Local cryostimulation acutely preserves maximum isometric handgrip strength following fatigue in young women

被引:6
作者
De Nardi, Massimo [1 ]
Silvani, Sara [2 ]
Ruggeri, Piero [1 ]
Luzi, Livio [2 ,3 ]
La Torre, Antonio [2 ,4 ]
Codella, Roberto [2 ,3 ]
机构
[1] Univ Genoa, Dept Expt Med, Genoa, Italy
[2] Univ Milan, Dept Biomed Sci Hlth, Via F Lli Cervi 93, I-20090 Milan, Italy
[3] IRCCS Policlin San Donato, Metab Res Ctr, Endocrinol & Metab, San Donato Milanese, Italy
[4] IRCCS Ist Ortoped Galeazzi, Milan, Italy
关键词
Cryostimulation; Local cryotherapy; Handgrip strength; Recovery; Maximal isometric force; WHOLE-BODY CRYOTHERAPY; GRIP STRENGTH; JAMAR DYNAMOMETER; ELBOW POSITION; PERFORMANCE; THERAPY;
D O I
10.1016/j.cryobiol.2019.03.002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Several types of cryostimulation have been recently proposed to rapidly lower skin temperature therefore gaining a possible neuro/muscular recovery after strenuous exercise or, more generally, in sports. Local cryostimulation may be a viable and relatively portable tool to obtain physiological benefits in previously-efforted muscular districts. However, cohesive and standardized cryo-exposure protocols are lacking as well as the righteous procedure to efficaciously combine duration, treatments and temperature in relation to desirable effects on muscular strength. In this randomized-controlled study, fifty young women were tested for maximum isometric handgrip strength, before and after exhausting contractions. Following the fatiguing protocol, the intervention group (cryo, n = 25, 24.7 +/- 2.5 years, BMI 21.7 +/- 1.8 kg/m(2)) underwent a 6-min local cryostimulation ( -160 degrees C) on the extensor-flexor muscles of the dominant arm, while control-matched peers sat rested in a thermo-neutral room (22 +/- 0.5 degrees C). Handgrip tests were repeated at baseline (TO), after cryostimulation (T1), and 15 min after T1 (T2). Throughout the protocol, the AUC of the strength performance was significantly higher in the cryo- compared to control group (P = 0.006). In particular, following fatigue and cryostimulation, the cryo group preserved higher strength at T1 with respect to controls (26.8 +/- 2.8 vs 23.9 +/- 2.8 kg, Bonferroni's post-hoc, P < 0.01). Likewise, ventral and dorsal temperature, recorded with a thermal camera, were lower in cryo- than control group (P < 0.0001). In conclusion, a brief session of local cryostimulation may acutely preserve maximal isometric force in young women following a fatiguing protocol. These findings may have implications in orchestrating strategies of district muscular recovery.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 49 条
  • [1] Altan A., 2018, P 2018 6 INT C CONTR, P1, DOI [DOI 10.1109/CEIT.2018.8751829, 10.1109/CEIT.2018.8751829]
  • [2] Aparicio VA, 2010, CLIN EXP RHEUMATOL, V28, pS78
  • [3] BAECKE JAH, 1982, AM J CLIN NUTR, V36, P936
  • [4] Bansode DG, 2014, INT J PHARMA RES HLT, V2, P316
  • [5] Barut C., 2008, ANATOMY, V2, P55, DOI [10.2399/ana.08.055, DOI 10.2399/ANA.08.055]
  • [6] GRIP STRENGTH TESTING USING THE BTE WORK SIMULATOR AND THE JAMAR DYNAMOMETER - A COMPARATIVE-STUDY
    BEATON, DE
    ODRISCOLL, SW
    RICHARDS, RR
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (02): : 293 - 298
  • [7] Muscle strength: clinical and prognostic value of hand-grip dynamometry
    Bohannon, Richard W.
    [J]. CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2015, 18 (05) : 465 - 470
  • [8] Reference values for adult grip strength measured with a Jamar dynamometer: a descriptive meta-analysis
    Bohannon, RW
    Peolsson, A
    Massy-Westropp, N
    Desrosiers, J
    Bear-Lehman, JB
    [J]. PHYSIOTHERAPY, 2006, 92 (01) : 11 - 15
  • [9] Whole- and partial-body cryostimulation/cryotherapy: Current technologies and practical applications
    Bouzigon, Romain
    Grappe, Frederic
    Ravier, Gilles
    Dugue, Benoit
    [J]. JOURNAL OF THERMAL BIOLOGY, 2016, 61 : 67 - 81
  • [10] Cappaert TA, 1999, J STRENGTH COND RES, V13, P412