Optical Performance in ReZoom and Array Multifocal Intraocular Lenses In Vitro

被引:11
作者
Kawamorita, Takushi [1 ,2 ]
Uozato, Hiroshi [1 ,2 ]
Aizawa, Daisuke [3 ]
Kamiya, Kazutaka [3 ]
Shimizu, Kimiya [2 ,3 ]
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Dept Orthopt & Visual Sci, Sagamihara, Kanagawa 2288555, Japan
[2] Kitasato Univ, Grad Sch Med Sci, Dept Ophthalmol & Visual Sci, Sagamihara, Kanagawa 2288555, Japan
[3] Kitasato Univ, Sch Med, Dept Ophthalmol, Sagamihara, Kanagawa 2288555, Japan
关键词
PUPIL SIZE; MODEL; QUALITY; IMAGE;
D O I
10.3928/1081597X-20090422-10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the modulation transfer function (MTF) of two refractive multifocal intraocular lenses (IOLs). METHODS: The ReZoom and Array (AMO) multifocal IOLs were evaluated using the OPAL Vector system (image Science Ltd) and a model eye with a variable aperture (2.1 to 5.5 mm). Modulation transfer functions were evaluated at distant, near, and intermediate (-1.50 diopter defocus) focus lengths. RESULTS: The ReZoom IOL distant focus MTF for a 5.1-mm effective diameter was higher than that of the Array IOL. At intermediate distance, the ReZoom lens showed a slight increase compared with the Array. The near focus MTF for the ReZoom IOL began to increase at an effective diameter of 2.1 mm and remained constant for diameters >3.45 mm. CONCLUSIONS: The ReZoom IOL gave better image quality than the Array, particularly at distant focus. To enhance near vision with the ReZoom lens, the desirable real pupil diameter should be at least 3.45 mm. [J Refract Surg. 2009;25:467-469.] DOI: 10.9999/1081597X-20090422-10
引用
收藏
页码:467 / 469
页数:3
相关论文
共 11 条
[1]  
*AMO, 2006, REZOOM INSTR MAN
[2]   Image quality with multifocal intraocular lenses and the effect of pupil size -: Comparison of refractive and hybrid refractive-diffractive designs [J].
Artigas, Jose M. ;
Menezo, Jose L. ;
Peris, Cristina ;
Felipe, Adelina ;
Diaz-Llopis, Manuel .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) :2111-2117
[3]   Optical performance measurement and night driving simulation of ReSTOR, ReZoom, and Tecnis multifocal intraocular lenses in a model eye [J].
Choi, Junoh ;
Schwiegerling, Jim .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :218-222
[4]   One-year outcomes with new-generation multifocal intraocular lenses [J].
Cillino, Salvatore ;
Casuccio, Alessandra ;
Di Pace, Francesco ;
Morreale, Raffaella ;
Pillitteri, Francesco ;
Cillino, Giovanni ;
Lodato, Gaetano .
OPHTHALMOLOGY, 2008, 115 (09) :1508-1516
[5]   Cataract extraction with multifocal intraocular lens implantation - A multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes [J].
Javitt, JC ;
Steinert, RF .
OPHTHALMOLOGY, 2000, 107 (11) :2040-+
[6]   Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro [J].
Kawamorita, T ;
Uozato, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (12) :2379-2385
[7]  
Lane Stephen S, 2006, Ophthalmol Clin North Am, V19, P89
[8]   PHENOMENOLOGICAL MODEL FOR INTERPRETING THE CLINICAL-SIGNIFICANCE OF THE IN-VITRO OPTICAL TRANSFER-FUNCTION [J].
LANG, AJ ;
LAKSHMINARAYANAN, V ;
PORTNEY, V .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (07) :1600-1610
[9]   Distance and near contrast sensitivity function after multifocal intraocular lens implantation [J].
Montés-Micó, R ;
Alió, JL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) :703-711
[10]   A prospective comparative study of the AMO ARRAY zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lens [J].
Steinert, RF ;
Aker, BL ;
Trentacost, DJ ;
Smith, PJ ;
Tarantino, N .
OPHTHALMOLOGY, 1999, 106 (07) :1243-1255