Rotational Stability of a Single-Piece Hydrophobic Acrylic Intraocular Lens During Removal of Ophthalmic Viscosurgical Devices

被引:9
作者
Hyon, Joon Young [1 ,2 ]
Yeo, Hwan Eok [3 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Ophthalmol, Seoul, South Korea
[2] Seoul Natl Univ, Dept Ophthalmol, Bundang Hosp, Songnam 463707, Gyeonggi, South Korea
[3] Kims Eye Hosp, Dept Ophthalmol, Seoul, South Korea
关键词
CATARACT-SURGERY; VISCOELASTIC SUBSTANCES; ASTIGMATISM CORRECTION; CORNEAL TUNNEL; INCISION; EYES; KERATOTOMY; BIOMETRY;
D O I
10.1016/j.ajo.2009.08.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the effect of cohesive and dispersive ophthalmic viscosurgical device (OVD) on intraoperative rotational stability of the intraocular lens (IOL) with single-piece hydrophobic acrylate platform. DESIGN: Prospective, comparative study. METHODS: This institutional clinical study included 60 eyes of 60 patients who underwent phacoemulsifcation. The patients were equally divided into cohesive OVD (Healon GV; Abbott Medical Optics, Abbott Park, Illinois, USA) group and dispersive OVD (Viscoat; Alcon Laboratories, Fort Worth, Texas, USA) group. Image analysis from the captured digital image was used to measure intraoperative rotation of single-piece hydrophobic acrylate IOL (SA60AT or SA60NT) during OVD removal. RESULTS: Mean intraoperative rotation was 7.42 degrees +/- 4.16 (standard deviation) in dispersive OVD group and 13.08 degrees +/- 5.25 (standard deviation) in cohesive OVD group (P < .001). Twenty-one cases (70%) maintained the alignment within 10 degrees during removal of OVD with dispersive OVD, while only 9 cases (30%) did so with cohesive OVD (P = .005). Counterclockwise rotation was observed in 33% of the all cases. CONCLUSIONS: This study showed that a significant amount of IOL rotation occurred during OVD removal. Intraoperative rotational stability of IOL was greater with Viscoat than with Healon GV. (Am J Ophthalmol 2010; 149:253-257. (C) 2010 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:253 / 257
页数:5
相关论文
共 31 条
[21]   Foldable toric intraocular lens for astigmatism correction in cataract patients [J].
Mendicute, Javier ;
Irigoyen, Cristina ;
Aramberri, Jaime ;
Ondarra, Ana ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04) :601-607
[22]  
Nichamin Louis D, 2006, Ophthalmol Clin North Am, V19, P485
[23]  
Novis C, 2000, Curr Opin Ophthalmol, V11, P47, DOI 10.1097/00055735-200002000-00007
[24]   Postoperative intraocular lens rotation -: A randomized comparison of plate and loop haptic implants [J].
Patel, CK ;
Ormonde, S ;
Rosen, PH ;
Bron, AJ .
OPHTHALMOLOGY, 1999, 106 (11) :2190-2195
[25]   Astigmatism management [J].
Raviv, T ;
Epstein, RJ .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 2000, 40 (03) :183-198
[26]   Astigmatism correction with a foldable toric intraocular lens in cataract patients [J].
Ruhswurm, I ;
Scholz, U ;
Zehetmayer, M ;
Hanselmayer, G ;
Vass, C ;
Skorpik, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (07) :1022-1027
[27]   The influence of viscoelastic substances on the corneal endothelial cell population during cataract surgery:: a prospective study of cohesive and dispersive viscoelastics [J].
Storr-Paulsen, Allan ;
Norregaard, Jens Christian ;
Farik, Ghassan ;
Tarnhoj, Jens .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (02) :183-187
[28]   Toric intraocular lenses for correcting astigmatism in 130 eyes [J].
Sun, XY ;
Vicary, D ;
Montgomery, P ;
Griffiths, M .
OPHTHALMOLOGY, 2000, 107 (09) :1776-1781
[29]   Toric intraocular lens implantation: 100 consecutive cases [J].
Till, JS ;
Yoder, PR ;
Wilcox, TK ;
Spielman, JL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :295-301
[30]   Evaluating the eye's rotational stability during standard photography - Effect on determining the axial orientation of toric intraocular lenses [J].
Viestenz, A ;
Seitz, B ;
Langenbucher, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (03) :557-561