Construction and characterization of the direct piezoelectric immunosensor for atrazine operating in solution

被引:84
|
作者
Steegborn, C
Skladal, P
机构
[1] MASARYK UNIV,DEPT BIOCHEM,CS-61137 BRNO,CZECH REPUBLIC
[2] UNIV BAYREUTH,BIOCHEM LAB,D-95440 BAYREUTH,GERMANY
来源
BIOSENSORS & BIOELECTRONICS | 1997年 / 12卷 / 01期
关键词
immunosensor; piezoelectric biosensor; quartz crystal microbalance; monoclonal antibody; atrazine; competitive assay; kinetic constants;
D O I
10.1016/0956-5663(96)89086-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The direct immunosensor for determination of the herbicide atrazine was studied. The gold electrodes of the piezoelectric quartz crystal were silanized and activated using glutaraldehyde. The bioaffinity ligand atrazine was linked through albumin as a spacer molecule. The modified piezoelectric crystal was placed in a flow cell and all measurements were performed directly in flowing solution. The interaction of the anti atrazine monoclonal antibody (MAb, clone D6F3) with the immobilized atrazine was characterized using both crude ascitic fluid and Protein A-purified MAI, preparates. The association and dissociation rate constants were determined, k(a) = 1.21 x 10(5) M(-1) s(-1) and k(d) = 4.0 x 10(-4) s(-1). The competitive determination of free atrazine was studied using different dilutions (100X, 250X and 1000X) of the ascitic fluid containing MAb. MAb was preincubated with atrazine (concentrations 0.1 mu g/l) for 15 min and the mixture was then introduced to the flow cell. As a signal, either the rate of frequency decrease or the relative change of frequency after the fixed binding period (10 min) was evaluated. As expected, the higher dilutions of MAb provided improved sensitivity for the analyte. For the 1000X diluted ascitic fluid, 0.1 and 1 mu g/l atrazine caused 5 and 30% decreases of the relative binding of MAb, respectively. Repeated use of the crystals was achieved using a 5 min flow of 100 mM NaOH for regeneration. The results obtained seem to be promising for determination of atrazine in drinking water using direct piezoelectric immunosensors. (C) 1996 Elsevier Science Limited
引用
收藏
页码:19 / 27
页数:9
相关论文
共 20 条
  • [1] Development of piezoelectric immunosensors for competitive and direct determination of atrazine
    Pribyl, J
    Hepel, M
    Halámek, J
    Skládal, P
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) : 333 - 341
  • [2] A DIRECT OPTICAL IMMUNOSENSOR FOR ATRAZINE DETECTION
    BRECHT, A
    PIEHLER, J
    LANG, G
    GAUGLITZ, G
    ANALYTICA CHIMICA ACTA, 1995, 311 (03) : 289 - 299
  • [3] Improved direct piezoelectric biosensors operating in liquid solution for the competitive label-free immunoassay of 2,4-dichlorophenoxyacetic acid
    Horacek, J
    Skladal, P
    ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 43 - 50
  • [4] Piezoelectric immunosensor for the direct and rapid detection ofFrancisella tularensis
    M. Pohanka
    P. Skládal
    Folia Microbiologica, 2007, 52 : 325 - 330
  • [5] Piezoelectric immunosensor for direct and rapid detection of staphylococcal enterotoxin A (SEA) at the ng level
    Salmain, Michele
    Ghasemi, Mahsa
    Boujday, Souhir
    Spadavecchia, Jolanda
    Techer, Clarisse
    Val, Florence
    Le Moigne, Vincent
    Gautier, Michel
    Briandet, Romain
    Pradier, Claire-Marie
    BIOSENSORS & BIOELECTRONICS, 2011, 29 (01): : 140 - 144
  • [6] Rapid characterization of monoclonal antibodies using the piezoelectric immunosensor
    Pohanka, Miroslav
    Pavlis, Oto
    Skladal, Petr
    SENSORS, 2007, 7 (03) : 341 - 353
  • [7] A label-free electrochemical immunosensor based on gold nanoparticles for direct detection of atrazine
    Liu, Xia
    Li, Wen-Jin
    Li, Lei
    Yang, Yang
    Mao, Lu-Gang
    Peng, Zhang
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 408 - 414
  • [8] Characterization of immobilization methods for African swine fever virus protein and antibodies with a piezoelectric immunosensor
    Uttenthaler, E
    Kosslinger, C
    Drost, S
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (12): : 1279 - 1286
  • [9] Immobilization of atrazine on gold, a first step towards the elaboration of an indirect immunosensor: characterization by XPS and PM-IRRAS
    Salmain, Michele
    Fischer-Durand, Nathalie
    Roche, Celine
    Pradier, Claire-Marie
    SURFACE AND INTERFACE ANALYSIS, 2006, 38 (09) : 1276 - 1284
  • [10] Biodegradation of atrazine with biochar-mediated functional bacterial biofilm: Construction, characterization and mechanisms
    Zhang, Bo
    Zhang, Jingdan
    Wang, Yuping
    Qu, Jianhua
    Jiang, Zhao
    Zhang, Xu
    Tao, Yue
    Wang, Yifan
    Kang, Zhonghui
    Han, Songting
    Zhang, Jingyi
    Zhang, Ying
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 465