Rotational Stability of a Single-Piece Hydrophobic Acrylic Intraocular Lens During Removal of Ophthalmic Viscosurgical Devices

被引:8
作者
Hyon, Joon Young [1 ,2 ]
Yeo, Hwan Eok [3 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Ophthalmol, Seoul, South Korea
[2] Seoul Natl Univ, Dept Ophthalmol, Bundang Hosp, Songnam 463707, Gyeonggi, South Korea
[3] Kims Eye Hosp, Dept Ophthalmol, Seoul, South Korea
关键词
CATARACT-SURGERY; VISCOELASTIC SUBSTANCES; ASTIGMATISM CORRECTION; CORNEAL TUNNEL; INCISION; EYES; KERATOTOMY; BIOMETRY;
D O I
10.1016/j.ajo.2009.08.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the effect of cohesive and dispersive ophthalmic viscosurgical device (OVD) on intraoperative rotational stability of the intraocular lens (IOL) with single-piece hydrophobic acrylate platform. DESIGN: Prospective, comparative study. METHODS: This institutional clinical study included 60 eyes of 60 patients who underwent phacoemulsifcation. The patients were equally divided into cohesive OVD (Healon GV; Abbott Medical Optics, Abbott Park, Illinois, USA) group and dispersive OVD (Viscoat; Alcon Laboratories, Fort Worth, Texas, USA) group. Image analysis from the captured digital image was used to measure intraoperative rotation of single-piece hydrophobic acrylate IOL (SA60AT or SA60NT) during OVD removal. RESULTS: Mean intraoperative rotation was 7.42 degrees +/- 4.16 (standard deviation) in dispersive OVD group and 13.08 degrees +/- 5.25 (standard deviation) in cohesive OVD group (P < .001). Twenty-one cases (70%) maintained the alignment within 10 degrees during removal of OVD with dispersive OVD, while only 9 cases (30%) did so with cohesive OVD (P = .005). Counterclockwise rotation was observed in 33% of the all cases. CONCLUSIONS: This study showed that a significant amount of IOL rotation occurred during OVD removal. Intraoperative rotational stability of IOL was greater with Viscoat than with Healon GV. (Am J Ophthalmol 2010; 149:253-257. (C) 2010 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:253 / 257
页数:5
相关论文
共 31 条
[1]  
Arshinoff S. A., 1997, P 7 ANN NATL OPHTHAL, P29
[2]   Limbal relaxing incisions with cataract surgery [J].
Budak, K ;
Friedman, NJ ;
Koch, DD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (04) :503-508
[3]   Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses [J].
Chang, David F. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11) :1842-1847
[4]   Early rotational stability of the longer Staar toric intraocular lens - Fifty consecutive cases [J].
Chang, DF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :935-940
[5]   Evaluation of a toric intraocular lens with a Z-haptic [J].
De Silva, Don Julian ;
Ramkissoon, Yashin D. ;
Bloom, Philip A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09) :1492-1498
[6]  
Dong E Y, 2001, Korean J Ophthalmol, V15, P22
[7]  
Grabow HB, 1999, CLEAR CORNEAL LENS SURGERY, P185
[8]   BIOMETRY OF 7,500 CATARACTOUS EYES [J].
HOFFER, KJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1980, 90 (03) :360-368
[9]   Status of toric intraocular lenses [J].
Horn, Jeffrey D. .
CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (01) :58-61
[10]   Refractive astigmatism after oblique clear corneal phacoemulsification cataract incision [J].
Jacobs, BJ ;
Gaynes, BI ;
Deutsch, TA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (07) :949-952