recruited during 4 months. In total, 125 eyes from 93 patients were enrolled. Postoperative time averaged 20 +/- 13 months. Data from previous controls were also reviewed. Examinations included corrected distance visual acuity (CDVA), Pentacam and anterior-segment OCT. From OCT and Pentacam data, RCT and lamellar graft thickness (LGT) were determined. Corneal densitometry was estimated from Pentacam images. Results 6 months after DSAEK, RCT measured 482 +/- 27 mu m. After 3 years, RCT was significantly higher, measuring 505 +/- 23 mu m. Pentacam and OCT showed similar variations in RCT. Also, in paired observations, from patients with previous controls, RCT increased significantly. Concurrently, corneal densitometry decreased and CDVA improved from 0.30 +/- 0.13 logMAR by 6 months to 0.17 +/- 0.08 logMAR by 4 years. No changes in LGT were observed. Changes in RCT, densitometry and CDVA were significantly correlated. Conclusions The study suggests that changes in RCT and corneal densitometry are important for the visual outcome after DSAEK.
引用
收藏
页码:30 / 34
页数:5
相关论文
共 50 条
[41]   Textural interface opacity after Descemet-stripping automated endothelial keratoplasty [J].
Kim, Keunsoo ;
Alder, Brian ;
Vora, Gargi K. ;
Carlson, Alan N. ;
Afshari, Natalie A. ;
Kuo, Anthony N. ;
Kim, Terry .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (09) :1514-1520
[42]   Refractive Change After Descemet Stripping Automated Endothelial Keratoplasty Surgery and Its Correlation With Graft Thickness and Diameter [J].
Jun, Bokkwan ;
Kuo, Anthony N. ;
Afshari, Natalie A. ;
Carlson, Alan N. ;
Kim, Terry .
CORNEA, 2009, 28 (01) :19-23
[43]   Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis [J].
Sela, Tal Corina ;
Iflah, Moti ;
Muhsen, Khitam ;
Zahavi, Alon .
BMJ OPEN OPHTHALMOLOGY, 2023, 8 (01)
[44]   Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty) [J].
Wong, Melissa H. Y. ;
Chew, Annabel ;
Htoon, Hla M. ;
Lee, Beng H. ;
Cheng, Jun ;
Liu, Jiang ;
Tan, Donald T. ;
Mehta, Jodhbir S. .
BMC MEDICAL IMAGING, 2012, 12
[45]   Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty) [J].
Melissa HY Wong ;
Annabel Chew ;
Hla M Htoon ;
Beng H Lee ;
Jun Cheng ;
Jiang Liu ;
Donald T Tan ;
Jodhbir S Mehta .
BMC Medical Imaging, 12
[46]   Descemet Stripping Endothelial Keratoplasty-Rapid Recovery of Visual Acuity [J].
Maier, Philip ;
Reinhard, Thomas ;
Cursiefen, Claus .
DEUTSCHES ARZTEBLATT INTERNATIONAL, 2013, 110 (21) :365-U9
[47]   Histopathologic Examination of Failed Grafts in Descemet's Stripping with Automated Endothelial Keratoplasty [J].
Suh, Leejee H. ;
Dawson, Daniel G. ;
Mutapcic, Lejla ;
Rosenfeld, Steven I. ;
Culbertson, William W. ;
Yoo, Sonia H. ;
O'Brien, Terrence P. ;
Dubovy, Sander R. .
OPHTHALMOLOGY, 2009, 116 (04) :603-608
[48]   Donor lamella thickness after ultrathin Descemet stripping automated endothelial keratoplasty and its relation to postoperative visual acuity and pre-operative lamella measures [J].
van Rooij, Jeroen ;
Engel, Angela ;
Steijger-Vermaat, Petra ;
Molenaar, Annemieke ;
Vigueras-Guillen, Juan Pedro ;
Wubbels, Rene J. .
BMC OPHTHALMOLOGY, 2023, 23 (01)
[49]   Descemet Stripping Automated Endothelial Keratoplasty Performed by Cornea Fellows [J].
Hashemi, Hassan ;
Asghari, Hossein ;
Amanzadeh, Kazem ;
Behrooz, Mahmood Jabarvand ;
Beheshtnejad, Amirhooshang ;
Mohammadpour, Mehrdad .
CORNEA, 2012, 31 (09) :974-977
[50]   Clinicopathologic Findings in Failed Descemet Stripping Automated Endothelial Keratoplasty [J].
Zhang, Qing ;
Randleman, Bradley ;
Stulting, Doyle ;
Lee, W. Barry ;
Stone, Donald U. ;
Kozarsky, Alan M. ;
Grossniklaus, Hans E. .
ARCHIVES OF OPHTHALMOLOGY, 2010, 128 (08) :973-980