CRITICAL APPRAISAL OF VOLUMETRIC MODULATED ARC THERAPY IN STEREOTACTIC BODY RADIATION THERAPY FOR METASTASES TO ABDOMINAL LYMPH NODES

被引:61
|
作者
Bignardi, Mario [2 ]
Cozzi, Luca [1 ]
Fogliata, Antonella
Lattuada, Paola [2 ]
Mancosu, Pietro [2 ]
Navarria, Piera [2 ]
Urso, Gaetano [2 ]
Vigorito, Sabrina [2 ]
Scorsetti, Marta [2 ]
机构
[1] Oncol Inst So Switzerland, Dept Radiat Oncol, Med Phys Unit, CH-6504 Bellinzona, Switzerland
[2] Ist Clin Humanitas, Rozzano, Italy
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2009年 / 75卷 / 05期
关键词
RapidArc; Stereotactic body radiation therapy; IMRT; Volumetric modulated are therapy; MONTE-CARLO CALCULATIONS; CLINICAL IMPLEMENTATION; CONFORMAL RADIOTHERAPY; INTENSITY MODULATION; DOSE CALCULATION; LIVER; IMRT; CANCER; TUMORS; LUNG;
D O I
10.1016/j.ijrobp.2009.05.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A planning study was performed comparing volumetric modulated arcs, RapidArc (RA), fixed beam IMRT (IM), and conformal radiotherapy (CRT) with multiple static fields or short conformal arcs in a series of patients treated with hypofractionated stereotactic body radiation therapy (SBRT) for solitary or oligo-metastases from different tumors to abdominal lymph nodes. Methods and Materials: Fourteen patients were included in the study. Dose prescription was set to 45 Gy (mean dose to clinical target volume [CTV]) in six fractions of 7.5 Gy. Objectives for CTV and planning target volume (PTV) were as follows: Dose(min) >95%, Dose(max) <107%. For organs at risk the following objectives were used: Maximum dose to spine <18 Gy; V-15Gy <35% for both kidneys, V-36Gy <1% for duodenum, V36Gy <3% for stomach and small bowel, V-15Gy <(total liver volume - 700 cm(3)) for liver. Dose-volume histograms were evaluated to assess plan quality. Results: Planning objectives on CTV and PTV were achieved by all techniques. Use of RA improved PTV coverage (V-95% = 90.2% +/- 5.2% for RA compared with 82.5% +/- 9.6% and 84.5% +/- 8.2% for CRT and IM, respectively). Most planning objectives for organs at risk were met by all techniques except for the duodenum, small bowel, and stomach, in which the CRT plans exceeded the dose/volume constraints in some patients. The MU/fraction values were as follows: 2186 +/- 211 for RA, 2583 +/- 699 for IM, and 1554 +/- 153 for CRT. Effective treatment time resulted as follows: 3.7 +/- 0.4 min for RA, 10.6 +/- 1.2 min for IM, and 6.3 +/- 0.5 min for CRT. Conclusions: Delivery of SBRT by RA showed improvements in conformal avoidance with respect to standard conformal irradiation. Delivery parameters confirmed logistical advantages of RA, particularly compared with IM. (C) 2009 Elsevier Inc.
引用
收藏
页码:1570 / 1577
页数:8
相关论文
共 50 条
  • [21] Stereotactic body radiation therapy for patients with recurrent pancreatic adenocarcinoma at the abdominal lymph nodes or postoperative stump including pancreatic stump and other stump
    Zeng, Xian-Liang
    Wang, Huan-Huan
    Meng, Mao-Bin
    Wu, Zhi-Qiang
    Song, Yong-Chun
    Zhuang, Hong-Qing
    Qian, Dong
    Li, Feng-Tong
    Zhao, Lu-Jun
    Yuan, Zhi-Yong
    Wang, Ping
    ONCOTARGETS AND THERAPY, 2016, 9 : 3985 - 3992
  • [22] On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery
    Pokhrel, Damodar
    Sood, Sumit
    McClinton, Christopher
    Shen, Xinglei
    Badkul, Rajeev
    Jiang, Hongyu
    Mallory, Matthew
    Mitchell, Mellissa
    Wang, Fen
    Lominska, Christopher
    MEDICAL DOSIMETRY, 2017, 42 (01) : 69 - 75
  • [23] Stereotactic body radiation therapy using a respiratory-gated volumetric-modulated arc therapy technique for small hepatocellular carcinoma
    Jeong, Yuri
    Jung, Jinhong
    Cho, Byungchul
    Kwak, Jungwon
    Jeong, Chiyoung
    Kim, Jong Hoon
    Park, Jin-hong
    Kim, So Yeon
    Shim, Ju Hyun
    Kim, Kang Mo
    Lim, Young-Suk
    Lee, Han Chu
    Yoon, Sang Min
    BMC CANCER, 2018, 18
  • [24] Dosimetric study for spine stereotactic body radiation therapy: magnetic resonance guided linear accelerator versus volumetric modulated arc therapy
    Yadav, Poonam
    Musunuru, Hima B.
    Witt, Jacob S.
    Bassetti, Michael
    Bayouth, John
    Baschnagel, Andrew M.
    RADIOLOGY AND ONCOLOGY, 2019, 53 (03) : 362 - 368
  • [25] Stereotactic Body Radiation Therapy for Sarcoma Pulmonary Metastases
    Asha, Wafa
    Koro, Sami
    Mayo, Zachary
    Yang, Kailin
    Halima, Ahmed
    Scott, Jacob
    Scarborough, Jessica
    Campbell, Shauna R.
    Budd, G. Thomas
    Shepard, Dale
    Stephans, Kevin
    Videtic, Gregory M.
    Shah, Chirag
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2023, 46 (06): : 263 - 270
  • [26] Stereotactic body radiation therapy using a respiratory-gated volumetric-modulated arc therapy technique for small hepatocellular carcinoma
    Yuri Jeong
    Jinhong Jung
    Byungchul Cho
    Jungwon Kwak
    Chiyoung Jeong
    Jong Hoon Kim
    Jin-hong Park
    So Yeon Kim
    Ju Hyun Shim
    Kang Mo Kim
    Young-Suk Lim
    Han Chu Lee
    Sang Min Yoon
    BMC Cancer, 18
  • [27] FusionArc optimization: A hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy
    Matuszak, Martha M.
    Steers, Jennifer M.
    Long, Troy
    McShan, Daniel L.
    Fraass, Benedick A.
    Romeijn, H. Edwin
    Ten Haken, Randall K.
    MEDICAL PHYSICS, 2013, 40 (07)
  • [28] Stereotactic body radiation therapy for spinal metastases
    Lopes, Joana Cardia
    Navarro, Arturo
    Maria Sole, Josep
    Martinez, Merche
    Guedea, Ferran
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2010, 12 (09) : 639 - 642
  • [29] Stereotactic body radiation therapy for spinal metastases
    Joana Cardia Lopes
    Arturo Navarro
    Josep María Solé
    Merche Martínez
    Ferrán Guedea
    Clinical and Translational Oncology, 2010, 12 : 639 - 642
  • [30] Stereotactic body radiation therapy for liver metastases
    Dawood, Omar
    Mahadevan, Anand
    Goodman, Karyn A.
    EUROPEAN JOURNAL OF CANCER, 2009, 45 (17) : 2947 - 2959