A novel anthropomorphic flow phantom for the quantitative evaluation of prostate DCE-MRI acquisition techniques

被引:10
作者
Knight, Silvin P. [1 ]
Browne, Jacinta E. [2 ,3 ]
Meaney, James F. [1 ]
Smith, David S. [4 ]
Fagan, Andrew J. [1 ]
机构
[1] Trinity Coll Univ Dublin, St Jamess Hospital, Natl Ctr Adv Med Imaging CAMI, Sch Med, Dublin, Ireland
[2] Dublin Inst Technol, Sch Phys, FOCAS, Dublin, Ireland
[3] Dublin Inst Technol, Med Ultrasound Phys & Technol Grp, Ctr Ind Engn Opt, FOCAS, Dublin, Ireland
[4] Vanderbilt Univ, Inst Imaging Sci, Dept Radiol & Radiol Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
关键词
dynamic contrast-enhanced MRI; anthropomorphic phantom; quantitative imaging; prostate cancer; CONTRAST-ENHANCED MRI; CANCER; ANGIOGENESIS; PERMEABILITY; TRACER; AGGRESSIVENESS; PARAMETERS; PERFUSION; BRAIN;
D O I
10.1088/0031-9155/61/20/7466
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel anthropomorphic flow phantom device has been developed, which can be used for quantitatively assessing the ability of magnetic resonance imaging (MRI) scanners to accurately measure signal/concentration time-intensity curves (CTCs) associated with dynamic contrast-enhanced (DCE) MRI. Modelling of the complex pharmacokinetics of contrast agents as they perfuse through the tumour capillary network has shown great promise for cancer diagnosis and therapy monitoring. However, clinical adoption has been hindered by methodological problems, resulting in a lack of consensus regarding the most appropriate acquisition and modelling methodology to use and a consequent wide discrepancy in published data. A heretofore overlooked source of such discrepancy may arise from measurement errors of tumour CTCs deriving from the imaging pulse sequence itself, while the effects on the fidelity of CTC measurement of using rapidly-accelerated sequences such as parallel imaging and compressed sensing remain unknown. The present work aimed to investigate these features by developing a test device in which 'ground truth' CTCs were generated and presented to the MRI scanner for measurement, thereby allowing for an assessment of the DCE-MRI protocol to accurately measure this curve shape. The device comprised a four-pump flow system wherein CTCs derived from prior patient prostate data were produced in measurement chambers placed within the imaged volume. The ground truth was determined as the mean of repeat measurements using an MRI-independent, custom-built optical imaging system. In DCE-MRI experiments, significant discrepancies between the ground truth and measured CTCs were found for both tumorous and healthy tissue-mimicking curve shapes. Pharmacokinetic modelling revealed errors in measured K-trans, v(e) and k(ep) values of up to 42%, 31%, and 50% respectively, following a simple variation of the parallel imaging factor and number of signal averages in the acquisition protocol. The device allows for the quantitative assessment and standardisation of DCE-MRI protocols (both existing and emerging).
引用
收藏
页码:7466 / 7483
页数:18
相关论文
共 36 条
[1]   Reproducibility and Correlation Between Quantitative and Semiquantitative Dynamic and Intrinsic Susceptibility-Weighted MRI Parameters in the Benign and Malignant Human Prostate [J].
Alonzi, Roberto ;
Taylor, N. Jane ;
Stirling, J. James ;
d'Arcy, James A. ;
Collins, David J. ;
Saunders, Michele I. ;
Hoskin, Peter J. ;
Padhani, Anwar R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (01) :155-164
[2]   ESUR prostate MR guidelines 2012 [J].
Barentsz, Jelle O. ;
Richenberg, Jonathan ;
Clements, Richard ;
Choyke, Peter ;
Verma, Sadhna ;
Villeirs, Geert ;
Rouviere, Olivier ;
Logager, Vibeke ;
Futterer, Jurgen J. .
EUROPEAN RADIOLOGY, 2012, 22 (04) :746-757
[3]  
BATTEGAY EJ, 1995, J MOL MED, V73, P333
[4]  
Casas H S, 2014, P INT SOC MAGN RESON, V2, P1145
[5]   Washout gradient in dynamic contrast-enhanced MRI is associated with tumor aggressiveness of prostate cancer [J].
Chen, Yu-Jen ;
Chu, Woei-Chyn ;
Pu, Yeong-Shiau ;
Chueh, Shih-Chieh ;
Shun, Chia-Tung ;
Tseng, Wen-Yih Isaac .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (04) :912-919
[6]   Diagnosis of relevant prostate cancer using supplementary cores from magnetic resonance imaging-prompted areas following multiple failed biopsies [J].
Costa, Daniel N. ;
Bloch, B. Nicolas ;
Yao, David F. ;
Sanda, Martin G. ;
Ngo, Long ;
Genega, Elizabeth M. ;
Pedrosa, Ivan ;
DeWolf, William C. ;
Rofsky, Neil M. .
MAGNETIC RESONANCE IMAGING, 2013, 31 (06) :947-952
[7]   MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results [J].
de Bazelaire, CMJ ;
Duhamel, GD ;
Rofsky, NM ;
Alsop, DC .
RADIOLOGY, 2004, 230 (03) :652-659
[8]   Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT [J].
Driscoll, B. ;
Keller, H. ;
Coolens, C. .
MEDICAL PHYSICS, 2011, 38 (08) :4866-4880
[9]   A Microfabricated Phantom for Quantitative MR Perfusion Measurements: Validation of Singular Value Decomposition Deconvolution Method [J].
Ebrahimi, Behzad ;
Swanson, Scott D. ;
Chupp, Timothy E. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (11) :2730-2736
[10]   WHAT IS THE EVIDENCE THAT TUMORS ARE ANGIOGENESIS DEPENDENT [J].
FOLKMAN, J .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1990, 82 (01) :4-6