Agreement between anatomical M-mode and tissue Doppler imaging in the assessment of fetal atrioventricular annular plane displacement in uncomplicated pregnancies: A prospective longitudinal study

被引:4
作者
Zanardini, Cristina [1 ]
D'Antonio, Francesco [4 ,5 ]
Hvingel, Bodil [5 ]
Vartun, Ase [4 ]
Prefumo, Federico [1 ]
Flacco, Maria E. [2 ]
Manzoli, Lamberto [3 ]
Acharya, Ganesh [4 ,5 ,6 ,7 ]
机构
[1] Univ Brescia, Dept Obstet & Gynecol, Brescia, Italy
[2] Local Hlth Unit Pescara, Pescara, Italy
[3] Univ Ferrara, Dept Med Sci, Ferrara, Italy
[4] UiT Artic Univ Norway, Fac Hlth Sci, Dept Clin Med, Womens Hlth & Perinatol Res Grp, Tromso, Norway
[5] Univ Hosp North Norway, Dept Obstet & Gynecol, Tromso, Norway
[6] Karolinska Univ Hosp, Karolinska Inst, Dept Clin Sci Intervent & Technol, Stockholm, Sweden
[7] Karolinska Univ Hosp, Ctr Fetal Med, Stockholm, Sweden
关键词
atrioventricular plane systolic excursion; fetal echocardiography; M-mode; tissue Doppler imaging; LONG-AXIS FUNCTION; SYSTOLIC EXCURSION; VELOCITY; CONCORDANCE; STRAIN; FETUS; INDEX;
D O I
10.1111/jog.14068
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim To evaluate the level of agreement between M-mode and pulsed-wave tissue Doppler imaging (PW-TDI) techniques in assessing fetal mitral annular plane systolic excursion (MAPSE), tricuspid annular plane systolic excursion (TAPSE) and septal annular plane systolic excursion (SAPSE) in a low-risk population. Methods This prospective longitudinal study included healthy fetuses assessed from 18 to 40 weeks of gestation. Tricuspid annular plane systolic excursion, MAPSE and SAPSE were measured using anatomical M-mode and PW-TDI. The agreement between the two diagnostic tests was assessed using Bland-Altman analysis. Results Fifty fetuses were included in the final analysis. Mean values of TASPE were higher than that of MAPSE. There was a progressive increase of TAPSE, MAPSE and SAPSE values with advancing gestation. For each parameter assessed, there was an overall good agreement between the measurements obtained with M-mode and PW-TDI techniques. However, the measurements made with M-mode were slightly higher than those obtained with PW-TDI (mean differences: 0.03, 0.05 and 0.03 cm for TAPSE, MAPSE and SAPSE, respectively). When stratifying the analyses by gestational age, the mean values of TAPSE, MAPSE and SAPSE measured with M-Mode were higher compared to those obtained with PW-TDI, although the mean differences between the two techniques tended to narrow with increasing gestation. Tricuspid annular plane systolic excursion, MAPSE and SAPSE measurements were all significantly, positively associated with gestational age (all P < 0.001). Conclusion Fetal atrioventricular annular plane displacement can be assessed with M-mode technique, or with PW-TDI as the velocity-time integral of the myocardial systolic waveform. Atrioventricular annular plane displacement values obtained with M-mode technique are slightly higher than those obtained with PW-TDI.
引用
收藏
页码:2150 / 2157
页数:8
相关论文
共 28 条
  • [1] Measurement of atrioventricular annular plane displacement has been revived: will it prove to be useful in assessing fetal cardiac function?
    Acharya, G.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 42 (02) : 125 - 129
  • [2] Concordance between M-mode, pulsed Tissue Doppler, and colour Tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects
    Ballo, Piercarlo
    Bocelli, Arianna
    Motto, Andrea
    Mondillo, Sergio
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2008, 9 (06): : 748 - 753
  • [3] Agreement between methods of measurement with multiple observations per individual
    Bland, J. Martin
    Altman, Douglas G.
    [J]. JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) : 571 - 582
  • [4] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Rapid assessment of longitudinal systolic left ventricular function using speckle tracking of the mitral annulus
    Buss, Sebastian J.
    Mereles, Derliz
    Emami, Mostafa
    Korosoglou, Grigorios
    Riffel, Johannes H.
    Bertel, Diane
    Schonland, Stefan O.
    Hegenbart, Ute
    Katus, Hugo A.
    Hardt, Stefan E.
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (04) : 273 - 280
  • [7] Right and left ventricular long-axis function in the fetus using angular M-mode
    Carvalho, JS
    O'Sullivan, C
    Shinebourne, EA
    Henein, MY
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (06) : 619 - 622
  • [8] Gestational age- and estimated fetal weight-adjusted reference ranges for myocardial tissue Doppler indices at 24-41 weeks' gestation
    Comas, M.
    Crispi, F.
    Gomez, O.
    Puerto, B.
    Figueras, F.
    Gratacos, E.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 37 (01) : 57 - 64
  • [9] Usefulness of myocardial tissue Doppler vs conventional echocardiography in the evaluation of cardiac dysfunction in early-onset intrauterine growth restriction
    Comas, Montse
    Crispi, Fatima
    Cruz-Martinez, Rogelio
    Maria Martinez, Josep
    Figueras, Francesc
    Gratacos, Eduard
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2010, 203 (01) : 45.e1 - 45.e7
  • [10] Crispi F, 2012, FETAL DIAGNTHER, V32, P7