Evaluation of detectors for acquisition of pristine depth-dose curves in pencil beam scanning

被引:0
作者
Baeumer, Christian [1 ]
Koska, Benjamin [1 ]
Lambert, Jamil [1 ]
Timmermann, Beate [1 ,2 ]
Mertens, Thierry [3 ]
Talla, Patrick Takoukam [3 ]
机构
[1] Westdeutsch Protonentherapiezentrum Essen WPE Gmb, Essen, Germany
[2] Univ Hosp Essen, Clin Particle Therapy, West German Canc Ctr WTZ, Essen, Germany
[3] IBA Dosimetry, Schwarzenbruck, Germany
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2015年 / 16卷 / 06期
关键词
proton therapy; particle therapy; PBS; pencil beam scanning; integral depth-dose curves; multilayer ionization chambers; IONIZATION-CHAMBER; PROTON; THERAPY; DOSIMETRY; PROFILES; SYSTEM; MODEL;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Acquisition of quasi-monoenergetic ("pristine") depth-dose curves is an essential task in the frame of commissioning and quality assurance of a proton therapy treatment head. For pencil beam scanning delivery modes this is often accomplished by measuring the integral ionization in a plane perpendicular to the axis of an unscanned beam. We focus on the evaluation of three integral detectors: two of them are plane-parallel ionization chambers with an effective radius of 4.1 cm and 6.0 cm, respectively, mounted in a scanning water phantom. The third integral detector is a 6.0 cm radius multilayer ionization chamber. The experimental results are compared with the corresponding measurements under broad field conditions, which are performed with a small radius plane-parallel chamber and a small radius multilayer ionization chamber. We study how a measured depth-dose curve of a pristine proton field depends on the detection device, by evaluating the shape of the depth-dose curve, the relative charge collection efficiency, and intercomparing measured ranges. Our results show that increasing the radius of an integral chamber from 4.1 cm to 6.0 cm increases the collection efficiency by 0%-3.5% depending on beam energy and depth. Ranges can be determined by the large electrode multilayer ionization chamber with a typical uncertainty of 0.4 mm on a routine basis. The large electrode multilayer ionization chamber exhibits a small distortion in the Bragg Peak region. This prohibits its use for acquisition of base data, but is tolerable for quality assurance. The good range accuracy and the peak distortion are characteristics of the multilayer ionization chamber design, as shown by the direct comparison with the small electrode counterpart.
引用
收藏
页码:151 / 163
页数:13
相关论文
共 21 条
  • [1] Battistoni G, 2007, AIP CONF PROC, V896, P31, DOI 10.1063/1.2720455
  • [2] BICHSEL H, 1992, NUCL INSTRUM METH B, V66, P345
  • [3] A dosimetry system for fast measurement of 3D depth-dose profiles in charged-particle tumor therapy with scanning techniques
    Brusasco, C
    Voss, B
    Schardt, D
    Krämer, M
    Kraft, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 168 (04) : 578 - 592
  • [4] Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning
    Courtois, C.
    Boissonnat, G.
    Brusasco, C.
    Colin, J.
    Cussol, D.
    Fontbonne, J. M.
    Marchand, B.
    Mertens, T.
    de Neuter, S.
    Peronnel, J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 736 : 112 - 117
  • [5] Quality assurance of proton beams using a multilayer ionization chamber system
    Dhanesar, Sandeep
    Sahoo, Narayan
    Kerr, Matthew
    Taylor, M. Brad
    Summers, Paige
    Zhu, X. Ronald
    Poenisch, Falk
    Gillin, Michael
    [J]. MEDICAL PHYSICS, 2013, 40 (09)
  • [6] Ferrari A., 2005, Technical Report SLAC-R-773
  • [7] Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas MD Anderson Cancer Center, Proton Therapy Center, Houston
    Gillin, Michael T.
    Sahoo, Narayan
    Bues, Martin
    Ciangaru, George
    Sawakuchi, Gabriel
    Poenisch, Falk
    Arjomandy, Bijan
    Martin, Craig
    Titt, Uwe
    Suzuki, Kazumichi
    Smith, Alfred R.
    Zhu, X. Ronald
    [J]. MEDICAL PHYSICS, 2010, 37 (01) : 154 - 163
  • [8] A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4
    Grevillot, L.
    Bertrand, D.
    Dessy, F.
    Freud, N.
    Sarrut, D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) : 5203 - 5219
  • [9] A novel method for experimental characterization of large-angle scattered particles in scanned carbon-ion therapy
    Hara, Yousuke
    Furukawa, Takuji
    Inaniwa, Taku
    Mizushima, Kota
    Shirai, Toshiyuki
    Noda, Koji
    [J]. MEDICAL PHYSICS, 2014, 41 (02)
  • [10] IAEA, 2004, TRS-398