Spectrally resolved fluorescence lifetime and FRET measurements

被引:0
|
作者
Kelbauskas, Laimonas [1 ]
Dietrich, Sascha [2 ]
Hoffmann, Birgit [2 ]
Zimmer, Thomas [2 ]
Benndorf, Klaus [2 ]
Becker, Wolfgang [3 ]
Bergmann, Axel [3 ]
Kloecker, Nikolaj [4 ]
Biskup, Christoph [2 ]
机构
[1] Arizona State Univ, 1001 S McAllister Ave, Tempe, AZ 85287 USA
[2] Univ Jena, Inst Physiol 2, D-07740 Jena, Germany
[3] Becker & Hickl GmbH, D-12277 Berlin, Germany
[4] Univ Freiburg, Inst Physiol 2, D-79104 Freiburg, Germany
关键词
multi-wavelength fluorescence lifetime imaging (mwFLIM); Forster resonance energy transfer (FRET); time-correlated-single-photon-counting (TCSPC); streak camera;
D O I
10.1117/12.645809
中图分类号
TH742 [显微镜];
学科分类号
摘要
We present two different approaches that allow multi-wavelength fluorescence lifetime measurements in the time domain in conjunction with a laser scanning microscope and a pulsed excitation source. One technique is based on a streak camera system, the other technique is based on a time-correlated-single-photon-counting (TCSPC) approach. The complete setup consists of a laser scanning microscope (LSM-5 10, Zeiss), a polychromator (250is, Chromex), a streak camera (C5680 with M5677 sweep unit, Hamamatsu Photonics) or a 16-channel TCSPC detector head (PML-16, Becker & Hickl) connected to a TCSPC imaging module (SPC-730/SPC-830, Becker & Hickl). With these techniques it is possible to acquire fluorescence decays in several wavelength regions simultaneously. The fluorescence emitted by the sample can be recorded in a single measurement. No filters have to be used to separate the contributions of different fluorophores to the overall fluorescence signal. When applied to Forster resonance energy transfer (FRET) measurements, the technique allows to separate the decay components of the donor and acceptor fluorescence. In this way, it is possible to reliably determine FRET efficiencies between acceptor and donor fluorophores in given subcellular structures.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Fluorescence lifetime-resolved imaging microscopy: A general description of lifetime-resolved imaging measurements
    Clegg, RM
    Schneider, PC
    FLUORESCENCE MICROSCOPY AND FLUORESCENT PROBES, 1996, : 15 - 33
  • [22] Wavelength-resolved measurements of fluorescence lifetime of indocyanine green
    Gerega, Anna
    Zolek, Norbert
    Soltysinski, Tomasz
    Milej, Daniel
    Sawosz, Piotr
    Toczylowska, Beata
    Liebert, Adam
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (06)
  • [23] Blind unmixing of spectrally resolved lifetime images
    Fereidouni, Farzad
    Blab, Gerhard A.
    Gerritsen, Hans C.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (08)
  • [24] Investigation of NAD(P)H Fluorescence Decay in Living Cardiomyocytes with Spectrally-resolved Fluorescence Lifetime Spectroscopy
    ANEBA Swida
    CHORVAT Jr.Dusan
    BASSIEN-Capsa Valerie
    CHORVATOVA Alzbeta
    Chinese Journal of Biomedical Engineering, 2009, 18 (03) : 107 - 128
  • [25] Spectrally Resolved Fiber Photometry for In Vivo Multi-Color Fluorescence Measurements
    Zhou, Jingheng
    Yeh, Alan
    Meng, Chengbo
    Papaneri, Amy B.
    Peddada, Teja
    Kobzar, Nicholas P.
    Cui, Guohong
    CURRENT PROTOCOLS, 2022, 2 (11):
  • [26] Optimized Protocol of a Frequency Domain Fluorescence Lifetime Imaging Microscope for FRET Measurements
    Leray, Aymeric
    Riquet, Franck B.
    Richard, Elodie
    Spriet, Corentin
    Trinel, Dave
    Heliot, Laurent
    MICROSCOPY RESEARCH AND TECHNIQUE, 2009, 72 (05) : 371 - 379
  • [27] Spectrally resolved multidepth fluorescence imaging
    Luo, Yuan
    Zervantonakis, Ioannis K.
    Oh, Se Baek
    Kamm, Roger D.
    Barbastathis, George
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (09)
  • [28] Spectrally resolved measurements of reciprocity failure
    Heieck, J
    JOURNAL OF INFORMATION RECORDING, 1996, 23 (03): : 233 - 248
  • [29] Phase-resolved Fluorometer for Fluorescence Lifetime Measurements in the Human Eye
    Sridhar, Asnika
    Babu, D. R. Ramesh
    Pandya, Kaveet
    Kompella, Uday B.
    Srinivas, S. P.
    MATERIALS TODAY-PROCEEDINGS, 2019, 10 : 16 - 19
  • [30] LIFETIME AND TIME-RESOLVED FLUORESCENCE MEASUREMENTS WITH ACO SYNCHROTRON RADIATION
    LINDQVIST, L
    LOPEZDEL.R
    MARTIN, MM
    TRAMER, A
    OPTICS COMMUNICATIONS, 1974, 10 (03) : 283 - 287