Analytical methods for the determination of mixtures of bisphenols and derivatives in human and environmental exposure sources and biological fluids. A review

被引:179
作者
Caballero-Casero, N. [1 ]
Lunar, L. [1 ]
Rubio, S. [1 ]
机构
[1] Univ Cordoba, Inst Fine Chem & Nanochem, Dept Analyt Chem, Edificio Anexo Marie Curie,Campus Rabanales, E-14071 Cordoba, Spain
关键词
Bisphenols; Bisphenol diglycidyl ethers; Halogenated bisphenols; Analytical methods; Risk assessment; Chromatography mass spectrometry; A-DIGLYCIDYL ETHER; PERFORMANCE LIQUID-CHROMATOGRAPHY; ENDOCRINE-DISRUPTING CHEMICALS; BAR SORPTIVE EXTRACTION; NOVOLAC GLYCIDYL ETHERS; STAGE MASS-SPECTROMETRY; PERSONAL CARE PRODUCTS; ACID-ESTERS PARABENS; CHLORINATED DERIVATIVES; HUMAN URINE;
D O I
10.1016/j.aca.2015.12.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bisphenol A (BPA) is ubiquitous in humans and the environment. Its potential adverse effects through genomic and non-genomic pathways have fostered BPA replacement by bisphenol analogs that, unfortunately, exert similar adverse effects. Many of these analogs, as well as their derivatives, have already found in humans and the environment and major concerns have arisen over their low dose-and mixture-related effects. This review aims to discuss the characteristics of the main analytical methods reported so far for the determination of mixtures of bisphenol analogs and/or derivatives in human and environmental exposure sources and biological fluids. Approaches followed for removal of background contamination, sample preparation and separation and detection of mixtures of bisphenols and derivatives are critically discussed. Sample treatment is matrix-dependent and common steps include analyte isolation, removal of interferences, evaporation of the extracts and solvent reconstitution. Separation and quantification has been almost exclusively carried out by liquid chromatography tandem mass spectrometry (LC-MS/MS) or gas chromatography mass spectrometry (GCeMS), in the last case prior derivatization, but LC-fluorescence detection has also found some applications. Main characteristics, advantages and drawbacks of these methods will be comparatively discussed. Although at an early stage, some approaches for the assessment of the risk to mixtures of bisphenols, mainly based on the combination of chemical target analysis and toxicity evaluation, have been already applied and they will be here presented. Current knowledge gaps hindering a reliable assessment of human and environmental risk to mixtures of bisphenols and derivatives will be outlined. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 53
页数:32
相关论文
共 145 条
[1]   Allergic contact dermatitis from bisphenol A in PVC gloves [J].
Aalto-Korte, K ;
Alanko, K ;
Henriks-Eckerman, ML ;
Estlander, T ;
Jolanki, R .
CONTACT DERMATITIS, 2003, 49 (04) :202-205
[2]   Quick and simple sample treatment for multiresidue analysis of bisphenols, bisphenol diglycidyl ethers and their derivatives in canned food prior to liquid chromatography and fluorescence detection [J].
Alabi, A. ;
Caballero-Casero, N. ;
Rubio, S. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1336 :23-33
[3]  
[Anonymous], 2009, REPORT EU COMMISSION
[4]  
[Anonymous], 2008, COMB TOX EFF MULT CH
[5]  
[Anonymous], 2002, RISK ASS MIXT PEST S
[6]  
[Anonymous], 2010, JOINT
[7]  
[Anonymous], 2007, QLK4CT200200603
[8]  
[Anonymous], 2009, 2988 ENV COUNC M BRU
[9]  
[Anonymous], 2015, EFSA J, V13, P3978, DOI DOI 10.2903/j.efsa.2015.3978
[10]  
[Anonymous], 2013, ENV OCC HLTH SAF