A novel functional calibration method for real-time elbow joint angles estimation with magnetic-inertial sensors

被引:34
作者
Ligorio, G. [1 ]
Zanotto, D. [2 ]
Sabatini, A. M. [1 ]
Agrawal, S. K. [2 ]
机构
[1] Scuola Super Sant Anna, BioRobot Inst, I-56125 Pisa, Italy
[2] Columbia Univ, Robot & Rehabil Lab, New York, NY 10027 USA
关键词
Elbow joint angles; Functional calibration; Inertial and magnetic sensors; AMBULATORY MEASUREMENT; SHOULDER; MOTION; WRIST;
D O I
10.1016/j.jbiomech.2017.01.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic-inertial measurement units (MIMUs) are often used to measure the joint angles between two body segments. To obtain anatomically meaningful joint angles, each MIMU must be computationally aligned (i.e., calibrated) with the anatomical rotation axes. In this paper, a novel four-step functional calibration method is presented for the elbow joint, which relies on a two-degrees-of-freedom elbow model. In each step, subjects are asked to perform a simple task involving either one-dimensional motions around some anatomical axes or a static posture. The proposed method was implemented on a fully portable wearable system, which, after calibration, was capable of estimating the elbow joint angles in real time. Fifteen subjects participated in a multi-session experiment that was designed to assess accuracy, repeatability and robustness of the proposed method. When compared against an optical motion capture system (OMCS), the proposed wearable system showed an accuracy of about 4 along each degree of freedom. The proposed calibration method was tested against different MIMU mountings, multiple repetitions and non-strict observance of the calibration protocol and proved to be robust against these factors. Compared to previous works, the proposed method does not require the wearer to maintain specific arm postures while performing the calibration motions, and therefore it is more robust and better suited for real-world applications. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:106 / 110
页数:5
相关论文
共 12 条
[1]   An effortless procedure to align the local frame of an inertial measurement unit to the local frame of another motion capture system [J].
Chardonnens, Julien ;
Favre, Julien ;
Aminian, Kamiar .
JOURNAL OF BIOMECHANICS, 2012, 45 (13) :2297-2300
[2]   Soft tissue artefact assessment in humeral axial rotation [J].
Cutti, AG ;
Paolini, G ;
Troncossi, M ;
Cappello, A ;
Davalli, A .
GAIT & POSTURE, 2005, 21 (03) :341-349
[3]   Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors [J].
Cutti, Andrea Giovanni ;
Giovanardi, Andrea ;
Rocchi, Laura ;
Davalli, Angelo ;
Sacchetti, Rinaldo .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (02) :169-178
[4]   Functionally interpretable local coordinate systems for the upper extremity using inertial & magnetic measurement systems [J].
de Vries, W. H. K. ;
Veeger, H. E. J. ;
Cutti, A. G. ;
Baten, C. ;
van der Helm, F. C. T. .
JOURNAL OF BIOMECHANICS, 2010, 43 (10) :1983-1988
[5]   Comparison of anatomical, functional and regression methods for estimating the rotation axes of the forearm [J].
Fraysse, Francois ;
Thewlis, Dominic .
JOURNAL OF BIOMECHANICS, 2014, 47 (14) :3488-3493
[6]  
Kapur P., 2010, 2010 IEEE HAPT S
[7]   Ambulatory measurement of arm orientation [J].
Luinge, H. J. ;
Veltink, P. H. ;
Baten, C. T. M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (01) :78-85
[8]   Detecting Elementary Arm Movements by Tracking Upper Limb Joint Angles With MARG Sensors [J].
Mazomenos, Evangelos B. ;
Biswas, Dwaipayan ;
Cranny, Andy ;
Rajan, Amal ;
Maharatna, Koushik ;
Achner, Josy ;
Klemke, Jasmin ;
Jobges, Michael ;
Ortmann, Steffen ;
Langendorfer, Peter .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (04) :1088-1099
[9]   A marker-based measurement procedure for unconstrained wrist and elbow motions [J].
Schmidt, R ;
Disselhorst-Klug, C ;
Silny, J ;
Rau, G .
JOURNAL OF BIOMECHANICS, 1999, 32 (06) :615-621
[10]   Parameters for modeling the upper extremity [J].
Veeger, HEJ ;
Yu, B ;
An, KN ;
Rozendal, RH .
JOURNAL OF BIOMECHANICS, 1997, 30 (06) :647-652